Search results for " computed tomography"

showing 10 items of 411 documents

A comparative study of the pharyngeal airway space, measured with cone beam computed tomography, between patients with different craniofacial morphol…

2014

Abstract Purpose The present study aims to determine any existing association between airway dimensions, measured with cone beam computed tomography (CBCT), and the different patient craniofacial morphologies. Material and methods Sixty CBCT (Dental Picasso Master 3D) images, from patients treated at the Orthodontics Master at Valencia University were selected. The program InVivoDental 5.1 was used to visualize sections, analyze three-dimensional images, and perform airway measurements in the three planes of the space. Intra- and interobserver error methods were recorded. After that, measurements at three different levels of the airway (upper, medium, lower) were taken, in both the anteropo…

AdultMalePalate HardCone beam computed tomographyAdolescentClass iiiMalocclusion Angle Class IMandibleMalocclusion Angle Class IIYoung AdultImaging Three-DimensionalImage Processing Computer-AssistedMedicineHumansCraniofacialChildSkull Basebusiness.industryHyoid BoneReproducibility of ResultsVertical DimensionAnatomyrespiratory systemCone-Beam Computed TomographyCross-Sectional StudiesMalocclusion Angle Class IIIOtorhinolaryngologyPharynxSurgeryFemaleOral SurgeryAnatomic LandmarksPalate SoftbusinessAirwayMalocclusionJournal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery
researchProduct

Utility of CT in the diagnosis of pancreatic fistula after pancreaticoduodenectomy in patients with soft pancreas.

2009

OBJECTIVE: The purpose of this study was to evaluate the sensitivity and specificity of routine performance of CT on postoperative day 7 in patients at high risk of pancreatic fistula after pancreaticoduodenectomy. MATERIALS AND METHODS: Two radiologists analyzed images from CT examinations of 50 patients with soft pancreas 7 days after pancreaticoduodenectomy. Pancreatic fistula was defined at CT as a fluid collection close to the pancreaticogastric or pancreaticojejunal anastomosis. Clinicobiologic criteria for the diagnosis of pancreatic fistula were drain output of any measurable volume of fluid on or after postoperative day 3 that had an amylase content more than three times the serum …

AdultMalePancreas Computed Tomographymedicine.medical_specialtyAdolescentmedicine.medical_treatmentIohexolContrast MediaSerum amylaseSensitivity and SpecificityPancreaticoduodenectomyPancreatic FistulaPostoperative ComplicationsPredictive Value of TestsRisk FactorsHospital dischargeMedicineHumansRadiology Nuclear Medicine and imagingIn patientAgedAged 80 and overbusiness.industryPancreatic DiseasesGeneral MedicineMiddle AgedPancreaticoduodenectomymedicine.diseasePancreaticojejunal anastomosismedicine.anatomical_structurePancreatic fistulaPredictive value of testsFemaleRadiologybusinessPancreasTomography X-Ray ComputedSettore MED/36 - Diagnostica Per Immagini E Radioterapia
researchProduct

Influence of soft tissue grafting, orofacial implant position, and angulation on facial hard and soft tissue thickness at immediately inserted and pr…

2018

Background Resorption of hard and soft tissues following immediate implant insertion is frequently reported. Data regarding the influencing factors on facial tissue thickness are rare. Purpose This retrospective study investigated the impact of connective tissue grafting, the orofacial angulation and position of immediately inserted and provisionalized implants on the facial hard and soft tissue thickness in the anterior maxilla within a 1- to 5-year follow-up. Material and methods Implants with the prerequisite of having preoperative and postoperative cone beam computed tomography (CBCT) and a follow-up of 1 to 5 years were included. Facial bone deficiencies were grafted flaplessly with au…

