Search results for " enhancement."

showing 10 items of 513 documents

Acute Effects of Loaded Half-Squat Jumps on Sprint Running Speed in Track and Field Athletes and Soccer Players

2016

The purpose of the study was to determine the acute responses to a jump squat protocol designed to induce postactivation potentiation on sprint running performance in experienced track and field athletes and soccer players. Twenty-five regional level athletes (12 track and field: ∼17 years; ∼177 cm; ∼73 kg and 13 soccer: ∼18 years; ∼175 cm; ∼72 kg) performed 2 test sessions assessing 40-m sprint running performance in a balanced, crossover design. Dual-beam light timing gates measured 0-20 and 20-40 m sprint times before and after either 9 minutes of sitting (control) or 2 sets of 6 repetition half-squat jump with the load eliciting maximum power (experimental) conditions. Sprint performanc…

MaleAcute effectsmedicine.medical_specialtyAdolescentPhysical Therapy Sports Therapy and RehabilitationSquatcomplex trainingAthletic Performance030204 cardiovascular system & hematologySittingRunningpower03 medical and health sciences0302 clinical medicineSoccermedicineHumansOrthopedics and Sports MedicineMuscle StrengthTrack and field athleticsta315MathematicsbiologyAthletesTrack and Field030229 sport sciencesGeneral Medicinebiology.organism_classificationperformance enhancementPAPSprintAthletesPhysical therapyPost activation potentiationJumpcontrast trainingJournal of Strength and Conditioning Research
researchProduct

Prevalence and prognostic impact of nonischemic late gadolinium enhancement in stress cardiac magnetic resonance

2020

Aim To assess the prevalence and prognostic significance of NI-LGE in patients undergoing stress-CMR. Methods Stress-CMR with either dipyridamole or adenosine was performed in 283 patients (228 men, 81%) including perfusion imaging, wall motion evaluation and LGE. Follow-up was completed in all enrolled patients (median time: 1850 days; interquartile range: 1225-2705 days). Composite endpoint included cardiac death, ventricular tachycardia, myocardial infarction, stroke, hospitalization for cardiac cause and coronary revascularization performed beyond 90 days from stress-CMR scans. Results One hundred and twelve patients (40%) had negative LGE (no-LGE), 140 patients (49%) I-LGE and 31 patie…

MaleAdenosineTime FactorsVasodilator AgentsContrast MediaPerfusion scanning030204 cardiovascular system & hematologyVentricular tachycardia0302 clinical medicineRisk FactorsInterquartile rangePrevalence030212 general & internal medicineMyocardial infarctionStrokenonischemic fibrosislate gadolinium enhancement; nonischemic cardiac findings; nonischemic fibrosis; prognosis; stress perfusion cardiac magnetic resonanceDipyridamoleGeneral MedicineMiddle AgedMagnetic Resonance ImagingDipyridamolelate gadolinium enhancementstress perfusion cardiac magnetic resonanceembryonic structurescardiovascular systemCardiologyFemaleCardiology and Cardiovascular MedicinePerfusionmedicine.drugnonischemic cardiac findingsmedicine.medical_specialtyHeart DiseasesPerfusion ImagingRisk Assessment03 medical and health sciencesPredictive Value of TestsInternal medicinemedicineHumanscardiovascular diseasesSurvival analysisAgedRetrospective Studiesbusiness.industryMyocardiummedicine.diseaseFibrosisLate gadolinium enhancement Nonischemic cardiac findings Nonischemic fibrosis Prognosis Stress perfusion cardiac magnetic resonanceprognosisbusinessJournal of Cardiovascular Medicine
researchProduct

Complete tumor prevention by engineered tumor cell vaccines employing nonviral vectors.

2004

We report that 100% mice survival after tumor challenge is achieved with cytokine-engineered cells employing nonviral lipoplexes and without using viral vectors. We describe this effect with cytokine-secreting tumor cell vaccines, based on cell clones or fresh transfected cells. Tumor cells were transfected with murine granulocyte-macrophage colony-stimulating factor (GM-CSF) or IL-4 plasmids employing the cationic lipid DOTAP, were irradiated (150 Gy) and kept frozen until use. The transfection efficacy was analyzed by qRT-PCR and flow cytometry. Vaccination induced potent antitumor rejection, resulting in 100% mice survival. Furthermore, the antitumor immunity was long lasting, since a tw…

MaleCancer ResearchSkin NeoplasmsGenetic enhancementCellGenetic VectorsAntineoplastic AgentsBiologyCancer VaccinesViral vectorFlow cytometryMicemedicineAnimalsMolecular BiologyMelanomaInterleukin 4medicine.diagnostic_testReverse Transcriptase Polymerase Chain ReactionMelanomaGranulocyte-Macrophage Colony-Stimulating FactorTransfectionGenetic TherapyNeoplasms Experimentalmedicine.diseaseFlow CytometryVirologySurvival AnalysisMice Inbred C57BLmedicine.anatomical_structureGranulocyte macrophage colony-stimulating factorMolecular MedicineFemaleInterleukin-4Genetic Engineeringmedicine.drugCancer gene therapy
researchProduct

