Search results for " ionization"

showing 10 items of 621 documents

Ammonium ion mediated resorcarene capsules: ESI-FTICRMS study on gas-phase structure and ammonium ion affinity of tetraethyl resorcarene and its per-…

2003

AbstractThe ammonium ion binding affinities of tetraethyl resorcarene (1) and its per-methylated derivative (2) were studied by electrospray ionization Fourier transform ion cyclotron resonance (ESI-FTICR) mass spectrometry. Ten different ammonium ions were tested as guests for the resorcarenes. A strong tendency for complex formation was observed with all ammonium ions of size and charge distribution suitable for noncovalent interactions with the cavities of the resorcarene hosts 1 and 2. Although differences in ammonium ion affinities were observed between 1 and 2 due to the dissimilar conformations, the overall tendency was that increase in the degree of substitution and the length of ca…

Ammonium bromideChemistryStereochemistryElectrospray ionizationIon cyclotron resonance spectrometryMass spectrometryFourier transform ion cyclotron resonanceInclusion compoundchemistry.chemical_compoundStructural BiologyPolymer chemistryAmmoniumAmmonium ion bindingSpectroscopyJournal of the American Society for Mass Spectrometry
researchProduct

Extraction and Sample Preparation

2015

As everyone knows, the role played by extraction and sample preparation in the analytical sciences cannot be overemphasized. Despite tremendous advances in chromatography, detection, and other aspects of analysis, extraction and sample preparation remain a preanalysis ritual of critical importance. It has been estimated that around 50% to 70% possibly even more of the time and effort that goes into an analytical process comprises extraction and sample preparation. Sample preparation procedure can vary in the degree of selectivity, speed, and convenience, depending on the approach and conditions used, as well as on the geometric configurations of the extraction phase and conditions. Proper d…

AnalyteBioanalysisChromatographylcsh:QD71-142Article SubjectChemistryElectrospray ionizationlcsh:Analytical chemistryAtmospheric-pressure chemical ionizationQuechersMass spectrometryBioinformaticsAnalytical ChemistryEditorialSample preparationSolid phase extractionInternational Journal of Analytical Chemistry
researchProduct

Analysis of four parabens and bisphenols A, F, S in urine, using dilute and shoot and liquid chromatography coupled to mass spectrometry

2018

Abstract A new strategy for the analysis of 4 parabens (methylparaben, ethyl paraben, propyl paraben and butyl paraben) and 3 bisphenols (A, F and S) in human urine has been developed. Dilute and shoot and liquid chromatography coupled to mass spectrometry (LC-MS/MS) determination was employed. Procedural matched calibration, certified materials and spiked samples were used for validation. The obtained recoveries varied between 85 and 104% with a precision lower than 20% for all analytes. The LOQ was 0.20 ng mL for all analytes. Negative atmospheric pressure chemical ionization in the selected reaction monitoring mode was used for MS detection. The proposed method was successfully applied f…

AnalyteBisphenol AParabensAtmospheric-pressure chemical ionization02 engineering and technologyUrineMass spectrometry01 natural sciencesAnalytical Chemistrychemistry.chemical_compoundPhenolsTandem Mass SpectrometryHumansSulfonesBenzhydryl CompoundsChromatographyMethylparaben010401 analytical chemistrySelected reaction monitoring021001 nanoscience & nanotechnology0104 chemical sciencesParabenchemistrySpain0210 nano-technologyChromatography LiquidTalanta
researchProduct

Validation of a confirmatory method for the determination of macrolides in liver and kidney animal tissues in accordance with the European Union regu…

2006

Abstract This study proposes a simple multiresidue liquid chromatography–diode array detector (LC–DAD) method capable of determining seven macrolide antibiotics in samples of liver and kidney animals at concentrations lower than those allowed by current legislation. Samples were prepared by homogenizing the tissue with EDTA–McIlvaine's buffer and extracted with an Oasis HLB cartridge. The consumption of organic solvent during extraction was minimum. The analytes were detected by LC–DAD and also by liquid chromatography–mass spectrometry with electrospray ionization (LC–(ESI)MS). The method was specific, stable and robust enough for the required purposes. The DAD method was validated in acco…

