Search results for " counting"

showing 10 items of 98 documents

Matching emission centers of electrons and photons in current-carrying silver nanoparticle films

2019

Current flow through a nanoparticle film (two-dimensional ensemble of small tunnel-coupled metal particles on a dielectric substrate) is accompanied by electron and photon emission. It has a localized character (originates from emission centers). With an increase in applied voltage, the number of emission centers increases, and with further increase, some of them may burn out. In dark conditions, photon emission centers are visible with a bare eye. To visualize electron emission centers, emission electron microscopy is used. The conducted measurements allow comparison of the number and relative positions of electron and photon emission centers. It is shown that electrons and photons are emi…

Materials sciencePhotonAstrophysics::High Energy Astrophysical PhenomenaPhysics::OpticsNanoparticleAstrophysics::Cosmology and Extragalactic AstrophysicsElectron01 natural sciencesSilver nanoparticlelaw.invention010309 opticsMetalOpticslaw0103 physical sciencesElectrical and Electronic EngineeringEngineering (miscellaneous)Astrophysics::Galaxy Astrophysicsbusiness.industryAtomic and Molecular Physics and OpticsPhoton countingLight intensityvisual_artvisual_art.visual_art_mediumElectron microscopeAtomic physicsbusinessApplied Optics
researchProduct

Real time digital pulse processing for X-ray and gamma ray semiconductor detectors

2013

Abstract Digital pulse processing (DPP) systems, based on direct digitizing and processing of detector signals, have recently been favoured over analog electronics, ensuring higher flexibility, stability, lower dead time and better spectroscopic performance. In this work, we present the performance of a new real time DPP system for X-ray and gamma ray semiconductor detectors. The system is based on a commercial digitizer equipped with a custom DPP firmware, developed by our group, for on-line pulse height and shape analysis. X-ray and gamma ray spectra measurements with cadmium telluride (CdTe) and germanium (Ge) detectors highlight the excellent performance of the system both at low and hi…

Nuclear and High Energy PhysicsComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONchemistry.chemical_elementPulse height analysiGermaniumcomputer.software_genreHigh photon counting rateX-ray and gamma ray spectroscopyOpticsInstrumentationPulse shape analysiPhysicsAnalogue electronicsFirmwarebusiness.industrySettore FIS/01 - Fisica SperimentaleDetectorGamma rayDead timeSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Cadmium telluride photovoltaicsSemiconductor detectorDigital pulse processingchemistryReal time processingbusinesscomputerNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Tritium retention measurements by accelerator mass spectrometry and full combustion of W-coated and uncoated CFC tiles from the JET divertor

2016

Abstract Accelerator mass spectrometry (AMS) and the full combustion method (FCM) followed by liquid scintillation counting were applied to quantitatively determine the tritium retention in the tungsten-coated carbon fibre composites (CFC), in comparison to uncoated CFC tiles from the JET divertor. The tiles were adjacent and exposed to plasma operations between 2007 and 2009. The tritium depth profiles are showing that the tritium retention on the W-coated tile was reduced by a factor of 13.5 in comparison to the uncoated tile whereas the bulk tritium concentration is approximately the same for both tiles.

Nuclear and High Energy PhysicsMaterials scienceanimal structuresgenetic structuresgenetic processesCombustion01 natural sciences010305 fluids & plasmasNuclear physicstritium retention0103 physical sciencesnatural sciencesdivertor tiles010302 applied physicsJet (fluid)DivertorRadiochemistryLiquid scintillation countingPlasmaCondensed Matter PhysicsJETsurface and bulk distributionvisual_artvisual_art.visual_art_mediumTritiumTilesense organsAccelerator mass spectrometry
researchProduct

A test of electric charge conservation with Borexino

2015

Borexino is a liquid scintillation detector located deep underground at the Laboratori Nazionali del Gran Sasso (LNGS, Italy). Thanks to the unmatched radio-purity of the scintillator, and to the well understood detector response at low energy, a new limit on the stability of the electron for decay into a neutrino and a single mono-energetic photon was obtained. This new bound, tau > 6.6 10**28 yr at 90 % C.L., is two orders of magnitude better than the previous limit.

Particle physicsPhysics - Instrumentation and DetectorsOrders of magnitude (temperature)Physics::Instrumentation and DetectorsGeneral Physics and AstronomyFOS: Physical sciencesElectronScintillatorElectric chargeHigh Energy Physics - ExperimentNuclear physicsPhysics and Astronomy (all)High Energy Physics - Experiment (hep-ex)ddc:550Nuclear ExperimentBorexinoComputingMilieux_MISCELLANEOUSPhysics[PHYS]Physics [physics]Liquid scintillation countingDetectorAstrophysics::Instrumentation and Methods for AstrophysicsInstrumentation and Detectors (physics.ins-det)High Energy Physics::ExperimentNeutrino[PHYS.ASTR]Physics [physics]/Astrophysics [astro-ph]
researchProduct

Different methods of cell quantification can lead to different results: a comparison of digital methods using a pilot study of dendritic cells in HIV…

2019

Background Although new digital pathology tools have improved the positive cell quantification, there is a heterogeneity of the quantification methods in the literature. The aim of this study was to evaluate and propose a novel dendritic cells quantification method in squamous cell carcinoma comparing it with a conventional quantification method. Material and Methods Twenty-six squamous cell carcinomas HIV-positive cases affecting the oropharynx, lips and oral cavity were selected. Immunohistochemistry for CD1a, CD83, and CD207 was performed. The immunohistochemical stains were evaluated by automated examination using a positive pixel count algorithm. A conventional quantification method (u…

Pathologymedicine.medical_specialtyCellHIV InfectionsPilot Projects03 medical and health sciences0302 clinical medicineCarcinomamedicineHumansStage (cooking)General DentistryReproducibilityOral Medicine and Pathologybusiness.industryResearchReproducibility of ResultsDigital pathologyDendritic Cells030206 dentistry:CIENCIAS MÉDICAS [UNESCO]medicine.diseaseCell countingmedicine.anatomical_structureOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASCarcinoma Squamous CellMann–Whitney U testImmunohistochemistrySurgerybusinessMedicina Oral Patología Oral y Cirugia Bucal
researchProduct

Comparative imaging of structure and metabolites in tumours.

