Search results for " calibration"
showing 10 items of 148 documents
Science based calibration for the extraction of 'analyte-specific' HPLC-DAD chromatograms in environmental analysis
2010
Multivariate science based calibration (SBC) has been applied to the resolution of overlapped peaks in liquid chromatography with diode array detection (LC-DAD). Complex river water samples spiked with 11 pharmaceutical substances resulted in poorly resolved chromatograms containing additional peaks from interfering matrix compounds and a change in the background absorbance due to the mobile phase gradient. Applying the present multivariate approach it was possible to resolve all 11 analytes from overlapping peaks, obtaining linear calibration lines (R2 > 0.96). Recovery percentages on spiked samples ranged between 74.6 and 113.5%, which are quite satisfactory taking into account the low co…
An innovative approach to manage uncertainties and stock diversity in the EPBD cost-optimal methodology
2018
The EU Energy Performance of Buildings Directive (EPBD) 2010/31/EU is a step in the right direction to promote near zero energy buildings (NZEB) in a step-wise manner, starting with minimum energy performance and cost optimal thresholds for “reference buildings” (RBs) for each category. Nevertheless, a standard method for defining RBs does not exist, which led to a great divergence between MS in the level of detail used to define RBs for the EPBD cost-optimal analysis. Such lack of harmonisation between MS is further evident given the resulting large discrepancies in energy performance indicators even between countries having similar climate. Furthermore, discrepancies of 30% or higher betw…
Techniques for measuring aerosol attenuation using the Central Laser Facility at the Pierre Auger Observatory
2013
The Pierre Auger Observatory in Malargue, Argentina, is designed to study the properties of ultra-high energy cosmic rays with energies above 10(18) eV. It is a hybrid facility that employs a Fluorescence Detector to perform nearly calorimetric measurements of Extensive Air Shower energies. To obtain reliable calorimetric information from the FD, the atmospheric conditions at the observatory need to be continuously monitored during data acquisition. In particular, light attenuation due to aerosols is an important atmospheric correction. The aerosol concentration is highly variable, so that the aerosol attenuation needs to be evaluated hourly. We use light from the Central Laser Facility, lo…
Intercomparison of spectroradiometers for global and direct solar irradiance in the visible range.
2003
This paper presents the results of the analysis of the spectral, global, and direct solar irradiance measurements in the visible range (400–700 nm) that were made in the framework of the first Iberian UV–visible (VIS) instruments intercomparison. The instruments used in this spectral range were four spectroradiometers: three Licor 1800s equipped with different receiver optics and one Optronic 754. For the direct solar irradiance measurements the spectroradiometers were equipped with collimators with different fields of view. Parallel studies have been carried out with the data given by the spectroradiometers with their original calibration file and with the same data that is corrected, foll…
Automatic cell nuclei counting: a protocol to acquire images and to compare results between color and multispectral images
2013
International audience; High-throughput screening in histology and analysis need a necessary automatic cell or nucleus counting. Current methods and systems based on grayscale or color images give results with counting errors. We suggest to use multispectral imaging (with more than three bands) rather than color one for nucleus counting. A traditional acquisition chains uses a source of white light and a CCD camera in addition to the optical microscope. To pass to a multispectral acquisition, we use a Programmable Light Source (PLS) in the place of the white light source. This PLS is capable of generating different wavelengths in the visible spectrum. So, one color image and four multispect…
Three-Dimensional Calibration for Routine Analyses of Bromide and Nitrate Ions as Indicators of Groundwater Quality in Coastal Territories
2019
Nitrate and bromide ions are generally considered indicators of anthropogenic pollution and seawater intrusion, respectively, in the groundwater of coastal territories. The analysis of these species is generally carried out with routine chromatographic analyses which generally afford partially merged or poorly resolved peaks. In the present paper a simple method for the correct evaluation of their concentration in water is reported. This method does not imply utilization of other instruments or technologies, only the mathematical elaboration of the data obtained from routine analysis of standard solutions containing the two species. Standard binary solutions of nitrate and bromide ions at d…
MILES extended: Stellar population synthesis models from the optical to the infrared
2016
We present the first single-burst stellar population models which covers the optical and the infrared wavelength range between 3500 and 50000 Angstrom and which are exclusively based on empirical stellar spectra. To obtain these joint models, we combined the extended MILES models in the optical with our new infrared models that are based on the IRTF (Infrared Telescope Facility) library. The latter are available only for a limited range in terms of both age and metallicity. Our combined single-burst stellar population models were calculated for ages larger than 1 Gyr, for metallicities between [Fe/H] = -0.40 and 0.26, for initial mass functions of various types and slopes, and on the basis …
A chamber to test the response of radon detectors to changing environmental conditions.
2011
Radon risk assessment is carried out with accurate measurements with active or passive instrumentation. All radon detectors must be calibrated and tested using a radon chamber containing a known concentration of radon produced by specific sources of 226Ra. Some of the chambers can also be used to test the response of detectors as a function of environmental conditions. In this case, it can be inferred a calibration curve with respect to changing of the parameter considered. For this aim, a new chamber radon was designed and realized to perform both calibration of instruments and to study the detector response in a large range of variation of the environmental parameters (pressure, 700 - 110…
Uncertainty in environmental and hydrological mathematical modelling
2012
The current state of knowledge regarding uncertainties in urban drainage models is poor. This is in part due to the lack of clarity in the way model uncertainty analyses are conducted and how the results are presented and used. There is a need for a common terminology and a conceptual framework for describing and estimating uncertainties in urban drainage models. Practical tools for the assessment of model uncertainties for a range of urban drainage models are also required to be developed. This paper, produced by the International Working Group on Data and Models, which works under the IWA/IAHR Joint Committee on Urban Drainage, is a contribution to the development of a harmonised framewor…
Hyperspectral UAV-Imagery and photogrammetric canopy height model in estimating forest stand variables
2017
Remote sensing using unmanned aerial vehicle (UAV) -borne sensors is currently a highly interesting approach for the estimation of forest characteristics. 3D remote sensing data from airborne laser scanning or digital stereo photogrammetry enable highly accurate estimation of forest variables related to the volume of growing stock and dimension of the trees, whereas recognition of tree species dominance and proportion of different tree species has been a major complication in remote sensing-based estimation of stand variables. In this study the use of UAV-borne hyperspectral imagery was examined in combination with a high-resolution photogrammetric canopy height model in estimating forest v…