SU-F-T-13: Transit Dose Comparisons for Co-60 and Ir-192 HDR Sources
2016
Purpose: The purpose of this study is to compare the transit dose due to the movement of high dose rate (HDR) Ir-192 and Co-60 sources along the transfer tube. This is performed by evaluating air-kerma differences in the vicinity of the transfer tube when both sources are moved with the same velocity from a HDR brachytherapy afterloader into a patient. Methods: Monte Carlo simulations have been performed using PENELOPE2014. mHDR-v2 and Flexisource sources have been considered. Collisional kerma has been scored. The sources were simulated within a plastic catheter located in an infinite air phantom. The movement of the seed was included by displacing their positions along the connecting cath…
Comparaison de la mesure des déformations de fantômes de l’aorte à partir d’image obtenues par IRM et stéréovision
2015
International audience; The study of the wall strain distribution could be helpful to improve the decision criterion for surgery of aortic aneurysm. Recently, numerical simulations can complete the data obtained from imaging measurement in order to develop reliable models. However, the used medical imaging tools are not experimentally validated, in metrological point of view. The aim of this study focused on accuracy and reliability of measurement obtained from kinetic MR sequences. The measures of deformations from MRI were compare to those obtained from stereovision system. Cylindrical phantom of silicone material similar to arterial behavior simulated a symmetric aneurysm was designed. A…
Optical gratings induced by field-free alignment of molecules
2006
We analyze the alignment of molecules generated by a pair of crossed ultra-short pump pulses of different polarizations by a technique based on the induced time-dependent gratings. Parallel polarizations yield an intensity grating, while perpendicular polarizations induce a polarization grating. We show that both configurations can be interpreted at moderate intensity as an alignment induced by a single polarized pump pulse. The advantage of the perpendicular polarizations is to give a signal of alignment that is free from the plasma contribution. Experiments on femtosecond transient gratings with aligned molecules were performed in CO2 at room temperature in a static cell and at 30 K in a …
SU-GG-T-70: A Dosimetric Study of the MicroSelectron HDR Ir-192 Brachytherapy Source
2010
Purpose: Recently the manufacturer of the mHDR‐v2 HDR Ir‐192 brachytherapy source clarified design changes that may alter the existing dosimetric data for this source. The object of this study was to obtain new dose rate tables following the TG‐43 formalism and to provide these data in close proximity to the source with high spatial resolution including the electron dosimetric contributions from Ir‐192 disintegration. Methods and Material: To study the source we used three different Monte Carlo codes: MCNP5, GEANT4, and Penelope. The source was located inside a 40 cm radius water phantom. Dose and kerma were obtained using 0.1 mm thick voxels to provide high‐resolution dosimetry near the so…
Dosimetry revisited for the HDR I192r brachytherapy source model mHDR-v2
2010
Purpose: Recently, the manufacturer of the HDR I 192 r mHDR-v2 brachytherapysource reported small design changes (referred to herein as mHDR-v2r) that are within the manufacturing tolerances but may alter the existing dosimetric data for this source. This study aimed to (1) check whether these changes affect the existing dosimetric data published for this source; (2) obtain new dosimetric data in close proximity to the source, including the contributions from I 192 r electrons and considering the absence of electronic equilibrium; and (3) obtain scatterdose components for collapsed cone treatment planning system implementation. Methods: Three different Monte Carlo(MC) radiation transport co…
SU-E-T-509: DICOM Test Case Plans for Model-Based Dose Calculations Methods in Brachytherapy
2013
Purpose: The TG‐186 report provides guidance to early adopters of model‐based dose calculation algorithms (MBDCAs) for brachytherapy. A charge of the AAPM‐ESTRO Working Group on MBDCA is to develop well‐defined test case plans, available as references for the software commissioning process to be performed by end‐users. The aim of this work is to develop test case plans for a generic HDR 192 Ir source alone and in combination with a vaginal cylinder applicator with 180° tungsten‐alloy shielding in a DICOM‐based water phantom. Methods: A DICOM CT dataset was created with a 30 cm diameter water sphere surrounded by air. The voxel size was 1.33×1.33×1.33 mm3 for evaluating absorbed dose rate (c…
Dosimetric study of the 15mm ROPES eye plaque
2004
The main aim of this paper is to make a study of dose-rate distributions obtained around the 15 mm, radiation oncology physics and engineering services, Australia (ROPES) eye plaque loaded with {sup 125}I model 6711 radioactive seeds. In this study, we have carried out a comparison of the dose-rate distributions obtained by the algorithm used by the Plaque Simulator (PS) (BEBIG GmbH, Berlin, Germany) treatment planning system with those obtained by means of the Monte Carlo method for the ROPES eye plaque. A simple method to obtain the dose-rate distributions in a treatment planning system via the superposition of the dose-rate distributions of a seed placed in the eye plaque has been develo…
A 20-channel receive-only mouse array coil for a 3 T clinical MRI system
2011
A 20-channel phased-array coil for MRI of mice has been designed, constructed, and validated with bench measurements and high-resolution accelerated imaging. The technical challenges of designing a small, high density array have been overcome using individual small-diameter coil elements arranged on a cylinder in a hexagonal overlapping design with adjacent low impedance preamplifiers to further decouple the array elements. Signal-to-noise ratio (SNR) and noise amplification in accelerated imaging were simulated and quantitatively evaluated in phantoms and in vivo mouse images. Comparison between the 20-channel mouse array and a length-matched quadrature driven small animal birdcage coil sh…
A mammographic phantom image reconstruction through Monte Carlo techniques
2005
Mammographic phantoms are employed during quality control test in breast screening locations and other health centres. These quality controls are performed to achieve the image quality required to detect breast abnormalities, ensuring the minimum risk to radiographied women. The aim of this study is the development of a methodology to reproduce the image of a mammogram during a routine exposure in a breast screening programme. In a first step, the CIRS 11A (MAMMO PHANTOM SP01) mammographic phantom has been simplified and modelled with the Monte Carlo transport code MCNP-4c2. Different tallies (F2 and F5) have been used to score the photon flux under the phantom, and a group of aluminium lay…
Diagrammatic expansion for positive spectral functions beyond GW : Application to vertex corrections in the electron gas
2014
We present a diagrammatic approach to construct self-energy approximations within many-body perturbation theory with positive spectral properties. The method cures the problem of negative spectral functions which arises from a straightforward inclusion of vertex diagrams beyond the GW approximation. Our approach consists of a two-steps procedure: we first express the approximate many-body self-energy as a product of half-diagrams and then identify the minimal number of half-diagrams to add in order to form a perfect square. The resulting self-energy is an unconventional sum of self-energy diagrams in which the internal lines of half a diagram are time-ordered Green's functions whereas those…