Science based calibration for the extraction of 'analyte-specific' HPLC-DAD chromatograms in environmental analysis

2010

Multivariate science based calibration (SBC) has been applied to the resolution of overlapped peaks in liquid chromatography with diode array detection (LC-DAD). Complex river water samples spiked with 11 pharmaceutical substances resulted in poorly resolved chromatograms containing additional peaks from interfering matrix compounds and a change in the background absorbance due to the mobile phase gradient. Applying the present multivariate approach it was possible to resolve all 11 analytes from overlapping peaks, obtaining linear calibration lines (R2 > 0.96). Recovery percentages on spiked samples ranged between 74.6 and 113.5%, which are quite satisfactory taking into account the low co…

AnalyteResolution (mass spectrometry)Adrenergic beta-AntagonistsStatistics as TopicAnalytical chemistryEnvironmentHigh-performance liquid chromatographyAnalytical ChemistryMatrix (chemical analysis)AbsorbanceRiversSCIENCE BASED CALIBRATIONSample preparationLeast-Squares AnalysisElectrodesChromatography High Pressure LiquidAnalgesicsENVIRONMENTAL ANALYSISChromatographyChemistryOtras Ciencias QuímicasExtraction (chemistry)Ciencias QuímicasDrug ResiduesStandard curveHIGH PERFORMANCE LIQUID CHROMATOGRAPHY-DIODE ARRAY DETECTION (HPLC-DAD)CalibrationMultivariate AnalysisEnvironmental PollutantsCIENCIAS NATURALES Y EXACTAS
researchProduct

An innovative approach to manage uncertainties and stock diversity in the EPBD cost-optimal methodology

2018

The EU Energy Performance of Buildings Directive (EPBD) 2010/31/EU is a step in the right direction to promote near zero energy buildings (NZEB) in a step-wise manner, starting with minimum energy performance and cost optimal thresholds for “reference buildings” (RBs) for each category. Nevertheless, a standard method for defining RBs does not exist, which led to a great divergence between MS in the level of detail used to define RBs for the EPBD cost-optimal analysis. Such lack of harmonisation between MS is further evident given the resulting large discrepancies in energy performance indicators even between countries having similar climate. Furthermore, discrepancies of 30% or higher betw…

Architecture and energy conservationZero-energy buildingSettore ING-IND/11 - Fisica Tecnica AmbientaleOperations researchStock modelling EPBD cost-optimal method Bayesian calibration reference zonesEnergy performance indicatorsbusiness.industryComputer scienceBayesian probabilityEnergy performanceEngineering MultidisciplinaryMühendislik Ortak DisiplinlerBuildings -- Energy conservationDirectiveSoftwareStock modellingEPBD cost-optimal methodBayesian calibrationreference zonesBuildings -- Energy conservation -- European Union countriesSustainable buildings -- Design and construction -- StandardsbusinessZoningBuildings -- Thermal propertiesStock (geology)
researchProduct

Techniques for measuring aerosol attenuation using the Central Laser Facility at the Pierre Auger Observatory

2013

The Pierre Auger Observatory in Malargue, Argentina, is designed to study the properties of ultra-high energy cosmic rays with energies above 10(18) eV. It is a hybrid facility that employs a Fluorescence Detector to perform nearly calorimetric measurements of Extensive Air Shower energies. To obtain reliable calorimetric information from the FD, the atmospheric conditions at the observatory need to be continuously monitored during data acquisition. In particular, light attenuation due to aerosols is an important atmospheric correction. The aerosol concentration is highly variable, so that the aerosol attenuation needs to be evaluated hourly. We use light from the Central Laser Facility, lo…

AstronomyDetector alignment and calibration methods (lasers sources particle-beams)01 natural sciencesDetector alignment and calibration methods (laserObservatoryATMOSPHERIC CONDITIONSDetector alignment and calibration methodsInstrumentationcosmic rayMathematical PhysicsHigh Energy Astrophysical Phenomena (astro-ph.HE)Physicsatmospheric monitoring[SDU.ASTR.HE]Sciences of the Universe [physics]/Astrophysics [astro-ph]/High Energy Astrophysical Phenomena [astro-ph.HE]PhysicsData analysiparticle-beams)ComputingMethodologies_DOCUMENTANDTEXTPROCESSINGCentral Laser FacilityFísica nuclearAstrophysics - Instrumentation and Methods for AstrophysicsAstrophysics - High Energy Astrophysical Phenomenasources[PHYS.ASTR.HE]Physics [physics]/Astrophysics [astro-ph]/High Energy Astrophysical Phenomena [astro-ph.HE][PHYS.ASTR.IM]Physics [physics]/Astrophysics [astro-ph]/Instrumentation and Methods for Astrophysic [astro-ph.IM]sourceAuger Experimentaerosols * Authors are listed on the following pagesData analysisFOS: Physical sciencesCosmic rayAuger Experiment; cosmic rays; atmospheric monitoring; aerosolsOpticscosmic raysUltra-high energy cosmic rays. atmospheric monitoring. aerosols0103 physical sciences010306 general physicsInstrumentation and Methods for Astrophysics (astro-ph.IM)Pierre Auger Observatory010308 nuclear & particles physicsbusiness.industryLarge detector systems for particle and astroparticle physicsAttenuationAtmospheric correctionUltra-high energy cosmic rays[SDU.ASTR.IM]Sciences of the Universe [physics]/Astrophysics [astro-ph]/Instrumentation and Methods for Astrophysic [astro-ph.IM]AerosolDetector alignment and calibration methods (lasersAir showerdetector alignment and calibration methods (lasers; sources; particle-beams); large detector systems for particle and astroparticle physics; data analysisExperimental High Energy PhysicsLarge detector systems for particle and astroparticle physicbusinessRAIOS CÓSMICOSaerosolsSYSTEM
researchProduct