Prevalence of coronary artery intramyocardial course in a large population of clinical patients detected by multislice computed tomography coronary a…

2008

Background: Intramyocardial course, an inborn coronary anomaly, is defined as a segment of a major epicardial coronary artery that runs intramurally through the myocardium; in particular, we distinguish myocardial bridging, in which the vessel returns to an epicardial position after the muscle bridge, and intramyocardial course, which is described as a vessel running and ending in the myocardium. Purpose: To evaluate the prevalence of myocardial bridging and intramyocardial course of coronary arteries as defined by multidetector computed tomography (MDCT) angiography. Material and Methods: The study population consisted of 242 consecutive patients (211 men, 31 women; mean age 59±6 years) w…

MaleChest Painmedicine.medical_specialtyCoronary Vessel AnomaliesContrast MediaCoronary AngiographyChest painCoronary artery diseaseElectrocardiographyImaging Three-DimensionalInternal medicineHeart ratePrevalencemedicineHumansRadiology Nuclear Medicine and imagingMultisliceObserver VariationRadiological and Ultrasound Technologymedicine.diagnostic_testbusiness.industryGeneral MedicineMiddle AgedAtenololmedicine.diseaseIopamidolRadiographic Image EnhancementCoronary arteriesmedicine.anatomical_structurecoronary arteryCTCardiologyFemaleRadiologymedicine.symptomTomography X-Ray ComputedbusinessElectrocardiographymedicine.drugArtery
researchProduct

EEG-related Functional MRI in Benign Childhood Epilepsy with Centrotemporal Spikes

2003

The localization of epileptic foci is an important issue in children with extratemporal epilepsies. However, the value of noninvasive methods such as the EEG-assisted functional magnetic resonance imaging (fMRI) has not been sufficiently investigated in children. As a model of extratemporal epilepsies, we studied 7 patients aged 5 to 12 (median 10) years with benign childhood epilepsy and centrotemporal (rolandic) spikes. Interictal spikes were recorded during the fMRI acquisition on a MR-compatible battery-powered digital EEG system with 16 channels. The fMRI sequences were correlated off-line with the EEG spikes and analyzed with the software Statistical Parametrical Mapping SPM99. The fM…

MaleChildhood epilepsyElectroencephalographyEEG-fMRICentral nervous system diseaseEpilepsyOxygen ConsumptionImage Processing Computer-AssistedmedicineHumansIctalChildEvoked PotentialsMathematical ComputingBrain Mappingmedicine.diagnostic_testElectroencephalographySignal Processing Computer-AssistedImage Enhancementmedicine.diseaseEpilepsy RolandicMagnetic Resonance ImagingTemporal LobeFunctional imagingNeurologyChild PreschoolFemaleNeurology (clinical)Functional magnetic resonance imagingPsychologyNeuroscienceEpilepsia
researchProduct

A supervised learning framework of statistical shape and probability priors for automatic prostate segmentation in ultrasound images

2013

Prostate segmentation aids in prostate volume estimation, multi-modal image registration, and to create patient specific anatomical models for surgical planning and image guided biopsies. However, manual segmentation is time consuming and suffers from inter-and intra-observer variabilities. Low contrast images of trans rectal ultrasound and presence of imaging artifacts like speckle, micro-calcifications, and shadow regions hinder computer aided automatic or semi-automatic prostate segmentation. In this paper, we propose a prostate segmentation approach based on building multiple mean parametric models derived from principal component analysis of shape and posterior probabilities in a multi…

MaleComputer sciencePosterior probabilityScale-space segmentationImage registrationHealth InformaticsSensitivity and SpecificityPattern Recognition AutomatedArtificial IntelligenceImage Interpretation Computer-AssistedHumansRadiology Nuclear Medicine and imagingComputer visionSegmentationUltrasonographyRadiological and Ultrasound TechnologySegmentation-based object categorizationbusiness.industryProstateProstatic NeoplasmsReproducibility of ResultsPattern recognitionImage segmentationImage EnhancementComputer Graphics and Computer-Aided DesignSpectral clusteringActive appearance modelData Interpretation StatisticalComputer Vision and Pattern RecognitionArtificial intelligencebusinessAlgorithmsMedical Image Analysis
researchProduct

Evaluation of intraindividual contrast enhancement variability for determining the maximum achievable consistency in CT

2019

OBJECTIVE. The purpose of this study was to quantify temporal variability in vascular and parenchymal enhancement within the same patient and to determine technique-related factors contributing to this variability. MATERIALS AND METHODS. We identified 100 patients who underwent four CT scans within 12 months with identical acquisition and contrast injection parameters. Enhancement was recorded in the abdominal aorta, main portal vein, liver parenchyma, and subcutaneous fat. Patient demographic and body habitus data were recorded. Injection-related factors were recorded including delay time from contrast injection to image acquisition. All pairwise differences in enhancement within each pati…

