Search results for " beam"

showing 10 items of 1274 documents

Cone-beam computed tomography in lung stereotactic ablative radiation therapy: predictive parameters of early response

2016

To analyze lung lesion volume variations by contouring on cone-beam CT (CBCT) images to evaluate the early predictive parameters of stereotactic ablative radiation therapy (SABR) treatment response.The prescribed dose of SABR was varied according to the tumour site (central or peripheral) and maximum diameter of the lesions by using a strategy of risk-adapted dose prescription with a dose range between 48 and 70 Gy in 3-10 consecutive fractions. For the purpose of the analysis, the gross tumour volume (GTV) was recontoured for each patient at first and last CBCT using two lung levels/windows: (a) -600/1000 HU and (b) -1000/250 HU. Univariate analysis was performed to evaluate a correlation …

ContouringCone beam computed tomographyUnivariate analysismedicine.medical_specialtyLungFull Paperbusiness.industrymedicine.medical_treatmentGeneral MedicineSABR volatility modelEffective dose (radiation)030218 nuclear medicine & medical imagingRadiation therapy03 medical and health sciences0302 clinical medicinemedicine.anatomical_structureNuclear Medicine and Imaging030220 oncology & carcinogenesisAblative caseMedicineRadiology Nuclear Medicine and imagingRadiologyRadiologyNuclear medicinebusinessThe British Journal of Radiology
researchProduct

9 Development of an experimental tool to evaluate normal tissue 3D doses in external-beam radiotherapy

2018

Introduction Recently, cancer treatment improvement enabled an increase in patients’ survival rate. In more than half of the cases, radiotherapy participates in the cure for cancer. The efficacy of this technique is well known but it inevitably delivers doses to normal tissues exposing them to radio-induced complications risks [1] . Moreover, the longer patients’ life expectancy increases the risk of developing long-term complications such as second cancers. Thus, evaluating the risks following cancer treatment involving radiotherapy constitutes a major challenge. In this context, an experimental tool has been developed to evaluate normal tissue doses delivered by the different radiotherapy…

Contouringbusiness.industrymedicine.medical_treatmentBiophysicsGeneral Physics and AstronomyDose profileContext (language use)General MedicineGel dosimetryImaging phantom030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicinePlanned Dose030220 oncology & carcinogenesismedicineRadiology Nuclear Medicine and imagingExternal beam radiotherapyNuclear medicinebusinessRadiation treatment planningPhysica Medica
researchProduct

The simulation of morphology of dissimilar copper–steel electron beam welds using level set method

2010

Abstract In present work, the simulation of morphology and velocity field in dissimilar electron beam welds formed between the metals with limited solubility is described by the example of copper–stainless steel couple. Finite element software COMSOL Multiphysics 3.5 has been employed due to its flexibility in solving of coupled multiphysical problems. The domination of horizontal flows allows reducing the model to two dimensions. Level set method has been used to determine the position of the interface between immiscible components basing on coupled heat transfer and fluid flow pseudo-stationary solution. The evolution of the shape, fluid flow and mixing pattern in function of operational …

ConvectionWork (thermodynamics)Level set methodGeneral Computer ScienceChemistryMultiphysicsGeneral Physics and AstronomyMineralogyGeneral ChemistryMechanicsFinite element methodComputational MathematicsMechanics of MaterialsHeat transferElectron beam weldingFluid dynamicsGeneral Materials ScienceComputational Materials Science
researchProduct

Peculiarities of imaging one- and two-dimensional structures in an emission electron microscope. 1. theory

2000

Local changes in work function cause deviations of the electrical microfield near a sample surface as a result of the uniform accelerating field distribution between the sample (cathode) and the extractor electrode (anode). This results in a change in the electron trajectories. As a consequence, the microscope image shows remarkable changes in position, size, intensity and lateral resolution of distinct details, which can be quantitatively described by the calculations presented here. Analysing these effects in the image gives an opportunity to determine the real lateral size of the observed structures and the distribution of local contact potentials.

Conventional transmission electron microscopeHistologyMicroscopebusiness.industryScanning electron microscopeChemistryMolecular physicsCathodePathology and Forensic Medicinelaw.inventionOpticslawScanning transmission electron microscopyWork functionsense organsElectron microscopeElectron beam-induced depositionbusinessJournal of microscopy
researchProduct

Spatially-multiplexed interferometric microscopy (SMIM): converting a standard microscope into a holographic one

2014

We report on an extremely simple, low cost and highly stable way to convert a standard microscope into a holographic one. The proposed architecture is based on a common-path interferometric layout where the input plane is spatially-multiplexed to allow reference beam transmission in a common light-path with the imaging branch. As consequence, the field of view provided by the layout is reduced. The use of coherent illumination (instead of the broadband one included in the microscope) and a properly placed one-dimensional diffraction grating (needed for the holographic recording) complete the experimental layout. The proposed update is experimentally validated in a regular Olympus BX-60 upri…

Conventional transmission electron microscopeMicroscopeMaterials sciencebusiness.industryComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONHolographyInterferometric microscopyAtomic and Molecular Physics and Opticslaw.inventionInterferometryOpticslawReference beamMicroscopyDigital holographic microscopybusinessOptics Express
researchProduct

Dopant Contrast in Semiconductors as Interpretation Challenge at Imaging by Electrons

2007

Mechanisms responsible for the contrast between differently doped areas in semiconductors, which is observed in electron micrographs, is discussed as regards the key factors determining the sign and magnitude of the contrast. Experimental data obtained by means of the scanning electron microscope (SEM), scanning low energy electron microscope and photoelectron emission microscope are reviewed together with hints following from them for compilation of a model of the contrast mechanism.