Intercomparison of spectroradiometers for global and direct solar irradiance in the visible range.

2003

This paper presents the results of the analysis of the spectral, global, and direct solar irradiance measurements in the visible range (400–700 nm) that were made in the framework of the first Iberian UV–visible (VIS) instruments intercomparison. The instruments used in this spectral range were four spectroradiometers: three Licor 1800s equipped with different receiver optics and one Optronic 754. For the direct solar irradiance measurements the spectroradiometers were equipped with collimators with different fields of view. Parallel studies have been carried out with the data given by the spectroradiometers with their original calibration file and with the same data that is corrected, foll…

Atmospheric ScienceSpectroradiometersRadiació solarbusiness.industryIrradianceOcean EngineeringIn situ calibrationSolar irradianceSpectroradiometerOpticsSolar irradianceVisible rangeRange (statistics)CalibrationEnvironmental scienceIntercomparisonSpectral databusinessRemote sensing
researchProduct

Automatic cell nuclei counting: a protocol to acquire images and to compare results between color and multispectral images

2013

International audience; High-throughput screening in histology and analysis need a necessary automatic cell or nucleus counting. Current methods and systems based on grayscale or color images give results with counting errors. We suggest to use multispectral imaging (with more than three bands) rather than color one for nucleus counting. A traditional acquisition chains uses a source of white light and a CCD camera in addition to the optical microscope. To pass to a multispectral acquisition, we use a Programmable Light Source (PLS) in the place of the white light source. This PLS is capable of generating different wavelengths in the visible spectrum. So, one color image and four multispect…

Automatic cell nuclei detection[ INFO.INFO-TS ] Computer Science [cs]/Signal and Image Processing[INFO.INFO-TS]Computer Science [cs]/Signal and Image Processing[INFO.INFO-TS] Computer Science [cs]/Signal and Image Processingacquisition protocolmultispectral imagingimage calibration[ SPI.SIGNAL ] Engineering Sciences [physics]/Signal and Image processingcolor imaging[SPI.SIGNAL]Engineering Sciences [physics]/Signal and Image processing[SPI.SIGNAL] Engineering Sciences [physics]/Signal and Image processing
researchProduct

Three-Dimensional Calibration for Routine Analyses of Bromide and Nitrate Ions as Indicators of Groundwater Quality in Coastal Territories

2019

Nitrate and bromide ions are generally considered indicators of anthropogenic pollution and seawater intrusion, respectively, in the groundwater of coastal territories. The analysis of these species is generally carried out with routine chromatographic analyses which generally afford partially merged or poorly resolved peaks. In the present paper a simple method for the correct evaluation of their concentration in water is reported. This method does not imply utilization of other instruments or technologies, only the mathematical elaboration of the data obtained from routine analysis of standard solutions containing the two species. Standard binary solutions of nitrate and bromide ions at d…

Bromidespeak separationpoor resolved peaksHealth Toxicology and MutagenesisIon chromatographyAnalytical chemistrylcsh:MedicineChemical010501 environmental sciencesStandard solutionNitrate01 natural sciencesArticleIonPeak separationchemistry.chemical_compoundNitrateGroundwater qualityBromide3D calibration; Bromide; Groundwater quality; Nitrate; Peak separation; Poor resolved peaks; Bromides; Calibration; Environmental Monitoring; Groundwater; Nitrates; Water Pollutants Chemical; Water QualitynitrateWater QualityCalibrationPoor resolved peaksWater PollutantsWater pollutionGroundwater0105 earth and related environmental sciencesbromideNitrates010405 organic chemistrylcsh:RPublic Health Environmental and Occupational Health0104 chemical scienceschemistryPoor resolved peakBromideCalibrationEnvironmental scienceGroundwaterWater Pollutants ChemicalEnvironmental Monitoring3D calibrationInternational Journal of Environmental Research and Public Health
researchProduct

MILES extended: Stellar population synthesis models from the optical to the infrared

