Search results for " enhancement."
showing 10 items of 513 documents
Long-term therapeutic levels of human alpha-1 antitrypsin in plasma after hydrodynamic injection of nonviral DNA
2003
The transfection efficacy of several vectors containing the full genomic hAAT gene with its natural promoter (pTG7101) and others containing the cDNA of hAAT gene driven by cytomegalovirus immediate-early promoter or the 0.5 kb upstream of hAAT gene sequence has been studied by hydrodynamic tail-vein injection (20 microg/mouse). pTG7101 (but not the other plasmids) results in therapeutic and stable concentration of hAAT in plasma. A dose-response study with this plasmid (0.3-320 microg/mouse) confirms that hAAT remains long-term stable in plasma, with therapeutic concentrations of hAAT (>0.9 mg/ml). The parameters of the dose-response curve were: R: 0.98, E(max) 3449.0+/- 279.7 microg/ml an…
Improved contrast for myeloma focal lesions with T2-weighted Dixon images compared to T1-weighted images
2019
International audience; Purpose: The purpose of this study was twofold. First, to compare the contrast between spinal multiple myeloma (MM) focal lesions and surrounding bone marrow obtained on T2-weighted Dixon fat-only MR images to that obtained on T1-weighted spin-echo images. Second, to search for correlation between bone marrow fat fraction assessed by T2-weighted Dixon sequence and International Myeloma Working Group myeloma defining events.Materials and methods: A total of 39 patients with 112 focal MM lesions were included. There were 25 men and 14 women with a mean age of 68.8±9.8 [SD] years (range: 49-88 years). Contrast between focal MM lesions and surrounding bone marrow was cal…
Radiation exposure in biliary procedures performed to manage anastomotic strictures in pediatric liver transplant recipients: comparison between radi…
2013
The aim of this study was to estimate radiation exposure in pediatric liver transplants recipients who underwent biliary interventional procedures and to compare radiation exposure levels between biliary interventional procedures performed using an image intensifier-based angiographic system (IIDS) and a flat panel detector-based interventional system (FPDS). We enrolled 34 consecutive pediatric liver transplant recipients with biliary strictures between January 2008 and March 2013 with a total of 170 image-guided procedures. The dose-area product (DAP) and fluoroscopy time was recorded for each procedure. The mean age was 61 months (range 4–192), and mean weight was 17 kg (range 4–41). The…
Endoscopic assessment and grading of Barrett's esophagus using magnification endoscopy and narrow-band imaging: accuracy and interobserver agreement …
2010
Background: Three different classification systems for the evaluation of Barrett's esophagus (BE) using magnification endoscopy (ME) and narrow-band imaging (NBI) have been proposed. Until now, no comparative and external evaluation of these systems in a clinical-like situation has been performed. Objective: To compare and validate these 3 classification systems. Design: Prospective validation study. Setting: Tertiary-care referral center. Nine endoscopists with different levels of expertise from Europe and Japan participated as assessors. Patients: Thirty-two patients with long-segment BE. Interventions: From a group of 209 standardized prospective recordings collected on BE by using …
The accuracy of flexible spectral imaging colour enhancement for the diagnosis of gastric intestinal metaplasia
2014
Background Targeting biopsies on the basis of visual recognition of mucosal changes in the stomach instead of the currently accepted random biopsy sampling may be attractive. Aim The aim of this study was to evaluate the accuracy of endoscopic findings using flexible spectral imaging colour enhancement (FICE) for intestinal metaplasia (IM) in the gastric mucosa. Methods A consecutive cohort of 126 individuals aged over 50 years (27% men) was subjected to upper endoscopy using FICE. Histological assessment (per patient and per biopsy) was considered the gold standard to accuracy estimates. Results Histological assessment revealed IM in 50% of the individuals [OLGIM (operative link on gastric…
Comparison of Two- and Three-Dimensional Unenhanced and Contrast-Enhanced Echocardiographies Versus Cineventriculography Versus Cardiac Magnetic Reso…
2013
Contrast enhancement has been shown to improve detection of regional wall motion abnormalities (RWMA) in 2-dimensional (2D) echocardiography. This study determined the use of contrast enhancement in the setting of 3-dimensional (3D) echocardiography for definition of left ventricular RWMA compared with 2D echocardiography, cineventriculography, and cardiac magnetic resonance (CMR). In 63 patients, unenhanced and contrast-enhanced (SonoVue; Bracco Imaging S.p.A., Milan, Italy) 2D and 3D echocardiographies, CMR, and cineventriculography were performed. Hypokinesia in ≥1 segment defined the presence of RWMA. Interreader agreement (IRA) between 2 blinded off-site readers on presence of RWMA was…
Comparison of two artificial tear formulations for dry eye through high‐resolution optical coherence tomography
2011
Purpose: The aim was to determine the efficacy of two artificial eye-drop formulations by analysing the lower tear film meniscus volume through a commercial high-resolution spectral-domain optical coherence tomographer. Methods: Twenty dry eye patients (12 men, eight women, aged 57.5 ± 8.4 years) with refractive errors from -2.50 to +0.75 D (mean -1.34 ± 1.02 D) and cylinders lower than 1.00 D were examined. Tear meniscus volume was measured before, immediately after and 10, 30 and 60 minutes after instillation using the Copernicus high-resolution spectral-domain optical coherence tomographer (Optopol Tech SA, Zawiercie, Poland). Volume was calculated from the local area obtained from tom…
Chromoendoscopy and narrow-band imaging compared with high-resolution magnification endoscopy in Barrett's esophagus.
2008
Background & Aims: The aim of this study was to compare magnified still images obtained with high-resolution white light endoscopy, indigo carmine chromoendoscopy, acetic acid chromoendoscopy, and narrow-band imaging to determine the best technique for use in Barrett's esophagus. Methods: We obtained magnified images from 22 areas with the 4 aforementioned techniques. Seven endoscopists with no specific expertise in Barretes esophagus or advanced imaging techniques and 5 international experts in this field evaluated these 22 areas for overall image quality, mucosal image quality, and vascular image quality. In addition, the regularity of mucosal and vascular patterns and the presence of abn…
Fatal venous air embolism: proof and volumetry by helical CT
1995
Influence of convolution filtering on coronary plaque attenuation values: observations in an ex vivo model of multislice computed tomography coronary…
2007
Attenuation variability ( measured in Hounsfield Units, HU) of human coronary plaques using multislice computed tomography (MSCT) was evaluated in an ex vivo model with increasing convolution kernels. MSCT was performed in seven ex vivo left coronary arteries sunk into oil followingthe instillation of saline (1/infinity) and a 1/50 solution of contrast material ( 400 mgI/ml iomeprol). Scan parameters were: slices/ collimation, 16/0.75 mm; rotation time, 375 ms. Four convolution kernels were used: b30f-smooth, b36f-medium smooth, b46f-medium and b60f-sharp. An experienced radiologist scored for the presence of plaques and measured the attenuation in lumen, calcified and noncalcified plaques …