Search results for " misure"
showing 10 items of 421 documents
Harmonic sources detection in power systems via nonactive power measurements according to IEEE Std. 1459-2010: theoretical approach and experimental …
2010
In this paper an enhanced decision-making strategy is presented for the detection of harmonic sources in power systems able to detect also which is the prevailing nature of the disturbance (nonlinearity or unbalance). It makes use of some simple indices, which are evaluated by means of the measurements of some nonactive power quantities, proposed by the authors and derived from the approach of the IEEE Std. 1459-2010. The decision-making rules for the proposed strategy are presented and discussed by means of simulation and experimental tests. The results obtained are presented, showing the effectiveness of the proposed strategy for the detection of the dominant harmonic source upstream or d…
A Line Impedance Calculator Based on a G3 PLC Modem Platform
2022
Power line communication (PLC) is one of the most today used technologies for both automatic meter reading and many other smart grid applications. In this framework, a characterization of the electrical network in the PLC frequency range is needed in terms of impedance measurement and received signal level. This can allow choosing the most suitable and less noisy frequency ranges for PLC transmission. Usually, these characterization measurements are performed with dedicated instrumentation and in the absence of mains voltage. This article wants to propose an alternative solution, which allows these kinds of measurements to be performed using electronic boards currently used as on-field appl…
Uncertainty evaluation in load flow analysis: real MV distribution networks case studies
2018
This work investigates the measurement uncertainty impact on load flow analysis in medium voltage (MV) distribution networks. The considered algorithm is a simplified load flow algorithm (LFA), developed by authors, which is based on the load power measurements at each secondary substation and one voltage measurement at the slack bus (i.e. the voltage at the MV bus bars of the primary substation). In the viewpoint of a real implementation, to reduce monitoring system costs, the LFA makes use of low voltage (LV) load power measurements for all the substations except those of MV users, where MV transducers are usually already installed. The uncertainties on LFA input quantities (load powers a…
THERP and HEART integrated methodology for human error assessment
2014
Medical errors are one of the leading causes of death and injury in radiation therapy administration as reported in the literature. This point out an overall deficiency in management allowing patient treatment in the absence of suitable quality assurance processes. Clinical records of major accidental exposure events in radiotherapy show that there is a combination of factors contributing to the accident such as deficient staff training, lack of independent checks, lack of quality control procedures, and absence of overall supervision. Another finding is that training generally addresses only normal situations and does not prepare radiotherapy staff for unusual situations, resulting in a la…
PROVE ED ESPERIMENTI DI VERIFICA DELLA SICUREZZA DEL REATTORE NUCLEARE DI RICERCA AGN-201 “COSTANZA”
2011
The “Zero Power” Nuclear Reactor AGN-201 “Costanza” available at Nuclear Engineering Department of Palermo University is a valuable tool for educational purpose and research. Besides being a useful tool for training of operators, without the time period limits on start-up and shut-down of the larger reactors, it allows the study of some phenomena regarding nuclear reactor physics, applied neutronics, neutron dosimetry, nuclear measurements as well as testing of nuclear instrumentation and methods. The experience of work and the obtained results highlight the simplicity of AGN-201 reactor control, its intrinsic safety and its overall versatility in various fields of Nuclear Engineering.
Dangerous Effects Induced on Power MOSFETs by Terrestrial Neutrons
2013
This paper investigates the effects that terrestrial neutrons can induce on power MOSFETs when they are biased during their normal working conditions especially in inverters for photovoltaic applications. After a brief review of power MOSFETs failure phenomena caused by neutron irradiation (with emphasis on so called “Single Event Effects” (SEE)), the results of an accelerated test performed with the Am-Be source at the University of Palermo are discussed.
Un wattmetro basato su schede di acquisizione commerciali per misure in regime distorto. Sviluppo dello strumento e prove preliminari
2012
Un campione di potenza basato su schede di acquisizione commerciali. Prove sperimentali e valutazione dell'incertezza
2011
Time domain symmetry parameters analysis for series arc fault detection
2022
This paper presents a feasibility study of exploiting the symmetry of some parameters for series arc fault detection in electrical circuits. The considered parameters are defined in the time domain and they are based on the current signal derivative and the evaluation of cross-correlation between subsequent observation windows. The analysis is carried out for AC systems, starting from an experimental characterization, which has been carried out in accordance with the Standard UL 1699 requirements for "unwanted tripping tests"and "operation inhibition tests"of arc fault circuit interrupters (AFCIs). The results obtained in different load conditions show that the proposed parameters can be us…
Uno strumento virtuale per il monitoraggio e il controllo di un impianto fotovoltaico a concentrazione
2014
In questa memoria si presenta una sintesi delle attività condotte nell'ambito del progetto SERPICO ("Sviluppo E Realizzazione di Prototipi di Inverter per impianti fotovoltaici a Concentrazione", PO-FESR Sicilia 2007-2013, Misura 4.1.1.2). Il progetto ha riguardato lo sviluppo di un prototipo di impianto fotovoltaico-termico a concentrazione e del relativo sistema di monitoraggio e controllo. Tale sistema permette di acquisire le quantità sia elettriche che termiche. Inoltre esso implementa un algoritmo per l'inseguimento solare utilizzato per ottimizzare la produzione di potenza.