AnalyteChromatographyChemistryElectrospray ionizationOrganic ChemistryReproducibility of ResultsGeneral MedicineKidneySensitivity and SpecificityBiochemistryHigh-performance liquid chromatographyAnti-Bacterial AgentsAnalytical ChemistryLiverCalibrationAnimalsmedia_common.cataloged_instanceSample preparationEuropean UnionMacrolidesSolid phase extractionEuropean unionQuantitative analysis (chemistry)Antibacterial agentmedia_commonJournal of Chromatography A
researchProduct

Evaluation of analytical performance of gas chromatography coupled with atmospheric pressure chemical ionization Fourier transform ion cyclotron reso…

2019

Abstract A new analytical method was established and validated for the analysis of eighteen halogenated flame retardants (HFRs)in food products. Gas chromatography (GC) coupled to Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) employing atmospheric pressure chemical ionization (APCI) was used for the identification and quantitation of contaminants. Intra-laboratory validation of the method was performed with respect to recovery, repeatability, linear calibration ranges, instrumental and method limits of quantitation (i-LOQ and m-LOQ), and trueness was verified where possible by analysis of reference materials (RMs). The validation results indicated recoveries of ana…

AnalyteEnvironmental EngineeringMaterials scienceFood SafetyHalogenationHealth Toxicology and Mutagenesis0208 environmental biotechnologyAtmospheric-pressure chemical ionization02 engineering and technology010501 environmental sciences01 natural sciencesFourier transform ion cyclotron resonanceGas Chromatography-Mass SpectrometryMass SpectrometryCalibrationHalogenated Diphenyl EthersEnvironmental ChemistryHumans0105 earth and related environmental sciencesFlame RetardantsDetection limitChromatographyFourier AnalysisPublic Health Environmental and Occupational HealthGeneral MedicineGeneral ChemistryRepeatabilityCyclotronsPollution020801 environmental engineeringFoodFood productsGas chromatographyFood AnalysisChemosphere
researchProduct

Mycotoxin contamination in laboratory rat feeds and their implications in animal research

2016

Compound feed is particularly vulnerable to multi-mycotoxin contamination. A method for the determination of 12 mycotoxins; enniatins A, A1, B, B1; aflatoxins B1, B2, G1, G2; OTA; ZEA; T-2 and HT-2 by liquid chromatography-tandem mass spectrometry has been developed and applied for the analysis of laboratory rat commercial feeds. The method trueness was checked by recovery assays at three different spiked levels (n = 9). Recoveries ranged from 73% to 112%, and the intra-day and inter-day precision were lower than 9% and 13%, respectively. Limits of quantitation were lower than 15 μg/kg. Twenty-seven laboratory rats feed samples showed multi-contamination by at least three up to six differen…

Animal ExperimentationSpectrometry Mass Electrospray IonizationAflatoxinMycotoxin contaminationHealth Toxicology and MutagenesisFood ContaminationToxicologychemistry.chemical_compound0404 agricultural biotechnologyLimit of DetectionTandem Mass SpectrometryAnimals LaboratoryLc ms msAnimalsFood scienceMycotoxinChemistryReproducibility of Results04 agricultural and veterinary sciencesMycotoxinsContaminationAnimal Feed040401 food scienceRatsLaboratory ratEnvironmental chemistryToxicology Mechanisms and Methods
researchProduct

A highly enantioselective abiotic receptor for malate dianion in aqueous solution

2006

The highly enantioselective molecular recognition of the malate dianion by a synthetic receptor in aqueous solution has been studied by potentiometric titrations, mass spectrometry (ESI-MS), diffusion measurements (PGSE NMR) and molecular modeling. Garcia-España Monsonis, Enrique, Enrique.Garcia-Es@uv.es

