Search results for " control system"

showing 10 items of 262 documents

User psychological problems in implementing production control system

2008

Aim of this study was to analyze user psychological problems in implementing new production control system. Our preliminary results suggest that main user psychological problem is rare use effect and learning.

Engineering managementEngineeringKnowledge managementbusiness.industryControl systemProduction control systembusinessProceedings of the 15th European conference on Cognitive ergonomics: the ergonomics of cool interaction
researchProduct

A set of indices to assess the real performance of daylight-linked control systems

2017

Abstract The installation of Building Automation Control Systems (BACs) in general is an effective action to achieve relevant energy savings. Commercial BACs, installed in residential or small offices, often include functions of lighting control, acting as Daylight-Linked Control Systems (DLCSs). Nevertheless, because system performance is strictly dependent on different parameters, BAC’s hardware and software configuration and as well as an inaccurate commissioning do not always allow a perfect execution of the desired tasks; therefore, the system could not work as expected. Moreover, it is well known that energy saving potential is specifically related to the variability of the light envi…

Engineering020209 energyControl (management)Real-time computing0211 other engineering and technologiesBuilding automation02 engineering and technologySet (abstract data type)021105 building & construction0202 electrical engineering electronic engineering information engineeringDaylightElectrical and Electronic EngineeringCivil and Structural EngineeringSoftware configuration managementBuilding automationSettore ING-IND/11 - Fisica Tecnica Ambientalebusiness.industryMechanical EngineeringLighting designBuilding and ConstructionEnergy consumptionDaylight Daylight-linked control systemReliability engineeringSettore ING-IND/33 - Sistemi Elettrici Per L'EnergiaControl systemBenchmark (computing)business
researchProduct

Sequential design of multioverlapping controllers for structural vibration control of tall buildings under seismic excitation

2012

In this article, a computationally effective strategy to obtain multioverlapping controllers via the inclusion principle is applied to design a state-feedback multioverlapping linear-quadratic regulator controller for a 20-story building. The proposed semidecentralized controller only requires state information of neighboring stories to compute the corresponding control actions. This particular information exchange configuration allows introducing a dramatic reduction in the transmission range required for a wireless implementation of the communications system. More specifically, just a one-story transmission range is required by the proposed multioverlapping controller, while a full-buildi…

Engineering:Informàtica::Automàtica i control [Àrees temàtiques de la UPC]Edificis -- Vibració:Enginyeria civil::Materials i estructures [Àrees temàtiques de la UPC]Design strategyFeedback control systemsCommunications systemSeismic protectionLarge-scale systems; Multioverlapping controller; Seismic protection; Structural vibration control; Tall buildings; Wireless control implementation; Control and Systems Engineering; Mechanical EngineeringStructural vibration controlControl d'estructures (Enginyeria)Multioverlapping controllerReduction (complexity):93 Systems Theory; Control [Classificació AMS]Large-scale systemsTall buildingsControl theoryControlWirelessBuildings -- VibrationInformation exchange:93 Systems Theory [Classificació AMS]business.industryMechanical EngineeringWireless control implementationControl engineeringRange (mathematics)Transmission (telecommunications)Control and Systems EngineeringSistemes de control per retroaccióBuildings--VibrationStructural control (Engineering)business
researchProduct

Expert control of DO in the aerobic reactor of an activated sludge process

2001

Abstract An expert control structure is proposed for the control of dissolved oxygen (DO) in a Nitrification Denitrification Biological Excess Phosphorus Removal (NDBEPR) plant to account for the several processes that are influenced by the DO concentration in the aerator. In the scheme a supervisory fuzzy controller determines the set point of an inner DO control loop where an Adaptive Robust Generic Model Control (ARGMC) controller is used. The fuzzy supervisory control has a hierarchical structure. Off-line measurements of biological parameters of influent and effluent streams can be used to periodically update the set points of the fuzzy controllers. The complete control scheme has been…

EngineeringActivated sludgeSupervisory controlControl theorybusiness.industryGeneral Chemical EngineeringControl systemProcess (computing)Fuzzy control systemAerationbusinessFuzzy logicComputer Science ApplicationsComputers & Chemical Engineering
researchProduct

A Laboratory Project for Advanced Control Methods: Control of a Neutralization Process

2003

Abstract A neutralization process is used in a laboratory project for experimenting advanced control techniques. Students may choose among several techniques to experience the behaviour of advanced controller action: adaptive control, GMG control, fuzzy control, self tuning fuzzy control, neural control, neuro-fuzzy control. The experience in advanced self tuning controller based on fuzzy logic is proposed for the control of a neutralization process. The test of a self tuning controller based on fuzzy logic is a very important case because the resulting structure of the controller is easy to implement and modify: the final results are compared with those deriving from the application of a c…

EngineeringAdaptive controlAutomatic controlControl theorybusiness.industrySelf-tuningProcess controlPID controllerControl engineeringFuzzy control systembusinessFuzzy logicIFAC Proceedings Volumes
researchProduct

Adaptive control of hybrid vehicle depending on driving cycle analysis

2013

The most adapted energy management in hybrid electric vehicles depends on the current driving situation. This paper describes a novel control strategy based on driving cycle recognition. A Driving Cycle Recognition Algorithm (DCRA) is firstly presented. It allows recognition between three driving modes: urban, suburban and highway. A real-time control strategy is then defined based on fuzzy logic using DCRA. Results are presented and compared to fuzzy logic controllers parametrized for urban or highway cycles.

