Search results for " imaging."
showing 10 items of 6165 documents
Cough is dangerous : neural correlates of implicit body symptoms associations
2016
The negative interpretation of body sensations (e.g., as sign of a severe illness) is a crucial cognitive process in pathological health anxiety (HA). However, little is known about the nature and the degree of automaticity of this interpretation bias. We applied an implicit association test (IAT) in 20 subjects during functional magnetic resonance imaging (fMRI) to investigate behavioral and neural correlates of implicit attitudes towards symptom words. On the behavioral level, body symptom words elicited strong negative implicit association effects, as indexed by slowed reaction times when symptom words were paired with the attribute harmless (incongruent condition) relative to a control …
Trans -Cyclooctene-Functionalized PeptoBrushes with Improved Reaction Kinetics of the Tetrazine Ligation for Pretargeted Nuclear Imaging
2020
Tumor targeting using agents with slow pharmacokinetics represents a major challenge in nuclear imaging and targeted radionuclide therapy as they most often result in low imaging contrast and high radiation dose to healthy tissue. To address this challenge, we developed a polymer-based targeting agent that can be used for pretargeted imaging and thus separates tumor accumulation from the imaging step in time. The developed targeting agent is based on polypeptide-graft-polypeptoid polymers (PeptoBrushes) functionalized with trans-cyclooctene (TCO). The complementary In-111-labeled imaging agent is a 1,2,4,5-tetrazine derivative, which can react with aforementioned TCO-modified PeptoBrushes i…
Molecular Mechanisms of the Blockage of Glioblastoma Motility
2021
Glioblastoma (GBM) is the most common and lethal brain tumor. GBM has a remarkable degree of motility and is able to infiltrate the healthy brain. In order to perform a rationale-based drug-repositioning study, we have used known inhibitors of two small Rho GTPases, Rac1 and Cdc42, which are upregulated in GBM and are involved in the signaling processes underlying the orchestration of the cytoskeleton and cellular motility. The selected inhibitors (R-ketorolac and ML141 for Cdc42 and R-ketorolac and EHT 1864 for Rac1) have been successfully employed to reduce the infiltration propensity of GBM in live cell imaging studies. Complementarily, all-atom simulations have elucidated the molecular …
High Bias Voltage CZT Detectors for High-flux Measurements
2017
In this work, we present the performance of new travelling heater method (THM) grown CZT detectors, recently developed at IMEM-CNR Parma, Italy. Thick planar detectors (3 mm thick) with gold electroless contacts on CZT crystals grown by Redlen Technologies (Victoria BC, Canada) were realized, with a planar cathode covering the detector surface (4.1 x 4.1 mm(2)) and a central anode (2 x 2 mm(2)) surrounded by a guard ring electrode. The detectors, characterized by low leakage currents at room temperature (4.7 nA/cm(2) at 1000 V/cm), allow good room temperature operation even at high bias voltages (> 7000 V/cm). At low rates, the detectors exhibit an energy resolution around 4 % FWIEM at 59.5…
Microscale X-ray mapping of CZT arrays: Spatial dependence of amplitude, shape and multiplicity of detector pulses
2018
In this work, we present the results of a microscale X-ray mapping of a 2 mm thick CZT pixel detector, with pixel pitches of 500 μm and 250 μm, using collimated synchrotron X-ray sources at the Diamond Light source (U. K.). The detector is dc coupled to a fast and low noise ASIC (PIXIE ASIC), characterized only by the preamplifier stage. A custom 16-channel digital readout electronics was used, able to perform online fast pulse shape and height analysis (PSHA), with low dead time and reasonable energy resolution at both low and high fluxes. The detector allows high bias voltage operation (> 5000 V/cm) and good energy resolution at room temperature (5.3 %, 2.3 % and 2.1 % FWHM at 22.1, 59…
Radiolabeling of Nanoparticles and Polymers for PET Imaging
2014
Nanomedicine has become an emerging field in imaging and therapy of malignancies. Nanodimensional drug delivery systems have already been used in the clinic, as carriers for sensitive chemotherapeutics or highly toxic substances. In addition, those nanodimensional structures are further able to carry and deliver radionuclides. In the development process, non-invasive imaging by means of positron emission tomography (PET) represents an ideal tool for investigations of pharmacological profiles and to find the optimal nanodimensional architecture of the aimed-at drug delivery system. Furthermore, in a personalized therapy approach, molecular imaging modalities are essential for patient screeni…
Value of Combined PET Imaging with [18F]FDG and [68Ga]Ga-PSMA-11 in mCRPC Patients with Worsening Disease during [177Lu]Lu-PSMA-617 RLT
2021
Despite the promising results of prostate-specific membrane antigen (PSMA)-targeted radioligand therapy (RLT) in metastatic castration-resistant prostate cancer (mCRPC), some patients show worsening disease during PSMA-RLT. We investigated the value of combined [18F]FDG and [68Ga]Ga-PSMA-11 PET imaging in this setting. In n = 29 mCRPC patients with worsening disease after a median of four cycles of [177Lu]Lu-PSMA-617 RLT, combined [18F]FDG and [68Ga]Ga-PSMA-11 PET imaging was performed to detect [18F]FDG-avid lesions with low or no PSMA expression (mismatch lesions). To evaluate prognostic implication of mismatch, survival analyses regarding presence, location, and [18F]FDG PET-derived para…
Prevalencia y factores de desgaste profesional en radiólogos durante la pandemia COVID-19
2022
Antecedentes: La epidemia por coronavirus 2019 (COVID-19) se ha extendido por todo el mundo desde principios de 2020, sometiendo a los profesionales sanitarios a una sobrecarga laboral ya un mayor nivel de estrés físico y emocional. Objetivos: El objetivo de este estudio es determinar la prevalencia de desgaste profesional y sus posibles factores asociados en los radiólogos españoles durante la COVID-19, y su comparación con la situación previa a la pandemia. Métodos: Estudio observacional realizado entre los meses de abril y agosto de 2020 (durante la pandemia) mediante una encuesta en línea. Se obtuvieron un total de 150 respuestas. Se recopiló y comparó la información demográfica y labor…
Hyperspectral Imaging of Macroinvertebrates : a Pilot Study for Detecting Metal Contamination in Aquatic Ecosystems
2018
The applicability of spectral analysis in detection of freshwater metal contamination was assessed by developing and testing a novel hyperspectral imaging (HSI) application for aquatic insect larvae (Trichoptera: Hydropsychidae). Larvae were first exposed to four different cadmium (Cd) concentrations: 0, 1, 10, and 100 μg L−1 for 96 h. Individual larvae were then preserved in ethanol, inspected with microscopy for the number of anomalies in larval gills, and imaged by hyperspectral camera operating with wavebands between 500 and 850 nm. Three additional larvae from each exposure were analyzed for tissue Cd concentration. Although the larval tissue Cd concentrations correlated positively wit…
Structured reporting of rectal cancer staging and restaging: A consensus proposal
2021
Background: Structured reporting (SR) in oncologic imaging is becoming necessary and has recently been recognized by major scientific societies. The aim of this study was to build MRI-based structured reports for rectal cancer (RC) staging and restaging in order to provide clinicians all critical tumor information. Materials and Methods: A panel of radiologist experts in abdominal imaging, called the members of the Italian Society of Medical and Interventional Radiology, was established. The modified Delphi process was used to build the SR and to assess the level of agreement in all sections. The Cronbach’s alpha (Cα) correlation coefficient was used to assess the internal consistency of ea…