Search results for " device"
showing 10 items of 1082 documents
Layered Double Hydroxides in Bioinspired Nanotechnology
2020
Layered Double Hydroxides (LDHs) are a relevant class of inorganic lamellar nanomaterials that have attracted significant interest in life science-related applications, due to their highly controllable synthesis and high biocompatibility. Under a general point of view, this class of materials might have played an important role for the origin of life on planet Earth, given their ability to adsorb and concentrate life-relevant molecules in sea environments. It has been speculated that the organic–mineral interactions could have permitted to organize the adsorbed molecules, leading to an increase in their local concentration and finally to the emergence of life. Inspired by nature, material s…
Computer vision profilometer: equipment and evaluation of measurements
1991
Abstract This paper describes a new equipment that measures roughness values by a computer vision (CV) technique. Measurements carried out by a CV profilometer are also evaluated. A laser source (power 2 mW), a cylindrical lens and a charge coupled device (CCD) TV-camera with a suitable optical system form an image of the profile of the sample under inspection. This image is then transformed into a binary image by thresholding and the line that divides the bright zone from the dark zone is the sample profile. From this line the characteristic roughness values can be calculated. The roughness measurements are carried out both by the CV profilometer and a stylus profilometer on eight specimen…
Long-cavity all-fiber ring laser actively mode locked with an in-fiber bandpass acousto-optic modulator.
2013
We demonstrate low-frequency active mode locking of an erbium-doped all-fiber ring laser. As the mode locker, we used a new in-fiber bandpass acousto-optic modulator showing 74% modulation depth, 3.7 dB power insertion losses, 4.5 nm of optical bandwidth, and 20 dB of nonresonant light suppression. The laser generates 330 ps mode-locked pulses over a 10 ns pedestal, at a 1.538 MHz frequency, with 130 mW of pump power. Fil: Cuadrado Laborde, Christian Ariel. Universidad de Valencia; España. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico La Plata. Centro de Investigaciones Opticas (i); Argentina. Provincia de Buenos Aires. Gobernación. Comisión de In…
On the use of front-end cascode rectifiers based on normally on SiC JFET and Si MOSFET
2014
The new wide band-gap semiconductor devices provide new properties to be explored. Normally on silicon carbide (SiC) JFET power devices have several advantages, in particular low switching losses and the potential capabilities of high temperature and high reverse blocking voltage. Looking for improving the overall efficiency in power converters, new structures based on these power devices might be studied. In this paper, a cascode rectifier based on normally on SiC JFET is presented and analyzed. This rectification structure can be applied as front-end rectifier stage for ac-dc power converters, increasing the overall efficiency of these topologies. A second cascode rectifier based on silic…
A Comparative Performance Study of a 1200 V Si and SiC MOSFET Intrinsic Diode on an Induction Heating Inverter
2014
This paper presents a comparison of the behavior of the intrinsic diode of silicon (Si) and silicon carbide (SiC) MOSFETs. The study was done for 1200 V Si and SiC MOSFETs. The data sheet from manufacturers shows the characteristics of MOSFET' intrinsic diode when gate source voltage (VGS) is 0 V. There are applications where the MOSFET' intrinsic diode is used while VGS is different than 0 V. One of these applications is induction heating, where depending on the load and the regulation system, the diode can conduct a significant part of the inverter current. In most applications which use the MOSFET' intrinsic diode, the turn ON of the intrinsic diode happens at VGS = 0 V. After a blanking…
Spatiotemporal colorimetry to reveal electrochemical kinetics of poly(o-toluidine) films along ITO surface
2018
Abstract Sheet resistance of transparent conducting electrodes can affect dramatically the electrochromic response of surface confined active species in any electrochromic device. The generated gradient of effective potential on the electrode surface has a direct impact on the electrochemical kinetics of these species. In this work, the electrochromic poly (o-toluidine) (POT) film, a derivative polyaniline, was deposited along a narrow, long transparent indium tin oxide (ITO) supporting electrode with a sheet resistivity of 30 Ω cm−1. This configuration was used as a model to simulate a surface electrical conduction from the external metallic contact to the opposite extreme of ITO with an i…
Correlating the Lifetime and Fluorine Content of Iridium(III) Emitters in Green Light-Emitting Electrochemical Cells
2013
In light-emitting electrochemical cells, the lifetime of the device is intrinsically linked to the stability of the phosphorescent emitter. In this study, we present a series of ionic iridium(III) emitters based on cyclometalating phenylpyridine ligands whose fluorine substituents are varied in terms of position and number. Importantly, despite these structural modifications, the emitters exhibit virtually identical electrochemical and spectroscopic properties, which allows for proper comparison in functional devices. Quantum chemical calculations support the properties measured in solution and suggest great similarities regarding the electronic structures of the emitters. In electrolumines…
Infrared microspectroscopy of biochemical response of living cells in microfabricated devices
2010
Abstract First experiments demonstrating the suitability of novel microfabricated fluidic devices for measuring living cells in physiological environment by synchrotron radiation (SR) Fourier Transform Infrared microspectroscopy (μ-FTIR) are presented. The devices were fabricated on CaF 2 windows, using the photoresist XARP 3100/10 to define the liquid cell lay-out. Therefore, the sample holder is transparent to both visible and infrared light, robust, completely recyclable and with a precise spacing. Using prototype devices of thicknesses 9, 5 and 3 μm, we studied the response of the U937 monocytic cell line to mechanical compression. The temporal evolution of the FTIR spectra, characteris…
Diode laser reliability in dynamic laser speckle application: Stability and signal to noise ratio
2018
Abstract The biospeckle, or dynamic laser speckle, is used as a potential tool to monitor activity in many biological and non-biological materials from agriculture to medicine, and it is usually based on the use of He-Ne and diode lasers, the latter of which has great potential to be embedded in portable equipment. Some queries about the stability of the diode laser were raised, such as the real influence of the mode hopping phenomenon as a drawback in solid-state devices in comparison to the well-known He-Ne lasers, and thus we decided to test it . In addition, we present an alternative way to enhance the stability and the signal-to-noise ratio of the information using a relative index rat…
Comparison of impact characteristics of four different ice hockey arena dasher boards
2012
During recent years the incidence of ice hockey related concussions has increased. Therefore, the main aim of this study was to determine how dasher board materials and structures affect impact characteristics and thereby concussion risk. The measurements were divided into two parts; 1. physiological characteristics of body checks were determined in real game measurements, and 2. simulation of body checks in the laboratory. Peak forces and stopping distances were determined from the high-speed camera data, and stiffness values were subsequently calculated. Dasher board materials and structures had a clear effect on impact characteristics. Flexible protective shielding material resulted in 1…