AdultMalePeriodontiumCone beam computed tomographyImmediate Dental Implant LoadingFacial boneAdolescentConnective tissue03 medical and health sciencesYoung Adult0302 clinical medicineAlveolar ProcessMaxillaMedicineHumansBone regenerationGeneral DentistryAgedRetrospective StudiesOrthodonticsbusiness.industryDental Implantation EndosseousMouth MucosaSoft tissue030206 dentistryCone-Beam Computed TomographyMiddle AgedResorptionDental Restoration Temporarymedicine.anatomical_structure030220 oncology & carcinogenesisFacial tissueFemaleImplantOral SurgerybusinessClinical implant dentistry and related research
researchProduct

Clinical and prognostic value of 18F-FDG-PET/CT in restaging of pancreatic cancer

2018

Aim The aim of this retrospective multicentre study was to evaluate the clinical and prognostic effect of fluorine-18-fluorodeoxyglucose (18F-FDG)-PET/computed tomography (CT) in the restaging process of pancreatic cancer (PC). Materials and methods Data from patients treated for primary PC, who underwent18F-FDG-PET/CT for suspicious of disease progression, were collected. Accuracy was assessed employing conventional diagnostic procedures, multidisciplinary team case notes, further18F-FDG-PET/CT scans and/or follow-up. Receiver operating characteristic curve and likelihood ratio (LR+/-) analyses were used for completion of accuracy definition. Progression-free survival (PFS) and overall sur…

AdultMalePrognosioverall survival18F-FDG-PET/CTpancreatic cancer030218 nuclear medicine & medical imaging03 medical and health sciencesdisease progression0302 clinical medicineRetrospective StudieFluorodeoxyglucose F18Positron Emission Tomography Computed TomographyPancreatic cancerrestagingHumansMedicineRadiology Nuclear Medicine and imagingProgression-free survivalRetrospective StudiesAgedNeoplasm StagingReceiver operating characteristicbusiness.industryProportional hazards modelHazard ratioPancreatic NeoplasmArea under the curveRetrospective cohort studyGeneral MedicineMiddle AgedPrognosismedicine.diseaseConfidence intervalPancreatic Neoplasms030220 oncology & carcinogenesisFemalebusinessNuclear medicineprogression-free survivalHumanNuclear Medicine Communications
researchProduct

Airway remodelling assessed by sputum and high resolution computed tomography in asthma and COPD

2004

It is not known whether sputum elastase, metalloproteinase (MMP)-9 and tissue-inhibitor metalloproteinase (TIMP)-1 are related to structural changes of the airways, as assessed by high-resolution computed tomography (HRCT) scan. The relationships between these markers and the magnitude of structural changes of the airways in asthma and chronic obstructive pulmonary disease (COPD) were assessed. Induced sputum and HRCT scan were performed in 30 asthmatics (14 mild and 16 severe) and in 12 patients with COPD. A greater extent of HRCT scan abnormalities was found in COPD than in severe and mild asthmatics. HRCT scan abnormalities correlated with the degree of airway obstruction in COPD and in …

AdultMalePulmonary and Respiratory Medicinemedicine.medical_specialtyPathologyHigh-resolution computed tomographyairway inflammation imagingSettore MED/10 - Malattie Dell'Apparato RespiratorioGastroenterologyStatistics NonparametricPulmonary Disease Chronic ObstructiveInternal medicinemedicineHumansAirway RemodellingAgedAsthmaCOPDTissue Inhibitor of Metalloproteinase-1Pancreatic Elastasemedicine.diagnostic_testbusiness.industryElastaseRespiratory diseaseSputumMiddle Agedrespiratory systemAirway obstructionmedicine.diseaseAsthmaRespiratory Function Testsrespiratory tract diseasesMatrix Metalloproteinase 9SputumFemalemedicine.symptomTomography X-Ray Computedbusiness
researchProduct

Adult exposures from MDCT including multiphase studies: first Italian nationwide survey.