Conventional transmission electron microscopeMicroscopeMaterials sciencebusiness.industryMechanical Engineeringtechnology industry and agricultureLow-voltage electron microscopeCondensed Matter Physicslaw.inventionOpticsMechanics of MaterialslawScanning transmission electron microscopyOptoelectronicsGeneral Materials ScienceElectron beam-induced depositionElectron microscopeHigh-resolution transmission electron microscopybusinessEnvironmental scanning electron microscopeMATERIALS TRANSACTIONS
researchProduct

Phase and structural transformations in annealed copper coatings in relation to oxide whisker growth

2015

Abstract We describe structural and phase transformation in copper coatings made of microparticles during heating and annealing in air in the temperature range up to 400 °C. Such thermal treatment is accompanied by intensive CuO nanowhisker growth on the coating surface and the formation of the layered oxide phases (Cu 2 O and CuO) in the coating interior. X-ray diffraction and focused ion beam (FIB) are employed to characterize the multilayer structure of annealed copper coatings. Formation of volumetric defects such as voids and cracks in the coating is demonstrated.

Copper oxideMaterials scienceAnnealing (metallurgy)MetallurgyOxideGeneral Physics and Astronomychemistry.chemical_elementSurfaces and InterfacesGeneral ChemistryThermal treatmentengineering.materialCondensed Matter PhysicsFocused ion beamCopperSurfaces Coatings and Filmschemistry.chemical_compoundchemistryCoatingWhiskerengineeringComposite materialApplied Surface Science
researchProduct

Beam matching with space charge in energy recovery linacs

2019

Abstract Matching with space charge of an Energy-Recovery Linac (ERL) arc into the subsequent RF structure is essential to preserve beam quality. We show how to match beam envelopes and dispersion along the bends and recirculation arcs of an ERL, including space charge forces, in order to adjust the beam to the parameters of the subsequent RF structure. For a qualitative analysis, we show that one can use a beam matrix approach together with the smooth focusing approximation but with longitudinal–transverse coupling. It is also shown that the space-charge-modified dispersion plays a key role for the adjustment of the momentum compaction R 56 required for both the isochronous and the non-iso…

CouplingPhysicsNuclear and High Energy Physicsbusiness.industryMomentum compactionTracking (particle physics)Space chargeLinear particle acceleratorOpticsDispersion (optics)Physics::Accelerator PhysicsLaser beam qualitybusinessInstrumentationBeam (structure)Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

<title>Electronic excitations and defects in fluoroperovskite LiBaF<formula><inf><roman>3</roman></inf></formu…

2003

A survey of the present situation with respect to knowledge of lattice defects, electronic excitations, such as excitons and localized excitons, as well as energy storage and transfer phenomena in LiBaF3 crystals is given. Both phenomenological models and experimental interpretations of optical absorption bands, tentatively associated with F-type (electron) centers created by X-ray or electron irradiation, is reviewed. Interpretation of three radiative processes (super-fast core-valence transitions, slow trapped exciton luminescence and luminescence of structure defects) observed in undoped LiBaF3 crystals is analyzed with respect to practical application. Attention is paid to the behavior …

CrystalCondensed Matter::Materials ScienceMaterials scienceCondensed matter physicsExcitonElectron beam processingRadiative transferIonic bondingElectronLuminescenceBiexcitonSPIE Proceedings
researchProduct

Microchemical surface analysis of historic copper-based coins by the combined use of FIB-FESEM-EDX, OM, FTIR spectroscopy and solid-state electrochem…

2019

[EN] A multi-technique strategy, including microscopy, spectroscopic and electrochemical techniques, is proposed to study thin corrosion layers that form on the surface of historic copper-based coins. An accurate characterisation of this external corrosion layer is important for selecting a suitable conservation and/or restoration treatment. For this purpose, a series of copper-based coins from different historical periods and provenances, which mainly exhibited atmospheric corrosion, was analysed. The morphology of the corrosion layer and the upper core of coins was studied in trenches done on coin surfaces with a focused ion beam gun, coupled to a field emission scanning electron microsco…

CupriteMaterials scienceVoltammetry of microparticlesCoinchemistry.chemical_element02 engineering and technology01 natural sciencesMicroanalysisFocused ion beamAnalytical ChemistryCorrosionlaw.inventionOptical microscopelawHeritage conservationFourier transform infrared spectroscopySpectroscopyFIB-FESEM-EDX010401 analytical chemistryMetallurgy021001 nanoscience & nanotechnologyCopper0104 chemical sciencesField emission microscopyFTIR spectroscopychemistryPINTURAvisual_artvisual_art.visual_art_mediumCorrosion products0210 nano-technologyMicrochemical Journal
researchProduct