Distribution of Anterior Chamber Angle Width and Correlation With Age, Refraction, and Anterior Chamber Depth—The Gutenberg Health Study

2016

PURPOSE Scheimpflug imaging allows quantitative analysis of the width of the anterior chamber angle. We report the population-based distribution of the anterior chamber angle width using this noncontact imaging technique and investigate associated factors. METHODS A population-based cross-sectional study was carried out in Germany. A comprehensive ophthalmologic examination including refraction, biometry, and Scheimpflug imaging was performed. Automated measurement of the anterior chamber angle was performed in each anterior chamber quadrant. Exclusion criteria were previous ocular surgery or inadequate image quality. Association analyses were carried out to determine independently associat…

AdultMaleAnterior ChamberOcular surgeryScheimpflug principlePopulationGlaucoma610 Medicine & healthDiagnostic Techniques OphthalmologicalRefraction OcularAnterior chamber angleCornea03 medical and health sciences0302 clinical medicineRisk FactorsGermanyLens CrystallinemedicineHumans610 Medicine & healtheducationAgedSex Characteristicseducation.field_of_studybusiness.industryAge FactorsAstigmatismMiddle Agedmedicine.diseaseRefractionCross-Sectional StudiesOphthalmologic examination030221 ophthalmology & optometryFemaleGlaucoma Angle-ClosureNuclear medicinebusiness030217 neurology & neurosurgeryShallow anterior chamberInvestigative Opthalmology & Visual Science
researchProduct

Ocular biometric repeatability using a new high-resolution swept-source optical coherence tomographer.

2020

To assess the repeatability of ocular biometric parameters using a high-resolution imaging device.74 healthy right eyes were included in this study. Five-repeated measurements were taken with ANTERION high-resolution swept-source optical coherence tomographer (SS-OCT) to measure: corneal thickness (central and at 2, 4 and 6-mm diameters), aqueous depth (AD), lens thickness (LT), anterior chamber volume (ACV), axial length (AL), and pupil (diameter and position). The intrasubject standard deviation (SWe have not found statistically significant differences between repeated measurements (p  0.05). The mean difference for corneal thickness was between -0.08 and 0.28 μm. For AD and LT was 0.004 …

AdultMaleBiometrygenetic structuresBiometricsComputer scienceAnterior ChamberBiomedical EngineeringHigh resolution030204 cardiovascular system & hematologyEye03 medical and health sciencesYoung Adult0302 clinical medicineOpticsOptical coherence tomographyLens CrystallinemedicineHumansAgedmedicine.diagnostic_testbusiness.industryReproducibility of ResultsPupilGeneral MedicineCoherence (statistics)RepeatabilityMiddle Agedeye diseasesSurgeryFemalesense organsbusiness030217 neurology & neurosurgeryTomography Optical CoherenceExpert review of medical devices
researchProduct

Posterior chamber phakic intraocular lenses to correct high myopia: A comparative study between Staar and Adatomed models

2001

ABSTRACT PURPOSE: To determine the feasibility of using posterior chamber phakic intraocular lenses (PIOLs) to treat high myopia, comparing two different models, Staar and Adatomed. METHODS: Twenty-four eyes from 12 patients were studied prospectively. A phakic Staar IOL was implanted in one eye of each patient, and the other eye received a phakic Adatomed IOL. Patients with uveitis or ocular trauma prior to ocular surgery, diabetic retinopathy, or capsular pseudoexfoliation were excluded. The mean preoperative spherical equivalent refraction was -16.00 ± 5.05 D for the Staar group and -15.39 ± 2.83 D for the Adatomed group. Average follow-up was 32.4 months (range, 19 to 46 mo) for the Ada…

AdultMaleIntraocular pressureRefractive errormedicine.medical_specialtyAnterior subcapsular cataractVisual acuitygenetic structuresEye diseasemedicine.medical_treatmentLens Capsule CrystallineVisual AcuityIntraocular lensRefraction OcularPhakic intraocular lensCataractVision disorderPostoperative ComplicationsForeign-Body MigrationLens Implantation IntraocularLens CrystallineMyopiaHumansMedicineIntraocular PressureLenses Intraocularbusiness.industrymedicine.diseaseeye diseasesSurgeryOphthalmologyFeasibility StudiesFemaleSurgerysense organsmedicine.symptombusinessFollow-Up Studies
researchProduct

Short-term Follow-up after Implantation of a Foldable Iris-Fixated Intraocular Lens in Phakic Eyes

2005

Objective To evaluate efficiency, predictability, stability, complications, and patient satisfaction after implantation of a foldable iris-fixated phakic intraocular lens (PIOL) for the correction of myopia. Design Prospective, nonrandomized, comparative (self-controlled) trial. Participants Forty-one eyes of 22 myopic patients aged 18 to 56 years (mean, 36 years) with average sphere of −8.2±2.01 diopters (D; range, −12.25 to −3.75 D) and average preoperative cylinder of −0.90±0.62 D (range, −2.50 to 0.00 D) were enrolled in this prospective study. Methods All eyes underwent implantation of a foldable iris-fixated PIOL with an optical zone of 6.0 mm. The follow-up was 6 months in all cases.…

