Search results for " device"

showing 10 items of 1082 documents

Uptake rates of semipermeable membrane devices (SPMDs) for PCDDs, PCDFs and PCBs in water and sediment.

2000

Uptake rates of several PCDDs, PCDFs and PCBs were measured for semipermeable membrane devices (SPMDs) under controlled conditions in bulk water and sediment. The study was performed at 19 degrees C and 11 degrees C, and water and sediment concentrations were measured during the exposure. Linear uptake rates for specific PCDD/Fs and PCBs in 19 degrees C water varied from 34 to 111 l/m2 day and in 11 degrees C water from 8.8 to 96 l/m2 day for the whole SPMD. Uptake rates at 19 degrees C sediment ranged from 9.0 to 80 mgOC/m2 day and in 11 degrees C sediment, from 3.0 to 31, mgOC/m2 day. Partitioning of the compounds between membrane and lipid was also measured during the linear uptake phase…

Environmental EngineeringPolychlorinated DibenzodioxinsChemistryHealth Toxicology and MutagenesisPublic Health Environmental and Occupational HealthSedimentWaterMembranes ArtificialGeneral MedicineGeneral ChemistryBulk waterDibenzofurans PolychlorinatedPollutionPolychlorinated BiphenylsPermeabilitySoilMembraneSemipermeable membrane devicesEnvironmental chemistryEnvironmental ChemistryPassive detectionSemipermeable membraneWater pollutionBenzofuransChemosphere
researchProduct

Differential Effect on the Determinants of the Late Payments According to the Economic Cycle

2018

From 2004 to 2007, the Spanish financial system grew at a very rapid rate. However, from 2008 to 2012 impairment losses amounted equivalent to 25% of Spanish GDP.The objective of this paper is investigate how have affected the main problems that have suffered the Spanish economy on the late payments on Spanish credit institutions. And to check whether the effect of these problems is different on stages of growth with respect to the stages of crisis.The main results, according the test Chow, confirmed that there is a structural break in the model in 2007. Also the increase in unemployment increases the late payments   and this increase is greater in the stages of growth compared to the stage…

Equity (economics)Rapid ratemedia_common.quotation_subjectStructural breakBancs hipotecarisAturDifferential (mechanical device)PaymentRecessionHabitatge FinançamentUnemploymentPréstecs hipotecaris d'alt riscEconomicsBusiness cycleDemographic economicshealth care economics and organizationsmedia_common
researchProduct

Impact of Transport Costs on International Trade: The Case of Spanish Ceramic Exports

2003

This paper aims to investigate the determinants of maritime and overland transport costs and the role they play in deterring trade across countries. We estimate a transport cost function using data on maritime and overland transport of the ceramic sector (tiles) obtained from interviews held with Spanish logistics operators. We also study the relationship between transport costs and trade and estimate an import demand model for ceramic products. Additionally, we present a discussion on the sensitivity of trade flows and transportation costs to the existence of back-hauling, special conditions for transport and number of reloads.1 The study of modal transport (overland versus maritime) and i…

EstimationCost estimatebusiness.industryEconomics Econometrics and Finance (miscellaneous)TransportationRegression analysisDifferential (mechanical device)International tradePort (computer networking)Bilateral tradeEconomicsProxy (statistics)Trade barrierbusinessMaritime Economics & Logistics
researchProduct

Polymeric microcontainers improve oral bioavailability of furosemide.

2016

Microcontainers with an inner diameter of 223 μm are fabricated using the polymer SU-8, and evaluated in vitro, in situ and in vivo for their application as an advanced oral drug delivery system for the poorly water soluble drug furosemide. An amorphous sodium salt of furosemide (ASSF) is filled into the microcontainers followed by applying a lid using Eudragit L100. It is possible to control the drug release in vitro, and in vitro absorption studies show that the microcontainers are not a hindrance for absorption of ASSF. In situ perfusion studies in rats are performed with ASSF-filled microcontainers coated with Eudragit and compared to a furosemide solution. The absorption rate constant …