2014

To evaluate the radiation dose in routine multidetector computed tomography (MDCT) examinations in Italian population.This was a retrospective multicentre study included 5,668 patients from 65 radiology departments who had undergone common CT protocols: head, chest, abdomen, chest–abdomen–pelvis (CAP), spine and cardiac. Data included patient characteristics, CT parameters, volumetric CT dose index (CTDIvol) and dose length product (DLP) for each CT acquisition phase. Descriptive statistics were calculated, and a multi-regression analysis was used to outline the main factors affecting exposure.The 75th percentiles of CTDIvol (mGy) and DLP (mGy cm) for whole head were 69 mGy and 1,312 mGy cm…

AdultMaleRadiography Abdominalmedicine.medical_specialtyNationwide survey; Radiation protection; Multidetector CT; Patient dose; Diagnostic reference levelsMultidetector ctNationwide surveyRadiation DosageDiagnostic reference levelsSettore MED/01 - Statistica MedicaSurveys and QuestionnairesMultidetector computed tomographyMultidetector Computed TomographymedicineHumansRadiology Nuclear Medicine and imagingMedical physicscardiovascular diseasesNeuroradiologyRetrospective StudiesRadiation protectionbusiness.industryMultidetector CTRadiation doseGeneral MedicineItalian populationSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)surgical procedures operativeItalycardiovascular systemPatient doseFemaleRadiography ThoracicRadiologybusinessSettore MED/36 - Diagnostica Per Immagini E RadioterapiaNationwide surveyPatient doseEuropean radiology
researchProduct

Comparison of CT and magnetic resonance mDIXON-Quant sequence in the diagnosis of mild hepatic steatosis

2018

Objective: To determine the diagnostic performance of CT in the assessment of mild hepatic steatosis by comparison with MR mDIXON-Quant as a reference standard, and to explore their clinical applications. Methods: In this prospective study 169 volunteers were included. Each subject underwent CT and MR mDIX-ON-Quant examinations. Hepatic steatosis evaluations were performed via liver attenuation alone (CT L), liver to spleen attenuation ratio (CT L/S), difference between liver and spleen attenuation (CT L-S), and MR mDIX-ON-Quant imaging. The effectiveness of CT L, CT L/S, and CT L-S in diagnosing hepatic steatosis severity of ≥5%, ≥10%, and ≥15% was compared, using mDIX-ON-Quant results as …

AdultMaleSensitivity and Specificitynot known030218 nuclear medicine & medical imagingYoung Adult03 medical and health sciences0302 clinical medicineNon-alcoholic Fatty Liver DiseaseMultidetector Computed TomographymedicineHumansRadiology Nuclear Medicine and imagingProspective StudiesProspective cohort studyReference standardsSequence (medicine)Full Papermedicine.diagnostic_testbusiness.industryMagnetic resonance imagingGeneral MedicineMiddle Agedmedicine.diseaseMagnetic Resonance ImagingFemale030211 gastroenterology & hepatologySteatosisNuclear medicinebusinessThe British Journal of Radiology
researchProduct

Pharmacological stress, rest perfusion and delayed enhancement cardiac magnetic resonance identifies very early cardiac involvement in systemic scler…

2017

Objective To evaluate occult cardiac involvement in asymptomatic systemic sclerosis (SSc) patients by pharmacological stress, rest perfusion and delayed enhancement cardiac magnetic resonance (CMR), for a very early identification of patients at higher risk of cardiac-related mortality. Methods Sixteen consecutive patients with definite SSc, fulfilling the American College of Rheumatology/European League Against Rheumatism 2013 classification criteria in less than 1 year from the onset of Raynaud's phenomenon, underwent pharmacological stress, rest perfusion and delayed enhancement CMR. At enrollment, no patient showed signs and/or symptoms suggestive for cardiac involvement. No patient sho…

