Search results for " device"

showing 10 items of 1082 documents

Facepiece filtering respirators with exhalation valve should not be used in the community to limit SARS-CoV-2 diffusion.

2020

Microbiology (medical)Aerosols2019-20 coronavirus outbreakbusiness.product_categoryCoronavirus disease 2019 (COVID-19)business.industryEpidemiologySevere acute respiratory syndrome coronavirus 2 (SARS-CoV-2)AcousticsExhalationCOVID-19Infectious DiseasesResidence CharacteristicsCOVID-19 SARS-CoV-2 FFR medical mask Facepice filtering respiratorsMedicineHumansEquipment FailureRespiratorRespiratory Protective DevicesbusinessLetter to the EditorInfection control and hospital epidemiology
researchProduct

Building a benchmark through active surveillance of intensive care unit-acquired infections: the Italian network SPIN-UTI.

2010

The Italian Nosocomial Infections Surveillance in Intensive Care Units (ICUs) (SPIN-UTI) project of the Italian Study Group of Hospital Hygiene (GISIO - SItI) was undertaken to ensure standardisation of definitions, data collection and reporting procedures using the Hospital in Europe Link for Infection Control through Surveillance (HELICS)-ICU benchmark. Before starting surveillance, participant ICUs met in order to involve the key stakeholders in the project through participation in planning. Four electronic data forms for web-based data collection were designed. The six-month patient-based prospective survey was undertaken from November 2006 to May 2007, preceded by a one-month surveilla…

Microbiology (medical)Malemedicine.medical_specialtylaw.inventioninfection rates; device utilisation ratio; active surveillancelawIntensive careEpidemiologymedicineInfection controlHumansCumulative incidenceIntensive care medicineCross InfectionInfection ControlRisk Managementbusiness.industryIncidence (epidemiology)Data CollectionBacterial pneumoniaGeneral MedicineMiddle Agedmedicine.diseaseIntensive care unitIntensive Care UnitsInfectious DiseasesItalyEmergency medicineElectronic dataFemalebusinessSentinel SurveillanceThe Journal of hospital infection
researchProduct

Sensor-Oriented Passive RFID

2010

This chapter addresses the design of new UHF tag antennas for sensing applications able to host detectors and additional electronics but also to act as passive sensor itself for some modification of the target. Starting from the consideration that the tag is both a digital and an analog device, sensing data may be achieved without using microcontrollers by a simple signal processing of the tag response and of the turn-on power. The chapter is particularly focused on the monitoring of human body features even if the proposed ideas and devices, here demonstrated by simulations and experimentation, may also be applied in a variety of scenarios.

MicrocontrollerSignal processingUltra high frequencySIMPLE (military communications protocol)business.industryComputer scienceDetectorElectronicsRFID sensorbusinessHost (network)Computer hardwareAnalog device
researchProduct

Pathways of Innovation: The I-District Effect Revisited

2018

The I-district effect establishes the existence of dynamic efficiency in Marshallian industrial districts in the form of a positive innovative differential comparing to the average of the economy. The hypothesis has been empirically validated for the case of technological innovation using patent indicators. Empirical research has assumed that all types of patentable figures (utility models, national patents, EPO, WIPO) have the same weight regardless of its actual or expected market value, which may be questionable given the differences in coverage, protection and cost of each figure. In this article, we question the existence of the I-district effect when each patent is weighted by its exp…

MicroeconomicsEmpirical researchValue (economics)EconomicsProduction (economics)Dynamic efficiencyDifferential (mechanical device)Market valueIndustrial districtWeighting
researchProduct

Characterization of MEMS accelerometer self-noise by means of PSD and Allan Variance analysis

2017

In this paper, we have studied the sources of error of a low-cost 3-axis MEMS accelerometer by means of Power Spectral Density and Allan Variance techniques. These techniques were applied to the signals acquired from ten identical devices to characterize the variability of the sensor produced by the same manufacturer. Our analysis showed as identically produced accelerometer have somehow variable behavior in particular at low frequency. It is therefore of paramount importance before their use in Inertial Navigation or Earthquakes Monitoring System, a complete characterization of each single sensors.