AnionsModels MolecularMalate dianionSpectrometry Mass Electrospray IonizationMagnetic Resonance SpectroscopyMolecular modelUNESCO::QUÍMICADiffusionPotentiometric titrationMalatesMolecular modelingAbiotic receptorMass spectrometry:QUÍMICA [UNESCO]CatalysisSubstrate SpecificityMolecular recognitionComputational chemistryMaterials ChemistryOrganic chemistryAqueous solutionReceptorAbiotic componentEnantioselectiveAqueous solutionMolecular StructureChemistrySpectrometryMeasurementsMetals and AlloysEnantioselective synthesisWaterHydrogen BondingStereoisomerismGeneral ChemistryGeneral MedicineUNESCO::QUÍMICA::Química macromolecularCombinatorial chemistrySurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialsSolutionsCeramics and CompositesPotentiometryEnantioselective ; Abiotic receptor ; Malate dianion ; Aqueous solution ; Spectrometry ; Measurements ; Molecular modeling:QUÍMICA::Química macromolecular [UNESCO]
researchProduct

Solid state anion–π interactions involving polyhalides

2013

The stabilization of polyhalides in the solid state with the support of electron-deficient pentafluorophenyl groups is described. Furthermore, a synthetic approach towards the sensitive tetraiodide dianion is described and ESI mass spectrometric evidence for its presence in solution is reported.

AnionsModels MolecularSpectrometry Mass Electrospray Ionizationmedicine.diagnostic_testChemistryElectrospray ionizationInorganic chemistryChemieSolid-stateAnalytical chemistryMass spectrometrymedicine.disease_causeMass spectrometricIonInorganic ChemistryHalogensSpectrophotometrymedicineSpectrophotometry Ultravioletta116UltravioletDalton Trans.
researchProduct

Anion-Exchange Properties of Trifluoroacetate and Triflate Salts of N-Alkylammonium Resorcinarenes

2016

The synthesis of N-benzyl- and N-cyclohexylammonium resorcinarene trifluoroacetate (TFA) and triflate (OTf) salt receptors was investigated. Solid-state analysis by single-crystal X-ray diffraction revealed that the N-alkylammonium resorcinarene salts (NARSs) with different upper substituents had different cavity sizes and different affinities for anions. Anion-exchange experiments by mixing equimolar amounts of N-benzylammonium resorcinarene trifluoroacetate and N-cyclohexylammonium resorcinarene triflate, as well as N-benzylammonium resorcinarene triflate and N-cyclohexylammonium resorcinarene trifluoroacetate showed that the NARS with flexible benzyl groups preferred the larger OTf anion…

AnionsModels MolecularsaltsPhenylalanineElectrospray ionizationInorganic chemistrySalt (chemistry)Benzylammonium CompoundsCrystallography X-Ray010402 general chemistryCrystal engineeringchemistry01 natural sciencesBiochemistryIonDioxanesX-rayPolymer chemistryTrifluoroacetic AcidAnion bindingta116N-AlkylammoniumMesylateschemistry.chemical_classificationanion-exchangeIon exchange010405 organic chemistryChemistryOrganic ChemistryGeneral ChemistryResorcinarene3. Good health0104 chemical sciencesCalixarenesTrifluoromethanesulfonateChemistry: An Asian Journal
researchProduct

Determination of low-molecular-mass aliphatic carboxylic acids and inorganic anions from kraft black liquors by ion chromatography.

2007

An ion chromatographic (IC) method with suppressed conductivity detection (CD) was developed and validated for the quantitative determination of several low-molecular-mass aliphatic mono- and dicarboxylic acids as their carboxylate anions together with some inorganic anions (chloride, sulfate, and thiosulfate) from kraft black liquors. To confirm the identification of some carboxylate anions which lack commercial model substances, a qualitative IC method with suppressed electrospray ionization mass spectrometry (ESI-MS) was also developed. The separations were performed on an IonPac AS 11-HC anion-exchange column operated at 25 degrees C within 25 min by a gradient elution with aqueous pota…

AnionsSpectrometry Mass Electrospray IonizationIon chromatographyCarboxylic AcidsIndustrial WasteBiochemistrySensitivity and SpecificityAnalytical Chemistrychemistry.chemical_compoundCarboxylateDetection limitThiosulfatePotassium hydroxideChromatographybiologyOrganic ChemistryReproducibility of ResultsGeneral MedicineReference StandardsMolecular WeightchemistrySodium hydroxideTextile Industrybiology.proteinBlack liquorOrganic anionChromatography LiquidJournal of chromatography. A
researchProduct