EngineeringAdaptive controlbusiness.industryEnergy managementControl (management)Control engineeringFuzzy control systemRecognition algorithmbusinessHybrid vehicleFuzzy logicDriving cycleIECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society
researchProduct

The control of indoor thermal comfort conditions: introducing a fuzzy adaptive controller

2004

The control and the monitoring of indoor thermal conditions represents a pre-eminent task with the aim of ensuring suitable working and living spaces to people. Especially in industrialised countries, in fact, several rules and standards have been recently released in order of providing technicians with suitable design tools and effective indexes and parameters for the checking of the indoor microclimate. Among them, predicted mean vote (PMV) index is often adopted for assessing the thermal comfort conditions of thermal moderate environments. Unfortunately, the PMV index is characterised by non-linear features, that could determine some difficulties when monitoring and controlling HVAC equi…

EngineeringAdaptive controlbusiness.industryMechanical EngineeringControl (management)Thermal comfortPID controllerControl engineeringBuilding and ConstructionFuzzy control systemFuzzy logicControl theoryPMVFuzzy controllerHVACPID controllerElectrical and Electronic EngineeringbusinessAdaptive controllerCivil and Structural Engineering
researchProduct

Control for Networked Control Systems with Time Delays and Packet Dropouts

2013

This paper is concerned with the control issue for a class of networked control systems (NCSs) with packet dropouts and time-varying delays. Firstly, the addressed NCS is modeled as a Markovian discrete-time switched system with two subsystems; by using the average dwell time method, a sufficient condition is obtained for the mean square exponential stability of the closed-loop NCS with a desired disturbance attenuation level. Then, the desired controller is obtained by solving a set of linear matrix inequalities (LMIs). Finally, a numerical example is given to illustrate the effectiveness of the proposed method.

EngineeringArticle Subjectbusiness.industryNetwork packetGeneral Mathematicslcsh:MathematicsGeneral EngineeringMarkov processNetworked control systemlcsh:QA1-939Set (abstract data type)Dwell timesymbols.namesakeExponential stabilityControl theoryComputer Science::Systems and Controllcsh:TA1-2040Control systemsymbolsbusinesslcsh:Engineering (General). Civil engineering (General)Mathematical Problems in Engineering
researchProduct

Control Design for Discrete-Time Fuzzy Systems with Disturbance Inputs via Delta Operator Approach

2013

Published version of an article in the journal: Mathematical Problems in Engineering. Also available from the publisher: http://dx.doi.org/10.1155/2013/724918 Open Access This paper is concerned with the problem of passive control design for discrete-time Takagi-Sugeno (T-S) fuzzy systems with time delay and disturbance input via delta operator approach. The discrete-time passive performance index is established in this paper for the control design problem. By constructing a new type ofLyapunov-Krasovskii function (LKF) in delta domain, and utilizing some fuzzy weighing matrices, a new passive performance condition is proposed for the system under consideration. Based on the condition, a st…

EngineeringArticle Subjectbusiness.industrylcsh:MathematicsGeneral MathematicsGeneral EngineeringControl engineeringFuzzy control systemFunction (mathematics)Delta operatorType (model theory)lcsh:QA1-939Fuzzy logicDomain (software engineering)Discrete time and continuous timelcsh:TA1-2040Control theoryVDP::Matematikk og Naturvitenskap: 400::Matematikk: 410::Anvendt matematikk: 413lcsh:Engineering (General). Civil engineering (General)businessMathematical Problems in Engineering
researchProduct

H∞ fuzzy control of DC-DC converters with input constraint

2012

Published version of an article in the journal: Mathematical Problems in Engineering. Also available from the publisher at: http://dx.doi.org/10.1155/2012/973082 Open access This paper proposes a method for designing H∞ fuzzy control of DC-DC converters under actuator saturation. Because linear control design methods do not take into account the nonlinearity of the system, a T-S fuzzy model and a controller design approach is used. The designed control not only handles the external disturbance but also the saturation of duty cycle. The input constraint is first transformed into a symmetric saturation which is represented by a polytopic model. Stabilization conditions for the H∞ state feedba…

EngineeringArticle Subjectinput constraintsstate feedback systemGeneral Mathematicssimulation examplePlantControl theoryactuator saturationspolytopic modelsexternal disturbancesbusiness.industrylcsh:MathematicsGeneral EngineeringFuzzy control systemConvertersLyapunov approachlcsh:QA1-939VDP::Mathematics and natural science: 400::Mathematics: 410Constraint (information theory)Nonlinear systemDuty cyclelcsh:TA1-2040T-S fuzzy modelscontroller designsState (computer science)businessSaturation (chemistry)lcsh:Engineering (General). Civil engineering (General)linear control design
researchProduct