Microelectromechanical systemsEngineering010504 meteorology & atmospheric sciencesbusiness.industrySpectral densityLow frequency010502 geochemistry & geophysicsAccelerometer01 natural sciencesCharacterization (materials science)AccelerationSettore ING-INF/04 - AutomaticaElectronic engineeringAllan varianceAccelerometers Micromechanical devices Standards Earthquakes Acceleration Monitoring Inertial navigationbusinessInertial navigation system0105 earth and related environmental sciences2017 7th IEEE International Workshop on Advances in Sensors and Interfaces (IWASI)
researchProduct

Compositional and Optical Gradient in Films of PbZrxTi1-xO3 (PZT) Family

2011

Pb(ZrxTi1-x)O3 (PZT) (x = 0-1) films have attracted the attention of researchers for the past 30 years due to their excellent ferroelectric (FE) and electromechanical properties, which have led to the commercialization of thin PZT films for ferroelectric random access memory (FeRAM), forming a market of several millions USD annually. Ferroelectricity of perovskite oxide thin films, especially PZT thin films, can be exploited in semiconductor devices to achieve non-volatile random access memory (NVRAM) with high-speed access and long endurance, which can overcome the barriers, encountered in current semiconductor memory technologies. The ferroelectricity can be also exploited to voltage depe…

Microelectromechanical systemsMaterials sciencebusiness.industryFerroelectric ceramicsFerroelectric RAMOptoelectronicsSemiconductor memorySemiconductor deviceThin filmbusinessFerroelectricityPyroelectricity
researchProduct

An integrated Tissue Engineering approach to Human Bronchial model: Biodegradable Scaffold and Microfluidics Platform

L’ingegneria tissutale è la combinazione di cellule, materiali e metodi di ingegneria, insieme con opportuni fattori biochimici e fisico-chimici, volta a migliorare o sostituire le funzioni biologiche di tessuti danneggiati [1, 2]. A tal proposito supporti porosi e sistemi microfluidici sono utilizzati per scopi di ingegneria tissutale. Scaffold polimerici biodegradabili sono stati sfruttati come supporti strutturali per rigenerare vari tessuti quali ossa, cartilagini, nervi, legamenti, pelle e fegato. Una geometria porosa aperta con canali interconnessi è un prerequisito per la crescita cellulare ad alta densità e per un trasporto di nutrienti, ossigeno e prodotti di scarto metabolici. …

Microfluidics deviceHuman bronchial mucosaSettore ING-IND/24 - Principi Di Ingegneria ChimicaTissue engineering; Biodegradable membranes; Microfluidics devices; Human bronchial mucosa;Tissue engineeringBiodegradable membrane
researchProduct

A voice-activated key for the Apple Macintosh computer

1989

An interface circuit to connect a microphone to an Apple Macintosh computer is described. The Apple Macintosh mouse port is used as the input port, and the microphone activation simulates a mouse press.

MicrophoneComputer scienceInterface (computing)Experimental and Cognitive PsychologyPort (circuit theory)Voice command deviceComputerSystemsOrganization_MISCELLANEOUSComputer graphics (images)Key (cryptography)Psychology (miscellaneous)Apple macintoshGeneralLiterature_REFERENCE(e.g.dictionariesencyclopediasglossaries)ComputingMilieux_MISCELLANEOUSGeneral PsychologyBehavior Research Methods, Instruments, & Computers
researchProduct

Minimum displacement design of base isolation devices

2014

Minimum displacement optimal design base isolation devicesSettore ICAR/08 - Scienza Delle Costruzioni
researchProduct

Bioinspired Metal-Organic Frameworks in Mixed Matrix Membranes for Efficient Static/Dynamic Removal of Mercury from Water

2020

The mercury removal efficiency of a novel metal-organic framework (MOF) derived from the amino acid S-methyl-L-cysteine is presented and the process is characterized by single-crystal X-ray crystallography. A feasibility study is further presented on the performance of this MOF and also that of another MOF derived from the amino acid L-methionine when used as the sorbent in mixed matrix membranes (MMMs). These MOF-based MMMs exhibit high efficiency and selectivity in both static and dynamic regimes in the removal of Hg2+ from aqueous environments, due to the high density of thioalkyl groups decorating MOF channels. Both MMMs are capable to reduce different concentration of the pollutant to …

Mixed matrixMaterials scienceGroundwater remediationchemistry.chemical_element02 engineering and technology010402 general chemistryAigua potable Depuració01 natural sciencesBiomaterialscapture devicemercury(II)ElectrochemistryMaterialsmetal-organic frameworksfungiwater remediation021001 nanoscience & nanotechnologyCondensed Matter Physics6. Clean water0104 chemical sciencesElectronic Optical and Magnetic MaterialsMercury (element)MembranechemistryChemical engineeringMetal-organic frameworkmixed matrix membranes0210 nano-technology
researchProduct