AdultMalemedicine.medical_specialtyAdenosineHeart diseaseHeart DiseasesVasodilator AgentsContrast MediaMagnetic Resonance Imaging CineAsymptomaticCardiac magnetic resonance imaging with pharmacological stress; Myocardial perfusion defect; Systemic sclerosis; Systemic sclerosis heart involvement; Rheumatology030218 nuclear medicine & medical imaging03 medical and health sciencesMyocardial perfusion imagingCoronary circulation0302 clinical medicineRheumatologyPredictive Value of TestsInternal medicineCoronary CirculationCardiac magnetic resonance imaging with pharmacological stressMultidetector Computed TomographymedicineHumans030203 arthritis & rheumatologyScleroderma Systemicmedicine.diagnostic_testbusiness.industryMicrocirculationMyocardial Perfusion Imagingmedicine.diseaseRheumatologymyocardial perfusion defectSettore MED/16 - Reumatologiamedicine.anatomical_structureEarly DiagnosisVentriclecardiac magnetic resonance imaging with pharmacological streAsymptomatic Diseasessystemic sclerosis heart involvementSystemic sclerosisFemaleRadiologymedicine.symptombusinessPerfusionsystemic sclerosiRheumatism
researchProduct

Characterisation of focal liver lesions undetermined at grey-scale US: contrast-enhanced US versus 64-row MDCT and MRI with liver-specific contrast a…

2010

The aim of this study was to assess the role of contrast-enhanced ultrasonography (CEUS) in the characterisation of focal liver lesions in comparison with multidetector computed tomography (MDCT) and magnetic resonance imaging (MRI) with liver-specific contrast agent.One hundred and eighty-seven focal liver lesions, 91 malignant and 96 benign (mean size 3.2 cm) - proved by biopsy (n=12), histology (n=4), MDCT (n=108), MRI (n=44) MDCT/MRI (n=19) - in 159 patients were studied by CEUS. Two expert radiologists consensually evaluated the contrast-enhancement patterns at CEUS. For each lesion, they assessed: (a) nature (benign, malignant, not assessable), (b) specific diagnosis and (c) need for …

AdultMalemedicine.medical_specialtyAdolescentBiopsymedia_common.quotation_subjectBiopsy Fine-NeedleContrast MediaGrey scaleSensitivity and SpecificityContrast-enhanced sonography Liver Ultrasound Contrast media NeoplasmsPredictive Value of TestsMultidetector computed tomographymedicineHumansContrast (vision)Radiology Nuclear Medicine and imagingcardiovascular diseasesAgedUltrasonographymedia_commonNeuroradiologyAged 80 and overmedicine.diagnostic_testbusiness.industryLiver DiseasesLiver NeoplasmsUltrasoundMagnetic resonance imagingInterventional radiologyGeneral MedicineMiddle AgedMagnetic Resonance ImagingFOCAL LIVER LESION CONTRAST-ENHANCED ULTRASOUNDcardiovascular systemFemaleRadiologyUltrasonographySettore MED/36 - Diagnostica Per Immagini E RadioterapiaTomography X-Ray ComputedbusinessLa radiologia medica
researchProduct

Pulmonary emphysema in cystic fibrosis detected by densitometry on chest multidetector computed tomography.

2013

BackgroundHistopathological studies on lung specimens from patients with cystic fibrosis (CF) and recent results from a mouse model indicate that emphysema may contribute to CF lung disease. However, little is known about the relevance of emphysema in patients with CF. In the present study, we used computationally generated density masks based on multidetector computed tomography (MDCT) of the chest for non-invasive characterization and quantification of emphysema in CF.MethodsVolumetric MDCT scans were acquired in parallel to pulmonary function testing in 41 patients with CF (median age 20.1 years; range 7-66 years) and 21 non-CF controls (median age 30.4 years; range 4-68 years), and subj…

AdultMalemedicine.medical_specialtyAdolescentCystic FibrosisScienceCystic fibrosisPulmonary function testingHounsfield scaleMultidetector computed tomographyMedicineHumansLung volumesChildAgedEmphysemaMultidisciplinaryLungbusiness.industryQCase-control studyRMiddle Agedrespiratory systemmedicine.diseaserespiratory tract diseasesmedicine.anatomical_structureCase-Control StudiesMedicineFemaleRadiologybusinessDensitometryTomography X-Ray ComputedResearch ArticlePLoS ONE
researchProduct