AdultMaleIntraocular pressuremedicine.medical_specialtyVisual acuityAdolescentgenetic structuresmedicine.medical_treatmentVisual AcuityIrisCell CountIntraocular lensProsthesis DesignPhakic intraocular lensLens Implantation IntraocularOphthalmologyLens CrystallineMyopiaHumansMedicineProspective StudiesIris (anatomy)Intraoperative ComplicationsProspective cohort studyIntraocular PressureDioptreLenses Intraocularbusiness.industryEndothelium CornealMiddle Agedeye diseasesIndirect ophthalmoscopyOphthalmologymedicine.anatomical_structureFemalesense organsmedicine.symptombusinessFollow-Up StudiesOphthalmology
researchProduct

Objective vs Subjective Vault Measurement After Myopic Implantable Collamer Lens Implantation

2009

PURPOSE: To evaluate the relationship between subjective measurements of vault and objective values measured with Visante optical coherence tomography (OCT) in eyes receiving an implantable contact lens (ICL) for myopia correction. DESIGN: Observational cross-sectional study. METHODS: SETTING: Fernández-Vega Ophthalmological Institute, Oviedo, Spain. PATIENTS: Four hundred and fifty-two eyes from 246 patients were elected to be implanted with a Visian ICL V4 (STAAR Surgical Inc, Monrovia, California, USA). OBSERVATION PROCEDURES: Subjective and objective measurements of vault after implantation of ICL. MAIN OUTCOME MEASURES: Subjective vault classified in 5 levels assessed using an optical …

AdultMalePhakic Intraocular Lensesmedicine.medical_specialtyRefractive errorBiometryAdolescentgenetic structuresEye diseasePhakic intraocular lensVision disorderYoung Adult03 medical and health sciences0302 clinical medicineLens Implantation IntraocularOphthalmologyLens CrystallineMyopiamedicineHumansBody Weights and MeasuresImplantable collamer lensScience & Technologybusiness.industryOutcome measuresMiddle Agedmedicine.diseaseeye diseasesOphthalmologyCross-Sectional StudiesVault (architecture)Implantable Contact Lens030221 ophthalmology & optometryOptometryFemalesense organsmedicine.symptombusinessTomography Optical Coherence030217 neurology & neurosurgeryAmerican Journal of Ophthalmology
researchProduct

Phakic intraocular lenses to correct high myopia

2003

Abstract Purpose: To evaluate the feasibility and safety of using phakic intraocular lenses (IOLs) to correct high myopia by comparing 3 IOL models: Adatomed, Staar, and Artisan. Setting: La Fe University Hospital, Department of Ophthalmology, and the Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Methods: In this prospective comparative study, a phakic IOL was implanted in 217 highly myopic eyes (118 patients). Fifty-nine eyes received an Adatomed IOL, 21 eyes a Staar IOL, and 137 eyes an Artisan IOL. The mean preoperative spherical equivalent was −15.39 diopters (D) ± 2.83 (SD), −16.00 ± 5.05 D, and −16.17 ± 2.75 D in the Adatomed, Staar, and Artisan groups, respectively. The …

AdultMaleRefractive errormedicine.medical_specialtyIntraocular pressureAnterior subcapsular cataractVisual acuitygenetic structuresAnterior ChamberEye diseasemedicine.medical_treatmentVisual AcuityIntraocular lensRefraction OcularPhakic intraocular lensCataractPostoperative ComplicationsLens Implantation IntraocularOphthalmologyLens CrystallineMyopiamedicineHumansProspective StudiesIntraocular PressureDioptreLenses Intraocularbusiness.industryMiddle Agedmedicine.diseaseeye diseasesSensory SystemsOphthalmologyFeasibility StudiesFemaleSurgerysense organsSafetymedicine.symptombusinessFollow-Up StudiesJournal of Cataract & Refractive Surgery
researchProduct

Optical quality in eyes with aspheric intraocular lenses and in younger and older adult phakic eyes: comparative study.

2009

To compare ocular higher-order aberrations (HOAs) in eyes with aspheric intraocular lenses (IOL) and in phakic eyes.Department of Ophthalmology, Military Health Service Institute, Warsaw, Poland.Higher-order aberrations with a 5.0 mm pupil and best spectacle-corrected visual acuity (BSCVA) were analyzed in a young phakic group (age 20 to 40 years), older phakic group (age 40 to 60 years), and a pseudophakic group (age 62 to 84 years; SN60WF aspheric IOL).The mean coma was 0.13 microm+/-0.07 (SD) in the younger phakic group, 0.18+/-0.08 microm in the older phakic group, and 0.16+/-0.08 microm in the pseudophakic group; the difference between the 2 phakic groups was statistically significant …

AdultMalemedicine.medical_specialtyAgingVisual acuitygenetic structuresPseudophakiamedicine.medical_treatmentVisual AcuityIntraocular lensProsthesis DesignPupilContrast SensitivityYoung AdultLens Implantation IntraocularOphthalmologyLens CrystallinemedicineHumansAgedComaAged 80 and overLenses IntraocularPhacoemulsificationbusiness.industryPhacoemulsificationMiddle Agedeye diseasesSensory SystemsOphthalmologySpherical aberrationIntraocular lensesOptometrySurgeryFemalesense organsmedicine.symptombusinessPseudophakiaJournal of cataract and refractive surgery
researchProduct

Scheimpflug biometry of the anterior segment after implantation of foldable iris-fixated lenses.

