Search results for " fractures"

showing 10 items of 284 documents

Osteodystrophy in chronic liver diseases

2013

Osteoporosis and osteomalacia are, to date, among the most common metabolic diseases in the world. Lately, an association between metabolic bone diseases and chronic liver disease has been increasingly reported, inducing many authors to create a new nosographic entity known as 'hepatic osteodystrophy.' The importance of such a condition is further increased by the morbidity of these two diseases, which greatly reduce the quality of life because of frequent fractures, especially vertebral and femoral neck ones. For this reason, early identification of high-risk patients should be routinely performed by measuring bone mass density. The explanation for the association between bone diseases and…

Pediatricsmedicine.medical_specialtyPathologySettore MED/09 - Medicina InternaOsteoporosisInterferon therapychronic liver diseasesChronic liver diseaseBone DensityRisk FactorsInternal MedicinemedicineHumansOsteodystrophyFrequent fracturesFemoral neckOsteomalaciaDiphosphonatesbusiness.industryLiver Diseasesmedicine.diseaseOsteodystrophyBone Diseases Metabolicmedicine.anatomical_structureChronic DiseaseOsteomalaciaQuality of LifeEmergency MedicineBone mass densityOsteoporosisOsteodystrophy; chronic liver diseasesbusinessInternal and Emergency Medicine
researchProduct

The effect of dentine pre-treatment using bioglass and/or polyacrylic acid on the interfacial characteristics of resin-modified glass ionomer cements.

2018

Objective To evaluate the effect of load-cycle aging and/or 6 months artificial saliva (AS) storage on bond durability and interfacial ultramorphology of resin-modified glass ionomer cement (RMGIC) applied to dentine air-abraded using Bioglass 45S5 (BAG) with/without polyacrylic acid (PAA) conditioning.Methods RMGIC (Ionolux, VOCO) was applied onto human dentine specimens prepared with silicon-carbide abrasive paper or air-abraded with BAG with or without the use of PAA conditioning. Half of bonded-teeth were submitted to load cycling (150,000 cycles) and half immersed in deionised water for 24 h. They were cut into matchsticks and submitted immediately to microtensile bond strength (μTBS) …

Pre treatmentAdultCeramicsMaterials scienceSurface PropertiesGlass ionomer cementAcrylic Resins02 engineering and technologylaw.invention03 medical and health scienceschemistry.chemical_compoundTooth FracturesYoung Adult0302 clinical medicinestomatognathic systemlawBioglass 45S5Tensile StrengthLoad cyclingMaterials TestingHumansDental Restoration FailureComposite materialGeneral DentistryDental LeakageBond strengthPolyacrylic acidDental BondingResin modified030206 dentistry021001 nanoscience & nanotechnologyMolarResin CementsAir Abrasion DentalchemistryGlass Ionomer CementsBioactive glassDentin-Bonding AgentsDentinGlass0210 nano-technologyJournal of dentistry
researchProduct

[Percutaneous vertebroplasty]

2003

RadiographyFractures SpontaneousBack PainBone CementsHumansMinimally Invasive Surgical ProceduresOsteoporosisPolymethyl MethacrylateSpinal FracturesPercutaneous vertebroplastyInjections Spinal
researchProduct

Impacts of tailored, rehabilitation nursing care on functional ability and quality of life in hospitalized elderly patients after rib fractures

2021

Objectives: We aimed to analyze the effects of a tailored rehabilitation nursing care program on functional ability and quality of life in patients with conservative treatment for rib fractures. Design: Randomized controlled trial. Setting: Inpatient rehabilitation hospital. Subjects: Rib fracture patients treated conservatively were randomized into two groups (experimental and control group). Interventions: Patients in control group received Treatment as Usual (TAU) and patients included in experimental group received TAU and an added tailored rehabilitation nursing care program (RNT). Main measures: At baseline, and end of hospitalization treatment, the functional ability was assessed wit…

Rehabilitation nursingmedicine.medical_specialtyRib Fracturesbusiness.industryRehabilitationPhysical Therapy Sports Therapy and RehabilitationRehabilitation NursingHospitalizationConservative treatment03 medical and health sciences0302 clinical medicineQuality of life (healthcare)030220 oncology & carcinogenesisActivities of Daily LivingQuality of LifePhysical therapyHumansMedicineIn patient030212 general & internal medicineFunctional abilitybusinessCare programAgedClinical Rehabilitation
researchProduct

Long-term results after operative treatment of femoral neck fractures with ceramic head prostheses.

2001

ABSTRACT From 1 985-1 990, a total of 277 elderly patients underwent hemiarthroplasty using a ceramic head prosthesis. Average patient age was 81.7 years. Of these, 77 patients were available for follow-up examination in 1993. A standardized score was calculated assessing activity, gait, and hip pain; the average score was 58 out of 78 possible points. Three patients had hip pain, and in 4 patients, radiographic examination revealed protrusio acetabuli. Two of 4 patients underwent revision surgery for replacement of the cup, leaving the stem in situ. Because of the small number of prosthetic-related complications, hemiarthroplasty using a ceramic head prosthesis is the recommended surgical …

Reoperationmedicine.medical_specialtyCeramicsProtrusio acetabulimedicine.medical_treatmentRadiographyArthroplasty Replacement HipPainProsthesis DesignProsthesisFemoral Neck FracturesTimeFemoral headActivities of Daily LivingmedicineHumansOrthopedics and Sports MedicineFemoral neckAgedPain MeasurementAged 80 and overbusiness.industryAcetabulummedicine.diseaseArthroplastySurgeryFemoral Neck FracturesRadiographymedicine.anatomical_structureOrthopedic surgerySurgeryHip ProsthesisbusinessFollow-Up StudiesOrthopedics
researchProduct