Eudragit l100PolymersPharmaceutical ScienceAdministration OralBiological Availability02 engineering and technologyAbsorption (skin)PharmacologyMicro devices030226 pharmacology & pharmacy03 medical and health sciences0302 clinical medicineDrug Delivery SystemsPolymethacrylic AcidsIn vivoDelivery systemsFurosemideOral bioavailabilitymedicineAnimalsHumansIntestinal MucosaRats WistarIntestinal mucusChromatographyChemistryFurosemide021001 nanoscience & nanotechnologyBioavailabilityDrug LiberationMucusOral deliveryEpoxy CompoundsFemaleDelivery systemIntestinal perfusionCaco-2 Cells0210 nano-technologyOral retinoidmedicine.drugInternational journal of pharmaceutics
researchProduct

Colloidal Nanoplatelet/Conducting Polymer Hybrids: Excitonic And Material Properties

2016

WOS:000370678700053 Here we present the first account of conductive polymer/colloidal nanoplatelet hybrids. For this, we developed DEH-PPV-based polymers with two different anchor groups (sulfide and amine) acting as surfactants for CdSe nanoplatelets, which are atomically flat semiconductor nanocrystals. Hybridization of the polymers with the nanoplatelets in the solution phase was observed to cause strong photoluminescence quenching in both materials. Through steady-state photoluminescence and excitation spectrum measurements, photoluminescence quenching was shown to result from dominant exciton dissociation through charge transfer at the polymer/nanoplatelet interfaces that possess a sta…

Excitation spectrumMaterials sciencePhotoluminescenceSulfideDEH-PPV-Based PolymersSulfideExcitonCdSe NanoplateletsNanotechnology02 engineering and technologySurface active agents010402 general chemistryOptoelectronic devices01 natural sciencesDissociation (chemistry)ColloidCharge transferQuenchingHybrid optoelectronic devicesPhysical and Theoretical ChemistryPhotoluminescenceSulfur compoundsAmineSemiconductor nanocrystalsConductive polymerchemistry.chemical_classificationExcited statesBuilding blockesPolymerInterface statesEmission quenching021001 nanoscience & nanotechnology0104 chemical sciencesSurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialsPolymer/Colloidal Nanoplatelet HybridsGeneral EnergyChemical engineeringchemistryExcited stateAnchorsExcitons0210 nano-technologyDissociationConductive polymerPhotoluminescence quenchingExciton dissociation
researchProduct

Vigor F7 projekta ietekme uz redzes funkcijām

2017

Maģistra darbs ir uzrakstīts angļu valodā uz 38 lapām. Tas satur 12 attēlus, 9 tabulas, 26 atsauces uz literatūras avotiem un 4 pielikumus. Galvenais darba mērķis ir nodemonstrēt F7 ierīces ietekmi uz redzes sistēmu un tās funkcijām. Tika veikti divi eksperimenti: Eksperiments I (30 dalībnieki, 10 – 40 g.v.), lai izvērtētu Vigor F7 ierīces ietekmi uz redzes funkcijām; Eksperiments II (20 dalībnieki, sportisti, 14 – 48 g.v.), lai izvērtētu Vigor F7 ierīces ietekmi uz dinamisko iemaņu efektivitāti. Abos eksperimentos novēroja statistiski nozīmīgi atšķirīgus rezultātus gan redzes funkcijām, gan dinamiskajām iemaņām, ja izmantoja F7 ierīci.

F7 devicevisual performancenobles metalsbalanceFizikasports vision
researchProduct

Observation of Geometric Parametric Instability Induced by the Periodic Spatial Self-Imaging of Multimode Waves

2016

Spatio-temporal mode coupling in highly multimode physical systems permits new routes for exploring complex instabilities and forming coherent wave structures. We present here the first experimental demonstration of multiple geometric parametric instability sidebands, generated in the frequency domain through resonant space-time coupling, owing to the natural periodic spatial self-imaging of a multimode quasi-continuous-wave beam in a standard graded-index multimode fiber. The input beam was launched in the fiber by means of an amplified microchip laser emitting sub-nanosecond pulses at 1064 nm. The experimentally observed frequency spacing among sidebands agrees well with analytical predic…

FOS: Physical sciencesGeneral Physics and AstronomyPhysics::Optics01 natural scienceslaw.invention010309 opticsOpticslaw0103 physical sciencesDispersion (optics)010306 general physicsComputingMilieux_MISCELLANEOUSCouplingPhysics[PHYS.PHYS.PHYS-OPTICS]Physics [physics]/Physics [physics]/Optics [physics.optics][ PHYS.PHYS.PHYS-OPTICS ] Physics [physics]/Physics [physics]/Optics [physics.optics]Multi-mode optical fiberSidebandbusiness.industryLaserFrequency domain analysis; infrared devices; infrared lasersWavelengthFrequency domainMode coupling[ SPI.OPTI ] Engineering Sciences [physics]/Optics / PhotonicbusinessOptics (physics.optics)Physics - Optics
researchProduct

