Control of the Biodegradation of Mixed Wastes in a Continuous Bioreactor by a Type-2 Fuzzy Logic Controller
2009
Abstract Type-2 fuzzy logic control is proposed for nonlinear processes characterized by bifurcations. A control simulation study was conducted for a bioreactor with cell recycle containing phenol and glucose as carbon and energy sources in which a pure culture of Pseudomonas putida is carried out. The model developed by Ajbar [Ajbar, A. (2001). Stability analysis of the biodegradation of mixed wastes in a continuous bioreactor with cell recycle. Water Research, 35 (5), 1201–1208] was used for the simulations. The particular dynamics of the bioreactor, characterized by two saddle-node bifurcations, makes its control difficult, since it may become unstable also for small variations of some p…
Nonlinear control of an activated sludge aeration process: use of fuzzy techniques for tuning PID controllers
1999
In this paper, several tuning algorithms, specifically ITAE, IMC and Cohen and Coon, were applied in order to tune an activated sludge aeration PID controller. Performance results of these controllers were compared by simulation with those obtained by using a nonlinear fuzzy PID controller. In order to design this controller, a trial and error procedure was used to determine, as a function of error at current time and at a previous time, sets of parameters (including controller gain, integral time and derivative time) which achieve satisfactory response of a PID controller actuating over the aeration process. Once these sets of data were obtained, neural networks were used to obtain fuzzy m…
Comparative Study of the Loads Acting on the Operating Cardanic Transmission in the Closed and Open Loop Configurations
2015
On the basis of a comparative study, this paper aims to determine the maximum loads that can occur in operating conditions on the cardanic transmission assembly of motor vehicles in the open or closed loop configurations. The research is conducted under static conditions using finite elements and shows the components with their maximum values obtained in normal operating conditions.
Method for designing PI-type fuzzy controllers for induction motor drives
2001
The paper illustrates a new systematic method for designing PI-type fuzzy controllers for direct field-oriented controlled induction motor drives. First, linear and decoupled models expressing the dynamics of speed, rotor flux, direct and inquadrature stator currents are derived using a nonlinear static compensator and choosing convenient input variables. Then, to guide the dynamics of the above quantities, four conventional PI controllers are designed independently, choosing their bandwidths conveniently. Finally, the input and output scale factors of PI-type fuzzy controllers are derived from the conventional PI controller parameters. The whole drive controller also includes a rotor flux …
A Model-Based Control Strategy for Wind Turbines with Asynchronous Generator
2007
In this paper a model based control methodology is described with reference to a wind turbine for production of alternative energy. The mathematical model of a 600 kW wind turbine is taken into account assuming a well defined profile of the rotor blades. A set of reference angular speeds of the asynchronous generator and a set of reference pitch angles of the blade wind turbine are obtained in order to maximize the extracted wind power and to reach equilibrium conditions between the wind-generated torque and the electric torque of the generator. Finally a PID model based controller is designed and then tested by means of simulation experiments.
On the Impact of Plant Model and Controller Sophistication on Performance of Disturbance Attenuation and System Robustness
2006
In the paper the problem of disturbance attenuation performance in single-loop control system is investigated. Modified MV control strategy with bounded control variance is used as benchmark for both LQG and classically and optimally tuned PID-type controllers. Certain time and frequency domain functions are then examined to further assess the control performance in terms of robustness. It has been shown that as long as the system to be controlled is delay-free, and there is no extreme demand on performance, simple lag-delay system model along with optimally tuned PID control algorithm provides control quality similar to that of LQG controlled original system assuming the same bound on cont…
Researches Regarding the Use of Elctrohydraulic Servosystems at Industrial Robots
2012
This paper presents some researches regarding the use of electro-hydraulic servo-systems in driving the industrial robots, taking into consideration the conditions in which the robots work. The researches conducted upon a particular system, reveal the optimum design elements for obtaining a good behaviour in use, subsequently a good stability in use.
A DC-DC power converter for PV module characterization
2014
In this paper, a standard-compliant electronic load setup for PV module curve detection which features high accuracy, low cost and components count is proposed. The proposed device is based on a DC-DC power converter in open-loop configuration. The proposed system is designed according to regulation constraints in order to achieve high performances in curve detection. Design criteria are discussed. The model is implemented in PSIM environment. Simulation based on data input of a commercial PV Conergy E215P module are carried out under several environmental conditions to show the accuracy of the proposed electronic load. Simulation results are reported.
Identification and robust control of DC/DC converter Hammerstein model
2008
Abstract—This paper deals with model-based robust control of dc/dc power electronic converters. The converter is described by means of a Hammerstein model consisting of the nonlinear static characteristics of the converter and a linear time-invariant (LTI) uncertainmodel whose parameters depend on the actual duty-cycle operating range. This suggests that the controller be designed using robust control techniques. In view of applying robust control, identification of the earlier LTI models is performed by means of simulation experiments, carried out on a converter switching model implemented onMATLAB/SIMULINK environment. Internal model control (IMC) structure is employed for the controller …
Controlling muscular force by functional electrical stimulation using intelligent PID
2015
Functional Electrical Stimulation (FES) appears as a way of extremely promising research today to solve numerous pathology connected to the deficiencies of the nervous system. It is usually used for the rehabilitation of people with neurological disorders. Generally, skeletal muscles are activated by using Constant Frequency Trains (CFTs) with a fixed amplitude and inter-pulse duration. In addition, the systems of electrical stimulation do not adapt the parameters stimulation to obtain a desired force response during the rehabilitation session. The purpose of this study is to adapt automatically the stimulation parameters to the force desired by the clinician with an intelligent PID control…