Search results for " computer-assisted"
showing 10 items of 1033 documents
Enhanced field-of-view integral imaging display using multi-Köhler illumination.
2014
A common drawback in 3D integral imaging displays is the appearance of pseudoimages beyond the viewing angle. These pseudoimages appear when the light rays coming from each elemental image are not passing through the corresponding microlens, and a set of barriers must be used to avoid this flipping effect. We present a pure optical arrangement based on Köhler illumination to generate these barriers thus avoiding the pseudoimages. The proposed system does not use additional lenses to project the elemental images, so no optical aberrations are introduced. As an added benefit, Köhler illumination provides a higher contrast 3D display. This work was supported in part by the Plan Nacional I + D …
Quantification of atelectatic lung volumes in two different porcine models of ARDS.
2006
BACKGROUND: Cyclic recruitment during mechanical ventilation contributes to ventilator associated lung injury. Two different pathomechanisms in acute respiratory distress syndrome (ARDS) are currently discussed: alveolar collapse vs persistent flooding of small airways and alveoli. We compare two different ARDS animal models by computed tomography (CT) to describe different recruitment and derecruitment mechanisms at different airway pressures: (i) lavage-ARDS, favouring alveolar collapse by surfactant depletion; and (ii) oleic acid ARDS, favouring alveolar flooding by capillary leakage. METHODS: In 12 pigs [25 (1) kg], ARDS was randomly induced, either by saline lung lavage or oleic acid (…
Accurate estimation of retinal vessel width using bagged decision trees and an extended multiresolution Hermite model.
2012
We present an algorithm estimating the width of retinal vessels in fundus camera images. The algorithm uses a novel parametric surface model of the cross-sectional intensities of vessels, and ensembles of bagged decision trees to estimate the local width from the parameters of the best-fit surface. We report comparative tests with REVIEW, currently the public database of reference for retinal width estimation, containing 16 images with 193 annotated vessel segments and 5066 profile points annotated manually by three independent experts. Comparative tests are reported also with our own set of 378 vessel widths selected sparsely in 38 images from the Tayside Scotland diabetic retinopathy scre…
A comparison among different techniques for human ERG signals processing and classification
2014
A comparison among different techniques for human ERG signals processing and classification ( Articles not published yet, but available online Article in press About articles in press (opens in a new window) ) Barraco, R.a, Persano Adorno, D.a , Brai, M.a, Tranchina, L.b a Dipartimento di Fisica e Chimica, Università di Palermo and CNISM, Viale delle Scienze, Ed. 18, I-90128 Palermo, Italy b Laboratorio di Fisica e Tecnologie Relative - UniNetLab, Università di Palermo, Viale delle Scienze, Ed. 18, I-90128 Palermo, Italy Abstract Feature detection in biomedical signals is crucial for deepening our knowledge about the involved physiological processes. To achieve this aim, many analytic appro…
Wooden panel paintings investigation: An air-coupled ultrasonic imaging approach
2007
In this paper, a method for the study of wooden panel paintings using air-coupled acoustical imaging is presented. In order to evaluate the advantages of the technique, several samples were made to mimic panel paintings along with their typical defects. These specimens were tested by means of both single-sided and through-transmission techniques using planar transducers. Image data were processed by means of a two-dimensional (2-D)-fast Fourier transform-based algorithm to increase the S/N ratio and 2-D representations (C-scans) were generated. The simulated defects were imaged using both configurations. Investigations were undertaken on four antique paintings from a private collection. The…
Mini-COVIDNet: Efficient Lightweight Deep Neural Network for Ultrasound Based Point-of-Care Detection of COVID-19
2021
Lung ultrasound (US) imaging has the potential to be an effective point-of-care test for detection of COVID-19, due to its ease of operation with minimal personal protection equipment along with easy disinfection. The current state-of-the-art deep learning models for detection of COVID-19 are heavy models that may not be easy to deploy in commonly utilized mobile platforms in point-of-care testing. In this work, we develop a lightweight mobile friendly efficient deep learning model for detection of COVID-19 using lung US images. Three different classes including COVID-19, pneumonia, and healthy were included in this task. The developed network, named as Mini-COVIDNet, was bench-marked with …
Adaptive scheduling of acceleration and gyroscope for motion artifact cancelation in photoplethysmography
2022
Background and objective: Recently, various algorithms have been introduced using wrist-worn photo-plethysmography (PPG) to provide high accuracy of instantaneous heart rate (HR) estimation, including during high-intensity exercise. Most studies focus on using acceleration and/or gyroscope signals for the motion artifact (MA) reference, which attenuates or cancels out noise from the MA-corrupted PPG signals. We aim to open and pave the path to find an appropriate MA reference selection for MA cancelation in PPG.Methods: We investigated how the acceleration and gyroscope reference signals correlate with the MAs of the distorted PPG signals and derived both mathematically and experimentally a…
Virtual reality system for planning minimally invasive neurosurgery
2008
Object The authors report on their experience with a 3D virtual reality system for planning minimally invasive neurosurgical procedures. Methods Between October 2002 and April 2006, the authors used the Dextroscope (Volume Interactions, Ltd.) to plan neurosurgical procedures in 106 patients, including 100 with intracranial and 6 with spinal lesions. The planning was performed 1 to 3 days preoperatively, and in 12 cases, 3D prints of the planning procedure were taken into the operating room. A questionnaire was completed by the neurosurgeon after the planning procedure. Results After a short period of acclimatization, the system proved easy to operate and is currently used routinely for pre…
Autostereoscopic Three-Dimensional Neuronavigation to the Sella: Technical Note.
2017
Background A drawback of conventional neuronavigation is the necessity of focusing on two-dimensional images in 3 planes at the same time to determine one's position in the operating field. A solution would be to merge the images into a single three-dimensional (3D) image that mirrors the actual anatomy. The introduction of holographic glassless 3D monitors paved the way to 3D navigation. We present our experience with 3D neuronavigation as exemplified by navigation to and within the sella. Methods Operative planning was conducted with a navigation system using cranial computed tomography and magnetic resonance imaging. The image data sets were processed by the prototype Clariti 3D system t…
Perfusion MRI in normal and abnormal pituitary gland. A preliminary study.
1997
Perfusion MRI (magnetic resonance imaging) of the pituitary gland was performed in 20 healthy volunteers and 63 patients with various lesions involving the pituitary gland. All patients underwent sequential contrast-enhanced MRI using spoiled gradient recalled sequences with high temporal resolution (7 seconds). Four pituitary areas (pituitary stalk, posterior lobe, postero-superior, and antero-inferior adenohypophysis) were tested with a selected region of interest. Maximal contrast percentual variation was calculated. The timing of enhancement in normal patients matched perfectly with normal pituitary vascularization. Abnormal timing in pathological condition was investigated.