Ganzkörper-Spiral-CT zur Primärdiagnostik polytraumatisierter Patienten unter Notfallbedingungen

1997

PURPOSE The aim of this study was to evaluate the role of a fast whole body helical CT scanner for primary diagnosis in trauma patients. METHODS 27 severely injured patients (9 women, 18 men; mean age 43 years) were first examined with a helical CT scanner allowing for digital radiograms up to a length of 1024 mm and continuous helical scans of up to 70 seconds (slice thickness 3 to 10 mm, pitch factor up to 2). The primary CT diagnosis was verified either by x-ray after the CT examination or during the subsequent days, by abdominal ultrasound, by additional CT scans in the following days, and by clinical follow-up. RESULTS CT showed all clinically relevant injuries of the head, spine, ches…

Rib cagebusiness.industrymedicine.diseasePolytraumaHelical ctmedicine.anatomical_structureExtremity fracturesCt examinationmedicineAbdomenRadiology Nuclear Medicine and imagingNuclear medicinebusinessWhole bodyPelvisRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

The Evaluation of Four Electronic Apex Locators in Teeth with Simulated Horizontal Oblique Root Fractures

2008

The accuracy of four electronic apex locators (EALs) to locate the apical limit in teeth with simulated horizontal oblique root fractures was investigated. A horizontal oblique incomplete root fracture was simulated on 20 freshly extracted maxillary anterior teeth by means of a notch made on the vestibular root plane 8 mm from the anatomic apex. The EALs investigated were the ProPex (Dentsply Maillefer, Ballaigues, Switzerland), the NovApex (Forum Technologies, Rishon Le-Zion, Israel), the Root ZX (J. Morita Corp, Kyoto, Japan), and the Elements Apex Locator (SybronEndo, Orange CA). The electronic measurements were compared with the real "working length." The accuracy obtained was of 80% (n…

Root planebusiness.industryOblique caseDentistryEquipment DesignMaterials testingTooth ApexElectronics MedicalTooth FracturesTooth rootTooth ApexMaterials TestingHumansOdontometryTooth RootbusinessGeneral DentistryRoot Canal PreparationAnterior teethMathematicsJournal of Endodontics
researchProduct

Volar and dorsal mid-shaft forearm plating using DCP and LC-DCP: interference with the interosseous membrane and forearm-kinematics.

2010

Purpose To clarify if dorsal plate osteosynthesis of the forearm shaft is associated with impingement of the interosseous membrane (IOM) and if rotational kinematics of the forearm are influenced. Background Forearm fractures are treated by separate incisions. Osteosynthesis via one approach in proximal forearm fractures was associated with higher rates of synostosis. It has been claimed that this is due to IOM impingement. Materials and methods 16 forearms of fresh frozen cadavers were dissected until only radius, ulna and the IOM remained. To preserve physiological forearm rotation, the elbow joint, the distal radio-ulnar joint and the carpus remained intact. In group 1, LC-DC and DC plat…

RotationElbowBone ScrewsProsthesis DesignSupinationFracture Fixation InternalForearmCadaverFracture fixationBone platemedicineCadaverHumansPronationAgedOsteosynthesisbusiness.industryInterosseous membraneUlnaForearm InjuriesGeneral MedicineAnatomyUlna FracturesBiomechanical Phenomenabody regionsForearmmedicine.anatomical_structureSurgerybusinessRadius FracturesBone PlatesActa chirurgica Belgica
researchProduct

Navigated percutaneous screw fixation of the pelvis with O-arm 2: two years' experience.

2020

Aim To evaluate the case series of the patients operated with percutaneous fixation by the navigation system based on 3D fluo-roscopic images, to assess the precision of a surgical implant and functional outcome of patients. Methods A retrospective study of pelvic ring fractures in a 2-year period included those treated with the use of the O-Arm 2 in com-bination with the Stealth Station 8. Pelvic fractures were classifi-ed according to the Tile and the Young-Burgess classification. All patients were examined before surgery, with X-rays and CT scans, and three days after surgery with additional CT scan. The positioning of the screws was evaluated according to the Smith score, the outcome wi…

Sacrum3D-fluoroscopic navigationBone ScrewsPelvisIliosacral fixationFracture Fixation InternalImaging Three-DimensionalSurgery Computer-AssistedO-arm Stealth Station S8Fragility fracture of pelvisHumansPelvic ring fracturesTomography X-Ray ComputedRetrospective StudiesMedicinski glasnik : official publication of the Medical Association of Zenica-Doboj Canton, Bosnia and Herzegovina
researchProduct

Bisphosphonate-associated femoral fracture: implication for management

2008

Studies carried out on individuals being treated long term with bisphosphonates have provoked considerable interest and perplexity about the effect that these drugs have on bone turnover in the long run. In fact the experiences reported by numerous researchers tend to highlight how treatment with high doses of bisphosphonates over many years, of individuals with osteoporosis complicated by or secondary to neoplastic pathologies, causes a suppression of bone turnover that over time predisposes the bone to the accumulation of micro damage that can then result in complicated fractures, as in the case described here.

Settore MED/18 - Chirurgia Generalefemoral fractures biphonates bone turnover
researchProduct