Three-dimensional superresolution by annular binary filters
1999
We present a new family of annular binary filters for improving the three-dimensional resolving power of optical systems. The filters, whose most important feature is their simplicity, permit to achieve a significant reduction, both in the transverse and in the axial direction, of the central lobe width of the irradiance point spread function of the system. The filters can be used for applications such as optical data storage or confocal scanning microscopy.
Enhancing spatial resolution in digital holographic microscopy by biprism structured illumination.
2014
A novel and efficient architecture of a structured-illumination digital holographic microscope (DHM) is presented. As the DHM operates at the diffraction limit, its spatial resolution on label-free imaging of transparent samples is improved by illuminating the sample with a structured illumination produced by a Fresnel's biprism. The theoretical analysis of the method forecasts a twofold improvement of the spatial resolution. The proposed method requires only two images to improve the spatial resolution, which eases the process of unmixing the high-resolution components by means of an unknown phase-shift procedure. Numerical modeling and experimental results validate the theoretical finding…
X-ray CT analyses, models and numerical simulations: a comparison with petrophysical analyses in an experimental CO<sub>2</sub&a…
2016
Abstract. An essential part of the collaborative research project H2STORE (hydrogen to store), which is funded by the German government, was a comparison of various analytical methods for characterizing reservoir sandstones from different stratigraphic units. In this context Permian, Triassic and Tertiary reservoir sandstones were analysed. Rock core materials, provided by RWE Gasspeicher GmbH (Dortmund, Germany), GDF Suez E&P Deutschland GmbH (Lingen, Germany), E.ON Gas Storage GmbH (Essen, Germany) and RAG Rohöl-Aufsuchungs Aktiengesellschaft (Vienna, Austria), were processed by different laboratory techniques; thin sections were prepared, rock fragments were crushed and cubes of …
Electrochemistry of iron oxide pigments (earths) from pictorial microsamples attached to graphite–polyester composite electrodes
2001
The electrochemical response of different iron pigments attached to graphite–polyester composite electrodes is described. Characteristic differential pulse voltammetric profiles were obtained for green earth, iron oxide red, Mars black, ochre yellow, Sienna raw, umber raw and Van Dyke brown. Proton-assisted reductive dissolution processes occur at the three-phase boundary of the substrate electrode–attached solid–electrolyte solution system. Microsamples extracted from polychromed sculptures, canvas paintings, wall paintings, altarpieces and panel paintings from Spain, Ethiopia and Italy from the 12th to the 20th centuries were electrochemically identified in agreement with polarized light …
Director orientation in chevron surface-stabilized ferroelectric liquid crystal cells. Verification of orientational binding at the chevron interface…
1990
Abstract We present results of theoretical modelling and experimental study of director distributions and the associated optical properties of chevron surface stabilized ferroelectric liquid crystal (SSFLC) cells. Chevron cells are modelled as being two stacked FLC slabs, described by distinct orientation distributions of the director [ncirc]-polarization P([ncirc] – P) couple. In each slab the [ncirc] – P distribution is governed by bulk Frank elastic and electric field-induced torques and by surface torques at the FLC-solid interface and at the chevron interface, where the two distributions are coupled. The optical properties of such structures are calculated numerically and the results t…
Surface induced smectic order in ionic liquids - an X-ray reflectivity study of [C(22)C(1)im](+)[NTf2](-)
2017
Physical chemistry, chemical physics 19(39), 26651 - 26661 (2017). doi:10.1039/C7CP04852A
Magneto-optical linear dichroism in threshold photoemission electron microscopy of polycrystalline Fe films.
2000
Magnetic linear dichroism in threshold photoemission has been exploited to obtain magnetic contrast in a photoemission electron microscope using a mercury arc lamp. The dichroism at threshold can be described similar to the magneto-optical Kerr effect in the region of visible light. The asymmetry of electron intensity observed for a 100 nm polycrystalline Fe film on silicon is A=(0.37+/-0.05)%. The asymmetry occurs for the geometry of the transverse Kerr effect. For unpolarized light the asymmetry was about half the value observed for linearly polarized light. Threshold photoemission microscopy has a large potential for high resolution magnetic domain imaging with fast data acquisition.
Thermotropic polyesters with mesogenic groups based on substituted hydroquinone units and highly flexible siloxan spacer in the main chain
1984
New thermotropic Polyesters having mesogenic groups based on substituted hydroquinone units and highly flexible oligosiloxan spacer in the main chain, are synthesized and characterized. The mesophase formed at low temperature are studied by differential scanning calorimetry (DSC) and polarized light microscopy. The liquid crystalline behaviour of these polyesters, particulary their transition temperatures and the mesophase width could be explained on the basis of their structural features.
Morphological patterns of circumpulpal dentin affected by radiation-related caries
2020
Background The aim of this work was to evaluate the microscopic characteristics through polarized light microscopy, scanning electron microscopy and the mineral content of circumpulpal dentin of irradiated (IT) and non-irradiated teeth (NIT), with deep caries that reached the root canal. Material and methods A total of 25 IT were analyzed macroscopically, and radiographed. 5 NIT were used as controls. Two 100-μm-thick sections, per specimen, were evaluated in a polarized light microscopy and a scanning electron microscope. Demographics and clinical data were collected. Results The results did not demonstrate distinct morphology of the IT compared with NIT. Mineral content values by weight p…