2006

ABSTRACT PURPOSE: To evaluate intraocular dimensions of the anterior segment of myopic phakic eyes after implantation of foldable iris-fixated lenses. METHODS: Seventeen myopic eyes that received a foldable iris-fixated phakic intraocular lens (PIOL) were assessed. Distances between the cornea and the IOLoptic edge and between the IOL optic and the crystalline lens were evaluated using Scheimpf lug photography 3 months postoperatively. RESULTS: The average postoperative distance between the central corneal endothelium and the anterior surface of the IOL was 2.01±0.26 mm. The distance between the corneal endothelium and the peripheral edge of the IOL averaged 1.32±0.18 mm at the 12 o'clock p…

AdultMalemedicine.medical_specialtyCorneal endotheliumBiometrygenetic structuresScheimpflug principleIrisAnterior surfacePhakic intraocular lensRefraction Ocularlaw.inventionLens Implantation IntraocularlawAnterior Eye SegmentCorneaOphthalmologyLens CrystallinemedicineMyopiaPhotographyHumansIris (anatomy)Retrospective StudiesLenses Intraocularbusiness.industrySuture Techniqueseye diseasesLens (optics)Ophthalmologymedicine.anatomical_structureSurgeryFemalesense organsbusinessFollow-Up StudiesJournal of refractive surgery (Thorofare, N.J. : 1995)
researchProduct

Iris-fixated toric phakic intraocular lens: Three-year follow-up

2006

Purpose To evaluate the 3-year safety, efficacy, predictability, and stability of iris-fixated toric phakic intraocular lens (pIOL) implantation for the correction of myopia or hyperopia with astigmatism. Setting Department of Ophthalmology, Johannes Gutenberg University, Mainz, and Department of Ophthalmology, University Clinic, Bochum, Germany. Methods A prospective clinical trial of 40 eyes of 23 patients with high ametropia and astigmatism was conducted. Best spectacle-corrected visual acuity (BSCVA), uncorrected visual acuity, refraction, astigmatism, intraocular pressure, slitlamp biomicroscopy, and indirect ophthalmoscopy were measured preoperatively and postoperatively. Results Of t…

AdultMalemedicine.medical_specialtyIntraocular pressureVisual acuitygenetic structuresmedicine.medical_treatmentVisual AcuityIrisIntraocular lensAstigmatismRefraction OcularPhakic intraocular lensOphthalmoscopyPostoperative ComplicationsLens Implantation IntraocularOphthalmologyLens CrystallineHumansMedicineProspective StudiesIntraoperative ComplicationsIntraocular PressureDioptremedicine.diagnostic_testbusiness.industryAstigmatismMiddle Agedmedicine.diseaseeye diseasesSensory SystemsRefractive Surgical ProceduresOphthalmoscopyToric lensOphthalmologyTreatment OutcomeFemaleSurgerysense organsmedicine.symptombusinessFollow-Up StudiesJournal of Cataract and Refractive Surgery
researchProduct

Comparison of partial coherence interferometry and ultrasound for anterior segment biometry.

2008

To assess the performance of a partial coherence interferometry (PCI)-based device for the determination of anterior segment biometry.Clinica Centrofama, Cartagena, Murcia, Spain.Central corneal thickness (CCT), anterior chamber depth (ACD), and lens thickness (LT) were measured with the ACMaster PCI anterior segment biometer and an Echoscan US-1800 ultrasound (US) biometer/pachymeter with and without cycloplegia. To determine the precision of the instruments, the same examiner took 30 consecutive CCT, ACD, and LT measurements in a single subject under the same conditions and with and without cycloplegia. The same measurements were performed in additional subjects.Twenty-one eyes (16 subjec…

AdultMalemedicine.medical_specialtyMydriaticsMaterials scienceBiometrygenetic structuresLightAnterior ChamberDiagnostic Techniques OphthalmologicalEyeCorneaLens thicknessOphthalmologyLens CrystallinemedicineHumansBody Weights and Measuresbusiness.industryUltrasoundReproducibility of ResultsCycloplegiaPupileye diseasesSensory SystemsSurgeryOphthalmologyInterferometrySoundPartial coherence interferometrySurgeryFemalesense organsmedicine.symptombusinessPartial coherenceJournal of cataract and refractive surgery
researchProduct