Label swapper device for spectral amplitude coded optical packet networks monolithically integrated on InP

2011

In this paper the design, fabrication and experimental characterization of an spectral amplitude coded (SAC) optical label swapper monolithically integrated on Indium Phosphide (InP) is presented. The device has a footprint of 4.8x1.5 mm 2 and is able to perform label swapping operations required in SAC at a speed of 155 Mbps. The device was manufactured in InP using a multiple purpose generic integration scheme. Compared to previous SAC label swapper demonstrations, using discrete component assembly, this label swapper chip operates two order of magnitudes faster. © 2011 Optical Society of America.

FabricationComputer sciencePacket networksPhosphinesIntegrationIndium phosphideIndiumSemiconductor laser theoryFootprint (electronics)chemistry.chemical_compoundDiscrete componentsSpectral amplitudeComputer Communication NetworksTEORIA DE LA SEÑAL Y COMUNICACIONESMonolithically integratedOptical labelsOptical amplifierSignal processingbusiness.industryExperimental characterizationInPOptical DevicesSignal Processing Computer-AssistedEquipment DesignChipIntegration schemeAtomic and Molecular Physics and OpticsOptical packet networksEquipment Failure Analysischemistryvisual_artElectronic componentvisual_art.visual_art_mediumIndium phosphideOptoelectronicsMonolithic integrated circuitsbusinessLabel swapping
researchProduct

Electrical characterization of deoxyribonucleic acid hybridization in metal-oxide-semiconductor-like structures

2012

In this work, metal-oxide-semiconductor (MOS)-like sensors in which deoxyribonucleic acid (DNA) strands are covalently immobilized either on Si oxide or on a gold surface were electrically characterized. Si oxide fabrication process allowed us to have a surface insensitive to the solution pH. A significant shift in the flat band voltage was measured after single strand DNA immobilization (+0.47 +/- 0.04 V) and after the complementary strand binding (+0.07 +/- 0.02 V). The results show that DNA sensing can be performed using a MOS structure which can be easily integrated in a more complex design, thus avoiding the problems related to the integration of micro-electrochemical cells.

FabricationMaterials scienceComplementary strandPhysics and Astronomy (miscellaneous)OxideNanotechnologyElectrical characterizationSettore ING-INF/01 - ElettronicaComplex designSIO2 SURFACESMetalSi oxidechemistry.chemical_compoundCAPACITORSComplementary DNASolution pHFlat-band voltageMicro-electrochemical cellFIELD-EFFECT DEVICESMolecular biophysicsMetal oxide semiconductorDNAGold surfaceMOS structureIMMOBILIZATIONChemical engineeringchemistryFabrication proceCovalent bondvisual_artvisual_art.visual_art_mediumSingle strand DNABiosensorDNADNA sensing
researchProduct

Configurable low-cost plotter device for fabrication of multi-color sub-cellular scale microarrays.

2014

We report on the construction and operation of a low-cost plotter for fabrication of microarrays for multiplexed single-cell analyses. The printing head consists of polymeric pyramidal pens mounted on a rotation stage installed on an aluminium frame. This construction enables printing of microarrays onto glass substrates mounted on a tilt stage, controlled by a Lab-View operated user interface. The plotter can be assembled by typical academic workshops from components of less than 15 000 Euro. The functionality of the instrument is demonstrated by printing DNA microarrays on the area of 0.5 squared centimeters using up to three different oligonucleotides. Typical feature sizes are 5 μm diam…

FabricationMaterials scienceScale (ratio)NanotechnologyMultiplexingBiomaterialsUser-Computer InterfacePlotterHumansGeneral Materials ScienceBiochipOligonucleotide Array Sequence AnalysisEGF ReceptorsEpidermal Growth FactorOligonucleotideDNA-directed protein immobilization EGF receptors device automation multiplexed patterns polymer pen lithographyGeneral ChemistryMicrofluidic Analytical TechniquesErbB ReceptorsTissue Array AnalysisCosts and Cost AnalysisMCF-7 CellsPrintingDNA microarraySingle-Cell AnalysisBiotechnologySmall (Weinheim an der Bergstrasse, Germany)
researchProduct