Search results for " device"
showing 10 items of 1082 documents
Facepiece filtering respirators with exhalation valve should not be used in the community to limit SARS-CoV-2 diffusion.
2020
Building a benchmark through active surveillance of intensive care unit-acquired infections: the Italian network SPIN-UTI.
2010
The Italian Nosocomial Infections Surveillance in Intensive Care Units (ICUs) (SPIN-UTI) project of the Italian Study Group of Hospital Hygiene (GISIO - SItI) was undertaken to ensure standardisation of definitions, data collection and reporting procedures using the Hospital in Europe Link for Infection Control through Surveillance (HELICS)-ICU benchmark. Before starting surveillance, participant ICUs met in order to involve the key stakeholders in the project through participation in planning. Four electronic data forms for web-based data collection were designed. The six-month patient-based prospective survey was undertaken from November 2006 to May 2007, preceded by a one-month surveilla…
Sensor-Oriented Passive RFID
2010
This chapter addresses the design of new UHF tag antennas for sensing applications able to host detectors and additional electronics but also to act as passive sensor itself for some modification of the target. Starting from the consideration that the tag is both a digital and an analog device, sensing data may be achieved without using microcontrollers by a simple signal processing of the tag response and of the turn-on power. The chapter is particularly focused on the monitoring of human body features even if the proposed ideas and devices, here demonstrated by simulations and experimentation, may also be applied in a variety of scenarios.
Pathways of Innovation: The I-District Effect Revisited
2018
The I-district effect establishes the existence of dynamic efficiency in Marshallian industrial districts in the form of a positive innovative differential comparing to the average of the economy. The hypothesis has been empirically validated for the case of technological innovation using patent indicators. Empirical research has assumed that all types of patentable figures (utility models, national patents, EPO, WIPO) have the same weight regardless of its actual or expected market value, which may be questionable given the differences in coverage, protection and cost of each figure. In this article, we question the existence of the I-district effect when each patent is weighted by its exp…
Characterization of MEMS accelerometer self-noise by means of PSD and Allan Variance analysis
2017
In this paper, we have studied the sources of error of a low-cost 3-axis MEMS accelerometer by means of Power Spectral Density and Allan Variance techniques. These techniques were applied to the signals acquired from ten identical devices to characterize the variability of the sensor produced by the same manufacturer. Our analysis showed as identically produced accelerometer have somehow variable behavior in particular at low frequency. It is therefore of paramount importance before their use in Inertial Navigation or Earthquakes Monitoring System, a complete characterization of each single sensors.
Compositional and Optical Gradient in Films of PbZrxTi1-xO3 (PZT) Family
2011
Pb(ZrxTi1-x)O3 (PZT) (x = 0-1) films have attracted the attention of researchers for the past 30 years due to their excellent ferroelectric (FE) and electromechanical properties, which have led to the commercialization of thin PZT films for ferroelectric random access memory (FeRAM), forming a market of several millions USD annually. Ferroelectricity of perovskite oxide thin films, especially PZT thin films, can be exploited in semiconductor devices to achieve non-volatile random access memory (NVRAM) with high-speed access and long endurance, which can overcome the barriers, encountered in current semiconductor memory technologies. The ferroelectricity can be also exploited to voltage depe…
An integrated Tissue Engineering approach to Human Bronchial model: Biodegradable Scaffold and Microfluidics Platform
L’ingegneria tissutale è la combinazione di cellule, materiali e metodi di ingegneria, insieme con opportuni fattori biochimici e fisico-chimici, volta a migliorare o sostituire le funzioni biologiche di tessuti danneggiati [1, 2]. A tal proposito supporti porosi e sistemi microfluidici sono utilizzati per scopi di ingegneria tissutale. Scaffold polimerici biodegradabili sono stati sfruttati come supporti strutturali per rigenerare vari tessuti quali ossa, cartilagini, nervi, legamenti, pelle e fegato. Una geometria porosa aperta con canali interconnessi è un prerequisito per la crescita cellulare ad alta densità e per un trasporto di nutrienti, ossigeno e prodotti di scarto metabolici. …
A voice-activated key for the Apple Macintosh computer
1989
An interface circuit to connect a microphone to an Apple Macintosh computer is described. The Apple Macintosh mouse port is used as the input port, and the microphone activation simulates a mouse press.
Minimum displacement design of base isolation devices
2014
Bioinspired Metal-Organic Frameworks in Mixed Matrix Membranes for Efficient Static/Dynamic Removal of Mercury from Water
2020
The mercury removal efficiency of a novel metal-organic framework (MOF) derived from the amino acid S-methyl-L-cysteine is presented and the process is characterized by single-crystal X-ray crystallography. A feasibility study is further presented on the performance of this MOF and also that of another MOF derived from the amino acid L-methionine when used as the sorbent in mixed matrix membranes (MMMs). These MOF-based MMMs exhibit high efficiency and selectivity in both static and dynamic regimes in the removal of Hg2+ from aqueous environments, due to the high density of thioalkyl groups decorating MOF channels. Both MMMs are capable to reduce different concentration of the pollutant to …