1991

A novel technique for metabolic imaging using quantitative bioluminescence and single photon imaging was used to measure the distribution of ATP and lactate in two types of human melanoma xenografts with different radiobiologically hypoxic cell fractions (MF: 45 +/- 17% and EE: 6 +/- 3%; mean +/- SD). The tumours were s.c. grown in nude mice and were used for measurement at volumes of 153-3072 mm3. For metabolic imaging the rapidly frozen tumours were serially sectioned, and each cryosection was brought into contact with a frozen bioluminescent enzyme cocktail using a specially designed glass sandwich system. After thawing section and cocktail the luminescence was started, and light was emi…

Pathologymedicine.medical_specialtyMetaboliteTransplantation HeterologousMice NudeBiologychemistry.chemical_compoundMiceAdenosine TriphosphatemedicineBioluminescenceAnimalsHumansRadiology Nuclear Medicine and imagingRadiosensitivityMelanomachemistry.chemical_classificationMice Inbred BALB CRadiological and Ultrasound Technologymedicine.diagnostic_testMelanomaMetabolismmedicine.diseaseMolecular biologyPhoton countingEnzymechemistryPositron emission tomographyLuminescent MeasurementsLactatesInternational journal of radiation biology
researchProduct

Investigation of Solid-Liquid Phase Transition for Sn-54wt%In Alloy by Positron Anihilation Spectroscopy

1995

The peak coincidence counting rate F(T) was measured for Sn-54wt%In alloy at the temperature range from room temperature to 400°C. It was observed that for both heating and cooling run, F(Τ) parameter changes . in the liquid phase. These changes were related to disintegration of SnII microcrystals. From a simple trapping model the defect disintegration enthalpy, H1,, was calculated. For heating and cooling run, the value of H1 was 0.53 ± 0.03 eV and 0.67 ± 0.07 eV, respectively. For well-annealed and cold rolled samples we find only one component, equal 200 ps, in the lifetime spectrum. PACS numbers: 64.70.Dv, 61.72.Cc, 78.70.Bj.

Phase transitionMaterials sciencePositronEnthalpyAlloyengineeringGeneral Physics and AstronomyCoincidence countingTrappingAtmospheric temperature rangeAtomic physicsengineering.materialSpectroscopyActa Physica Polonica A
researchProduct

Advanced Hardware and Software for the Upgrade of Mirror/Prisma Monochromator SPM-2 (Carl Zeiss Jena) for the Measurements of Basic Spectroscopic Pro…

2021

Today's digital electronics and fast computers allow the efficiently processing of large volumes of spectroscopic information, which means the opportunity to reuse and upgrade monochromator with sophisticated optical and mechanical systems being designed and used in the middle of the last century. Particular interest is towards high-resolution prism monochromator. We used such an approach to computerize manual operations of universal mirror monochromator SPM-2, which has changeable quartz, glass, NaCl and KBr crystal prisms. SPM-2 was produced by VEB Carl Zeiss JENA in the early sixties of the last century (in former GDR), and its advanced features were widely used [1]. The current interest…

PhotomultiplierMaterials sciencebusiness.industrychemistry.chemical_elementAtomic spectroscopySpectral linePhoton countinglaw.inventionOpticschemistrylawPrismTelluriumSpectroscopybusinessMonochromator2021 13th International Conference on Measurement
researchProduct

Statistical analysis of time resolved single molecule fluorescence data without time binning

2010

We depict two algorithms to calculate correlation functions from two different time resolved single molecule fluorescence experiments without the need of time binning. Our first procedure allows to calculate the reduced linear dichroism from polarization resolved fluorescence data. Since we process single photon counts instead of time binned data, considerably faster fluctuations of the dichroism can be analyzed than with conventional methods. With our second procedure time resolved fluorescence obtained with a time correlated single photon counting setup can be analyzed with respect to fluorescence lifetime fluctuations. Again this new algorithm processes single photon events making time b…

PhotonChemistryGeneral Physics and AstronomyStatistical analysisPhysical and Theoretical ChemistryDichroismAtomic physicsSingle-molecule experimentPolarization (waves)Linear dichroismFluorescencePhoton countingComputational physicsThe Journal of Chemical Physics
researchProduct

Skin-remitted photon path lengths: experimental study

2020

Skin-remitted picosecond laser pulses were detected at four input-output fiber distances in the spectral range 560-800 nm. After deconvolution procedures, distributions and mean values of the remitted photon path lengths in forearm skin were analyzed.

PhotonMaterials sciencePicosecond laserintegumentary systembusiness.industryPhoton countingnervous system diseasesOpticsimmune system diseasesTemporal resolutionPath (graph theory)Forearm skinDiffuse reflectionDeconvolutionbusinessBiophotonics Congress: Biomedical Optics 2020 (Translational, Microscopy, OCT, OTS, BRAIN)
researchProduct