Search results for " injection"
showing 10 items of 472 documents
LONG-ACTING AND SELECTIVE SUPPRESSION OF GROWTH HORMONE SECRETION BY SOMATOSTATIN ANALOGUE SMS 201-995 IN ACROMEGALY
1984
In 6 of 7 acromegalic patients a single subcutaneous injection of 50 micrograms of a new octapeptide somatostatin analogue (SMS 201-995) reduced serum growth hormone (GH) from 30 +/- 12 ng/ml to 1.4 +/- 0.4 (mean +/- SEM). Serum GH remained below basal concentration for 9 h. In the remaining patient who had very high basal preprandial serum GH, SMS 201-995 produced a reduction in serum GH of only 20%. Plasma glucose concentrations were increased to the upper limits of the normal range when a high-carbohydrate meal was consumed 2 h after injection. In non-diabetic patients plasma glucose did not exceed 129 mg/dl. The 40% decrease in plasma glucagon, which lasted for 7 h after SMS 201-995 inj…
Hormonal and molecular characterization of follicular fluid, cumulus cells and oocytes from pre-ovulatory follicles in stimulated and unstimulated cy…
2012
background: The use of ovarian stimulation, to stimulate a multi-follicular response for assisted reproduction treatments, may force the production of oocytes from follicles that do not reach optimal maturation, possibly yielding oocytes that are not fully competent. The present study aimed to define the follicular environment and oocyte competence of unstimulated pre-ovulatory follicles, to compare it with that of similar-sized stimulated follicles. For this purpose, we analyzed the follicular hormonal milieu, the oocyte meiotic spindle, the embryo development and the cumulus cells gene expression (GE) profiles. methods and results: The study population was divided in two groups: (i) 42 oo…
Antral follicle count (AFC) can be used in the prediction of ovarian response but cannot predict the oocyte/embryo quality or the in vitro fertilizat…
2007
To verify whether the antral follicle count (AFC) could predict ovarian response, oocyte/embryo quality, and IVF outcome.Prospective study.Instituto Universitario-Instituto Valenciano de Infertilidad, Valencia, Spain.One thousand seventy-four donors and 975 oocyte recipient cycles.Controlled ovarian hyperstimulation (COH), endometrial preparation, IVF/intracytoplasmic sperm injection, ET.COH and oocyte/embryo quality parameters and IVF outcome.We observed lower E(2) levels and fewer mature retrieved oocyte numbers among donors who showed an AFC that was10. These donors also showed significantly higher cancellation and no-donation rates; poor and/or insufficient response was the principal ca…
Laparoscopic Sentinel Lymph Node Detection After Hysteroscopic Injection of Technetium-99 in Patients With Endometrial Cancer
2015
Background and Objectives Endometrial cancer (EC) has an increasing incidence worldwide. Despite the unequivocal prognostic importance of nodal status, systematic lymphadenectomy is associated to elevated morbidity. Sentinel lymph node (SLN) biopsy is designed to avoid extensive nodal dissection and provide crucial oncologic information. The goal of this prospective study was to determine the feasibility, safety, and accuracy of laparoscopic SLN biopsy in EC obtained through hysteroscopic injection of technetium-99 (Tc-99). Methods From January 2008 to December 2012, a total of 42 women with EC were included in the study. We injected 20 mBq of Tc-99 hysteroscopically underneath the tumor mi…
A high oocyte yield for intracytoplasmic sperm injection treatment is associated with an increased chromosome error rate.
2009
Objective To compare the chromosome error rate among oocytes from stimulated ovaries after retrieval of 1–5 oocytes, 6–10 oocytes, and >10 oocytes. Design Retrospective cohort study. Setting A university-based human genetic institute in collaboration with a private fertility center. Patient(s) Nine hundred thirty-three women undergoing intracytoplasmic sperm injection (ICSI) with a poor prognosis. Intervention(s) Oocyte collection with ovarian stimulation. Polar body testing of ICSI oocytes for common chromosome errors. Main Outcome Measure(s) Chromosome error rate in oocytes, as determined by five-color fluorescence in situ hybridization. Result(s) In women less than 35 years and women bet…
Regulation of IgE production and airway reactivity by CD4(-)CD8(-) regulatory T cells
2015
The mechanisms of tolerance induction occurring in the course of allergen-specific immunotherapy have not been elucidated in full detail. Our study aimed to characterize high zone tolerance in mouse models of type I allergy and of allergic airway inflammation induced by subcutaneous sensitization of mice with high doses of the model allergen ovalbumin (OVA) without the use of adjuvant. Mice were immunized by subcutaneous injection of high doses (HD) of OVA or, for comparison, low doses (LD) of OVA in saline. HD-mice showed lower specific IgE, but augmented IgG in sera than LD-mice. Pre-treatment of mice with HD-OVA antigen-specifically inhibited IgE production subsequently induced by LD-OVA…
Determination of nitrite by inhibition of the chemiluminescence of acriflavine in a flow-injection assembly
2001
The indirect determination of nitrite was performed with a flow-injection assembly on the basis of the inhibition of the analytical output obtained in a luminometer by oxidation of acriflavine. The acriflavine solution merged with the nitrite and the resulting mixture was injected into a pure water stream. This solution merged with the oxidant solution (potassium permanganate in sulfuric acid medium) and the resulting chemiluminiscence was affected (inhibited) by the presence of nitrite after reaction with the aminoacridine. The method was applicable over the range 10–800 μg l−1 of nitrite with a correlation coefficient of 0.9960. The relative standard deviation was 1.4% and the throughput …
Spectrophotometric determination of promazine with an oxidative column in FIA manifolds
1992
Abstract A simple flow-injection spectrophotometric method for the determination of promazine is described. The two proposed procedures are based on the oxidation of analyte with a manganese dioxide column. Concentrations of promazine in the ranges 2–20 and 1–6 are determined with a relative standard deviation of 1.0%. The injection rates are 62 and 80 samples h −1 , respectively. The influence of foreign species and the determination of promazine in a pharmaceutical formulation are also reported.
Micellar liquid chromatography determination of rivaroxaban in plasma and urine. Validation and theoretical aspects.
2019
A Micellar Chromatographic method to determine rivaroxaban in plasma and urine has been developed. The samples were dissolved in the mobile phase (SDS 0.05 M – 1-propanol 12.5%, phosphate buffered at pH 7) and 20 μL directly injected, avoiding the extraction and purification steps. Using a C18 column and running under isocratic mode at 1 mL/min, analyte was eluted without interference from the matrix in <6.0 min. The detection absorbance wavelength was set to 250 nm. The procedure was validated by Food and Drug Administration guidelines in terms of: system suitability, calibration range (0.05–5 mg/L), linearity, sensitivity, robustness, carry-over effect, specificity, accuracy (−11.1 to 4.2…
Determination of the herbicide benfuresate by its photo-induced chemiluminescence using flow multicommutation methodology.
2007
The present paper deals with an analytical strategy based on coupling photo-induced chemiluminescence in a multicommutation continuous-flow methodology for the determination of the herbicide benfuresate. The solenoid valve inserted as small segments of the analyte solution was sequentially alternated with segments of the NaOH solution for adjusting the medium for the photodegradation. Both flow rates (sample and medium) were adjusted to required time for photodegradation, 90 s; and then, the resulting solution was also sequentially inserted as segments alternated with segments of the oxidizing solution system, hexacyanoferrate (III) in alkaline medium. The calibration range from 1 microg L(…