2016

We present the first single-burst stellar population models which covers the optical and the infrared wavelength range between 3500 and 50000 Angstrom and which are exclusively based on empirical stellar spectra. To obtain these joint models, we combined the extended MILES models in the optical with our new infrared models that are based on the IRTF (Infrared Telescope Facility) library. The latter are available only for a limited range in terms of both age and metallicity. Our combined single-burst stellar population models were calculated for ages larger than 1 Gyr, for metallicities between [Fe/H] = -0.40 and 0.26, for initial mass functions of various types and slopes, and on the basis …

CAII TRIPLETStellar populationInfraredMetallicityINITIAL MASS FUNCTIONBROWN DWARFSInfrared telescopeFOS: Physical sciencesAstrophysicsAstrophysics::Cosmology and Extragalactic Astrophysics01 natural sciencesAstronomical spectroscopyinfrared: galaxiesATMOSPHERIC PARAMETERS0103 physical sciencesRange (statistics)Astrophysics::Solar and Stellar Astrophysics2.5 MU-MGIANT BRANCH STARS010303 astronomy & astrophysicsinfrared: starsEMPIRICAL CALIBRATIONAstrophysics::Galaxy AstrophysicsPhysics010308 nuclear & particles physicsNear-infrared spectroscopyHIGH-SPECTRAL-RESOLUTIONAstronomy and AstrophysicsEVOLUTIONARY SYNTHESISAstrophysics - Astrophysics of GalaxiesGalaxySpace and Planetary ScienceAstrophysics of Galaxies (astro-ph.GA)NEWTON-TELESCOPE LIBRARYgalaxies: stellar contentAstrophysics::Earth and Planetary Astrophysics
researchProduct

A chamber to test the response of radon detectors to changing environmental conditions.

2011

Radon risk assessment is carried out with accurate measurements with active or passive instrumentation. All radon detectors must be calibrated and tested using a radon chamber containing a known concentration of radon produced by specific sources of 226Ra. Some of the chambers can also be used to test the response of detectors as a function of environmental conditions. In this case, it can be inferred a calibration curve with respect to changing of the parameter considered. For this aim, a new chamber radon was designed and realized to perform both calibration of instruments and to study the detector response in a large range of variation of the environmental parameters (pressure, 700 - 110…

Calibration curveSettore ING-IND/20 - Misure E Strumentazione NucleariInstrumentationNuclear engineeringchemistry.chemical_elementRadoncalibration chamberRadiation MonitoringCalibrationRadon detector calibration radon chamberHumansRadiology Nuclear Medicine and imagingRadon chamberRadiationRadiological and Ultrasound TechnologyDetectorPublic Health Environmental and Occupational HealthHumidityGeneral MedicinechemistryAir Pollutants RadioactiveRadonCalibrationenvironmental conditionEnvironmental scienceRadiation monitoringEnvironmental MonitoringRadiation protection dosimetry
researchProduct

Uncertainty in environmental and hydrological mathematical modelling

2012

The current state of knowledge regarding uncertainties in urban drainage models is poor. This is in part due to the lack of clarity in the way model uncertainty analyses are conducted and how the results are presented and used. There is a need for a common terminology and a conceptual framework for describing and estimating uncertainties in urban drainage models. Practical tools for the assessment of model uncertainties for a range of urban drainage models are also required to be developed. This paper, produced by the International Working Group on Data and Models, which works under the IWA/IAHR Joint Committee on Urban Drainage, is a contribution to the development of a harmonised framewor…

Calibration dataSettore ICAR/03 - Ingegneria Sanitaria-AmbientaleUncertaintieUrban drainage models; Uncertainties; Input data; Calibration data; Sensitivity analysisInput dataSensitivity analysisUrban drainage model
researchProduct

Hyperspectral UAV-Imagery and photogrammetric canopy height model in estimating forest stand variables

2017

Remote sensing using unmanned aerial vehicle (UAV) -borne sensors is currently a highly interesting approach for the estimation of forest characteristics. 3D remote sensing data from airborne laser scanning or digital stereo photogrammetry enable highly accurate estimation of forest variables related to the volume of growing stock and dimension of the trees, whereas recognition of tree species dominance and proportion of different tree species has been a major complication in remote sensing-based estimation of stand variables. In this study the use of UAV-borne hyperspectral imagery was examined in combination with a high-resolution photogrammetric canopy height model in estimating forest v…

Canopy010504 meteorology & atmospheric sciencesCalibration (statistics)hyperspectral imagingvariablesta1172ta11710211 other engineering and technologies02 engineering and technologyUAVsphotogrammetry01 natural sciencesDigital photogrammetryaerial imagerylcsh:Forestryforest inventoryRadiometric calibrationstereo-photogrammetric canopy modelling021101 geological & geomatics engineering0105 earth and related environmental sciencesRemote sensingfotogrammetriata113forestsForest inventoryEcological ModelingHyperspectral imagingmuuttujatForestryradiometric calibrationOtaNanota4112metsätAerial imagerydigital photogrammetryPhotogrammetryEnvironmental sciencelcsh:SD1-669.5Silva Fennica
researchProduct