MaleContrast enhancementTime Factors030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineConsistency (statistics)MedicineHumansRadiology Nuclear Medicine and imagingAorta AbdominalVariabilityAgedRetrospective StudiesObserver Variationbusiness.industryPortal VeinEnhancementContrast mediaGeneral MedicineMiddle AgedSubcutaneous Fat AbdominalRadiographic Image EnhancementLiver030220 oncology & carcinogenesisFemalebusinessNuclear medicineTomography X-Ray ComputedCT
researchProduct

Higher intracoronary attenuation improves diagnostic accuracy in MDCT coronary angiography

2006

OBJECTIVE: The purpose of this study was to investigate whether the amount of intracoronary attenuation influences the diagnostic accuracy of MDCT coronary angiography in the detection of clinically significant stenosis. MATERIALS AND METHODS: One hundred twenty patients in sinus rhythm with suspected coronary artery disease who underwent MDCT of the heart and conventional coronary angiography were retrospectively selected. The population was divided into two groups depending on median (326 H) coronary vascular enhancement (i.e., low attenuation and high attenuation). The diagnostic accuracy of MDCT for the detection of clinically significant coronary artery lesions (> or = 50% lumen reduct…

MaleCoronary angiographymedicine.medical_specialtycardiac imaging cardiovascular disease contrast media CT coronary arteriographyPopulationLumen (anatomy)Coronary AngiographySensitivity and SpecificityAngina PectorisCoronary artery diseasePredictive Value of TestsmedicineHumansRadiology Nuclear Medicine and imagingSinus rhythmeducationCardiac imagingeducation.field_of_studybusiness.industryAttenuationCoronary StenosisGeneral MedicineMiddle Agedmedicine.diseaseRadiographic Image Enhancementmedicine.anatomical_structureFemaleRadiologyTomography X-Ray ComputedbusinessArteryAmerican Journal of Roentgenology
researchProduct

Texture analysis of cardiac cine magnetic resonance imaging to detect nonviable segments in patients with chronic myocardial infarction.

2017

[EN] Purpose: To investigate the ability of texture analysis to differentiate between infarcted nonviable, viable, and remote segments on cardiac cine magnetic resonance imaging (MRI). Methods: This retrospective study included 50 patients suffering chronic myocardial infarction. The data were randomly split into training (30 patients) and testing (20 patients) sets. The left ventricular myocardium was segmented according to the 17-segment model in both cine and late gadolinium enhancement (LGE) MRI. Infarcted myocardium regions were identified on LGE in short-axis views. Nonviable segments were identified as those showing LGE 50%, and viable segments those showing 0 < LGE < 50% transmural …

MaleLocal binary patternsMyocardial InfarctionMagnetic Resonance Imaging Cine030204 cardiovascular system & hematology030218 nuclear medicine & medical imagingTECNOLOGIA ELECTRONICA03 medical and health sciencesMagnetic resonance imaging0302 clinical medicineDiagnosisMachine learningmedicineImage Processing Computer-AssistedLate gadolinium enhancementHumansIn patientcardiovascular diseasesAnalysis methodRetrospective StudiesChronic myocardial infarctionTissue SurvivalReceiver operating characteristicmedicine.diagnostic_testbusiness.industryMagnetic resonance imagingHeartGeneral MedicineMiddle AgedClassificationChronic Diseasecardiovascular systemLeft ventricular myocardiumFemaleNuclear medicinebusinessMedical physics
researchProduct

Evaluation of demineralized bone and bone transplantsin vitroandin vivowith cone beam computed tomography imaging

2010

The objective of this study was to determine the ability of two flat panel cone beam CT (CBCT) devices to identify demineralized bone and bone transplants in vivo and in vitro.Datasets from patients with autologous bone grafts (n = 9, KaVo 3DeXam (KaVo, Biberach, Germany); n = 38, Accuitomo 40 (Morita, Osaka, Japan)) were retrospectively evaluated. Demineralized and non-demineralized porcine cancellous bone blocks were examined with the two CBCT devices. A SawBone skull (Pacific Research Laboratories, Vashon, WA) was used as a positioning tool for the bone blocks. Descriptive evaluation and image quality assessment were conducted on the KaVo 3DeXam data (voxel size 0.3 mm) using the OsiriX …

MaleModels AnatomicCone beam computed tomographySwineDentistryBone and BonesBone remodelingIn vivoImage Processing Computer-AssistedAnimalsHumansMedicineRadiology Nuclear Medicine and imagingGeneral DentistryEdetic AcidCone beam ctAgedChelating AgentsRetrospective StudiesCryopreservationBone Demineralization TechniqueBone TransplantationAnatomy Cross-SectionalOrthognathic Surgical Proceduresbusiness.industryResearchGeneral MedicineCone-Beam Computed TomographyMiddle AgedRadiographic Image EnhancementSkullmedicine.anatomical_structureOtorhinolaryngologyBone Demineralization TechniqueFemaleBone RemodelingDemineralized bonebusinessNuclear medicineCancellous boneDentomaxillofacial Radiology
researchProduct