Search results for " ionization"
showing 10 items of 621 documents
Ammonium ion mediated resorcarene capsules: ESI-FTICRMS study on gas-phase structure and ammonium ion affinity of tetraethyl resorcarene and its per-…
2003
AbstractThe ammonium ion binding affinities of tetraethyl resorcarene (1) and its per-methylated derivative (2) were studied by electrospray ionization Fourier transform ion cyclotron resonance (ESI-FTICR) mass spectrometry. Ten different ammonium ions were tested as guests for the resorcarenes. A strong tendency for complex formation was observed with all ammonium ions of size and charge distribution suitable for noncovalent interactions with the cavities of the resorcarene hosts 1 and 2. Although differences in ammonium ion affinities were observed between 1 and 2 due to the dissimilar conformations, the overall tendency was that increase in the degree of substitution and the length of ca…
Extraction and Sample Preparation
2015
As everyone knows, the role played by extraction and sample preparation in the analytical sciences cannot be overemphasized. Despite tremendous advances in chromatography, detection, and other aspects of analysis, extraction and sample preparation remain a preanalysis ritual of critical importance. It has been estimated that around 50% to 70% possibly even more of the time and effort that goes into an analytical process comprises extraction and sample preparation. Sample preparation procedure can vary in the degree of selectivity, speed, and convenience, depending on the approach and conditions used, as well as on the geometric configurations of the extraction phase and conditions. Proper d…
Analysis of four parabens and bisphenols A, F, S in urine, using dilute and shoot and liquid chromatography coupled to mass spectrometry
2018
Abstract A new strategy for the analysis of 4 parabens (methylparaben, ethyl paraben, propyl paraben and butyl paraben) and 3 bisphenols (A, F and S) in human urine has been developed. Dilute and shoot and liquid chromatography coupled to mass spectrometry (LC-MS/MS) determination was employed. Procedural matched calibration, certified materials and spiked samples were used for validation. The obtained recoveries varied between 85 and 104% with a precision lower than 20% for all analytes. The LOQ was 0.20 ng mL for all analytes. Negative atmospheric pressure chemical ionization in the selected reaction monitoring mode was used for MS detection. The proposed method was successfully applied f…
Validation of a confirmatory method for the determination of macrolides in liver and kidney animal tissues in accordance with the European Union regu…
2006
Abstract This study proposes a simple multiresidue liquid chromatography–diode array detector (LC–DAD) method capable of determining seven macrolide antibiotics in samples of liver and kidney animals at concentrations lower than those allowed by current legislation. Samples were prepared by homogenizing the tissue with EDTA–McIlvaine's buffer and extracted with an Oasis HLB cartridge. The consumption of organic solvent during extraction was minimum. The analytes were detected by LC–DAD and also by liquid chromatography–mass spectrometry with electrospray ionization (LC–(ESI)MS). The method was specific, stable and robust enough for the required purposes. The DAD method was validated in acco…
Evaluation of analytical performance of gas chromatography coupled with atmospheric pressure chemical ionization Fourier transform ion cyclotron reso…
2019
Abstract A new analytical method was established and validated for the analysis of eighteen halogenated flame retardants (HFRs)in food products. Gas chromatography (GC) coupled to Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) employing atmospheric pressure chemical ionization (APCI) was used for the identification and quantitation of contaminants. Intra-laboratory validation of the method was performed with respect to recovery, repeatability, linear calibration ranges, instrumental and method limits of quantitation (i-LOQ and m-LOQ), and trueness was verified where possible by analysis of reference materials (RMs). The validation results indicated recoveries of ana…
Mycotoxin contamination in laboratory rat feeds and their implications in animal research
2016
Compound feed is particularly vulnerable to multi-mycotoxin contamination. A method for the determination of 12 mycotoxins; enniatins A, A1, B, B1; aflatoxins B1, B2, G1, G2; OTA; ZEA; T-2 and HT-2 by liquid chromatography-tandem mass spectrometry has been developed and applied for the analysis of laboratory rat commercial feeds. The method trueness was checked by recovery assays at three different spiked levels (n = 9). Recoveries ranged from 73% to 112%, and the intra-day and inter-day precision were lower than 9% and 13%, respectively. Limits of quantitation were lower than 15 μg/kg. Twenty-seven laboratory rats feed samples showed multi-contamination by at least three up to six differen…
A highly enantioselective abiotic receptor for malate dianion in aqueous solution
2006
The highly enantioselective molecular recognition of the malate dianion by a synthetic receptor in aqueous solution has been studied by potentiometric titrations, mass spectrometry (ESI-MS), diffusion measurements (PGSE NMR) and molecular modeling. Garcia-España Monsonis, Enrique, Enrique.Garcia-Es@uv.es
Solid state anion–π interactions involving polyhalides
2013
The stabilization of polyhalides in the solid state with the support of electron-deficient pentafluorophenyl groups is described. Furthermore, a synthetic approach towards the sensitive tetraiodide dianion is described and ESI mass spectrometric evidence for its presence in solution is reported.
Anion-Exchange Properties of Trifluoroacetate and Triflate Salts of N-Alkylammonium Resorcinarenes
2016
The synthesis of N-benzyl- and N-cyclohexylammonium resorcinarene trifluoroacetate (TFA) and triflate (OTf) salt receptors was investigated. Solid-state analysis by single-crystal X-ray diffraction revealed that the N-alkylammonium resorcinarene salts (NARSs) with different upper substituents had different cavity sizes and different affinities for anions. Anion-exchange experiments by mixing equimolar amounts of N-benzylammonium resorcinarene trifluoroacetate and N-cyclohexylammonium resorcinarene triflate, as well as N-benzylammonium resorcinarene triflate and N-cyclohexylammonium resorcinarene trifluoroacetate showed that the NARS with flexible benzyl groups preferred the larger OTf anion…
Determination of low-molecular-mass aliphatic carboxylic acids and inorganic anions from kraft black liquors by ion chromatography.
2007
An ion chromatographic (IC) method with suppressed conductivity detection (CD) was developed and validated for the quantitative determination of several low-molecular-mass aliphatic mono- and dicarboxylic acids as their carboxylate anions together with some inorganic anions (chloride, sulfate, and thiosulfate) from kraft black liquors. To confirm the identification of some carboxylate anions which lack commercial model substances, a qualitative IC method with suppressed electrospray ionization mass spectrometry (ESI-MS) was also developed. The separations were performed on an IonPac AS 11-HC anion-exchange column operated at 25 degrees C within 25 min by a gradient elution with aqueous pota…