Search results for " atom"
showing 10 items of 1526 documents
Searches for lepton number violation and resonances in K± → πμμ decays
2017
The NA48/2 experiment at CERN collected a large sample of charged kaon decays to final states with multiple charged particles in 2003–2004. A new upper limit on the rate of the lepton number violating decay K±→π∓μ±μ± is reported: B(K±→π∓μ±μ±)<8.6×10−11 at 90% CL. Searches for two-body resonances X in K±→πμμ decays (such as heavy neutral leptons N4 and inflatons χ ) are also presented. In the absence of signals, upper limits are set on the products of branching fractions B(K±→μ±N4)B(N4→πμ) and B(K±→π±X)B(X→μ+μ−) for ranges of assumed resonance masses and lifetimes. The limits are in the (10−11,10−9) range for resonance lifetimes below 100 ps.
ODS tērauda izejmateriālu lokālās struktūras analīze izmantojot Ti un Y K-malas rentgenabsorbcijas spektroskopiju
2017
Šajā darbā tika izmantota rentgenstaru absorbcijas spektru analīze oksīdu stiprinātam tēraudam (ODS), kas ir perspektīvs materiāls dažādās jomās, piemēram, saules elektrostacijās, reaktīvos dzinējos, ķīmiskos reaktoros un kodolreaktoros, jo materiālam piemīt tādas īpašības kā laba siltumvadītspēja un zema termiskās izplešanās apvienojumā ar augstu temperatūras izturību, korozijas un radiācijas pretestību. Darbā tiek iegūta informācija par ar dažādām metodēm izgatavotu ODS tēraudu lokālās atomārās struktūras izmaiņu ap itrija (Y) un titāna (Ti) atomiem, analizējot Y un Ti absorbcijas K-malu.
ODS tērauda izejmateriālu lokālās struktūras analīze, izmantojot rentgenabsorbcijas spektroskopiju
2015
Oksīdu stiprināts tērauds (ODS) ir perspektīvs kodolsintēzes reaktoru materiāls, kuram ir lieliska siltumvadītspēja un zema termiskās izplešanās, apvienojumā ar augstu temperatūras izturību, korozijas un radiācijas pretestību. Tamdēļ šo materiālu var izmantot arī daudzos citos pielietojumos, piemēram, saules elektrostacijās, reaktīvos dzinējos, ķīmiskos reaktoros, kā arī ūdeņraža ražošanā. Šajā darbā ar rentgenabsorbcijas spektroskopijas metodi tika analizētas ferīta un austentisko ODS tēraudu lokālās atomārās struktūras izmaiņas ap dzelzs (Fe) un hroma (Cr) atomiem dažādos tēraudu izgatavošanas posmos, analizējot Fe un Cr absorbcijas K-malas spektrus.
Some observations on the use of matrix modifiers in the determination of aluminum by electrothermal atomic absorption spectrophotometry
1989
Abstract Some evidence demonstrating that the use of matrix modifiers is necessary to obtain good calibration lines in the determination of aluminum by graphite furnace atomic absorption spectrophotometry is provided. It was found that the most sensitive results were obtained when Mg(NO 3 ) 2 was used instead of NH 4 H 2 PO 4 .
Epilepsy stages diagnosis by Gabor atom density according to their aspect ratio
2008
During epilepsy seizure Electrocorticogram (ECoG) may change dramatically from a nearly chaotic signal (basal state) into a highly synchronized signal during a seizure, characterized by high amplitude and low frequency, and suddenly go back to the basal sate, making hard to identify them from time series. The epileptic seizure shows some stages as it is evolving, the here studied are: basal, preictal, ictal and posictal. As most of the bioelectrical signal, ECoG is a highly non periodical signal, so the most suitable techniques to analyze them are the Time-Frequency algorithms (T-F), allowing to follow up its frequency evolution through the seizure. Each seizure stage has a set of frequency…
A Monte Carlo-aided design of a modular 241Am-Be neutron irradiator
2013
Monte Carlo studies aimed at designing a modular 241Am-Be neutron irradiator for testing neutron detectors and personal dosimeters and processing large volume samples are reported in this study. The evaluation of the shapes and thicknesses of the moderator and shielding materials was carried out by a MCNP5 Monte Carlo simulation code. The reliability of the simulation was experimentally verified by the activation of gold foils and TLD dosimeter measurements in an irradiation cell placed at the center of the test configuration.
Wpływ warunków prowadzenia eksperymentu na wyniki badań biomonitoringowych z zastosowaniem mchów
2017
Determination of metal concentrations in certified plastic reference materials after small-size autoclave and microwave-assisted digestion followed w…
2017
Abstract The digestion methods for the determination of As, Cd, Cr, Pb, Sb, Sn and Zn concentrations in plastic samples using microwave-assisted digestion (MW-AD) and small-size autoclave digestion was developed. The certified polyethylene, polypropylene, polyvinyl chloride and acrylonitrile butadiene styrene certified reference materials were used in order to find digestion method working properly for several sample matrices. Efficiency of the digestion methods was evaluated by analyzing the residual carbon in digests by TOC analyzer. MW-AD using a mixture of 7 mL of HNO 3 and 3 mL of H 2 O 2 as a digestion solution resulted in excellent recoveries for As, Cd, Pb, Sb and Zn, and were in th…
Nuevos desafíos en el análisis de la composición mineral de los alimentos
2017
El ser humano resulta expuesto a numerosas sustancias químicas que se incorporan a la cadena alimentaria, constituyendo la ingesta a través de la dieta una de las principales vías de entrada en el organismo. Entre estas sustancias, destaca el interés del estudio de elementos altamente tóxicos como por ejemplo arsénico (As), berilio (Be), cadmio (Cd), cromo (Cr VI) plomo (Pb), mercurio (Hg) y níquel (Ni); elementos de menor toxicidad como antimonio (Sb), bario (Ba), cesio (Cs), germanio (Ge), paladio (Pd), teluro (Te), talio (Tl); estaño (Sn), titanio (Ti), y vanadio (V) o elementales esenciales como cobalto (Co), cobre (Cu), hierro (Fe), magnesio (Mg), molibdeno (Mo), selenio (Se), cromo (C…
Oxygen Atom Transfer Catalysis by Dioxidomolybdenum(VI) Complexes of Pyridyl Aminophenolate Ligands
2021
A series of new cationic dioxidomolybdenum(VI) complexes [MoO2(Ln)]PF6 (2-5) with the tripodal tetradentate pyridyl aminophenolate ligands HL2-HL5 have been synthesized and characterized. Ligands HL2-HL4 carry substituents in the 4-position of the phenolate ring, viz. Cl, Br and NO2, respectively, whereas the ligand HL5, N-(2-hydroxy-3,5-di-tert-butylbenzyl)-N,N-bis(2-pyridylmethyl)amine, is a derivative of 3,5-di-tert-butylsalicylaldehyde. X-ray crystal structures of complexes 2, 3 and 5 reveal that they have a distorted octahedral geometry with the bonding parameters around the metal centres being practically similar. Stoichiometric oxygen atom transfer (OAT) properties of 5 with PPh3 wer…