TH-C-AUD A-07: Evaluation of the Correction Factor Due to the Lack of Full Scatter Conditions in Cs-137 and Ir-192 Brachytherapy Dosimetric Studies
2008
Purpose: Use of a finite phantom to derive dose rate distributions around brachytherapysources implies a lack of backscattering material near the phantom periphery. Conventional planning algorithms and newly‐developed 3D correction algorithms are based on physics data under full scatter conditions. Presently, most published Monte Carlodosimetric studies have been obtained using either a spherical phantom (15cm in radius) or a cylinder phantom (40×40cm2). The study objective was to derive a simple relationship to correlate the radial dose function, g(r), obtained for each one of these phantoms to that obtained for an unbounded phantom. Method and Materials: Assuming bare point sources of 137…
WE-C-108-08: Organ Doses in a Male Phantom Undergoing High-Dose-Rate Brachytherapy Applied to the Prostate
2013
Purpose: The aim of this study was to obtain equivalent doses to radiosensitive organs when applying high‐dose‐rate (HDR) brachytherapy to the prostate using60 Co or 192 Ir sources, and in comparison to external‐beam radiotherapy (EBRT) modalities. Methods: Monte Carlo simulations in Geant4 were performed using a voxelized adult reference man described in Publication 110 by the International Commission on Radiological Protection (ICRP). Point sources of 60Co or 192Ir with photon energy spectra corresponding to those exiting their capsules were placed in the center of the prostate. Equivalent doses per therapeutic absorbed dose to the prostate were obtained in several radiosensitive organs. …
Monte Carlo dosimetric study of Best Industries and Alpha Omega Ir-192 brachytherapy seeds
2004
Ir-192 seeds are widely used in the USA for low dose rate interstitial brachytherapy. There are two commercially available models: those manufactured by Best Industries filtered with stainless steel, and those manufactured by Alpha-Omega seeds filtered with Pt. Newly developed 3D correction algorithms for brachytherapy are based on dosimetry data obtained on unbounded phantom size, allowing corrections for heterogeneities and actual tissue boundaries. Published dosimetric datasets for both seeds have been obtained under bounded conditions. The aim of the present study is to obtain dosimetric datasets for these seeds under full scatter conditions. The Monte Carlo GEANT4 code has been used to…
Combined Endo- and Exoscopic Semi-robotic Manipulator System for Image Guided Operations
2006
This paper describes the development of a robotic assistance system for image guided operations. To minimize operation time, a multimodal user interface enables freehand robotic manipulation of an extracorporeal stereoscopic digital camera (exoscope) and an endoscope. The surgeon thereby wears a head-mounted unit with a binocular display, a head tracker, a microphone and earphones. Different view positioning and adjustment modes can be selected by voice and controlled by head rotation while pressing a miniature confirmation button with a finger. Initial studies focused on the evaluation and optimization of the intuitiveness, comfort and precision of different modes of operation, including a…
Trans-cranial Magnetic Resonance-guided Focused UltraSound (tcMRgFUS) system integrated with a 1.5T: an SNR study on DQA phantoms
2018
Background: In recent years transcranial Magnetic Resonance-guided Focused Ultrasound Surgery (tcMRgFUS) treatments have been performed only using 3T units. Since following some internal analysis, planning images obtained using a 1.5T MRI’s body RF coil (as usually done with 3T systems) showed generally reasonable quality in terms of anatomy visualization and SNR but thermal images noise was above acceptable standard for treatments, a dedicated 2-channels head coil was developed (InSightec Ltd.) to ensure an adequate signal-to-noise ratio (SNR). Hence, we present the imaging protocol and the technological methods successfully used with the world-first installation of a certified tcMRgFUS sy…
Technical note : Simulation of lung counting applications using Geant4
2023
A Geant4 simulation package has been developed to investigate and test detector configurations for lung counting applications. The objective of this study was to measure radiation emitted from the human body and to make a qualitative comparison of the results of the simulation with an experiment. Experimental data were measured from a plastic phantom with a set of lungs containing 241Am activity. For comparison, simulations in which 241Am activity was uniformly distributed inside the lungs of the ICRP adult reference computational phantom were made. The attenuation of photons by the chest wall was simulated and from this photopeak ef-ficiency and photon transmission were calculated as a fun…
IC‐P‐050: The European diffusion tensor imaging study in dementia (EDSD): Physical phantom study and multimodal clinical study on the diagnosis of Al…
2012
Implementation of dosimetry equipment and phantoms at the MedAustron light ion beam therapy facility
2017
Purpose: To describe the implementation of dosimetry equipment and phantoms into clinical practice of light ion beam therapy facilities. This work covers standard dosimetry equipment such as computerized water scanners, films, 2D-array, thimble and plane parallel ionization chambers, but also dosimetry equipment specifically devoted to the pencil beam scanning delivery technique such as water columns, scintillating screens or multi-layer ionization chambers. Method: Advanced acceptance testing procedures developed at MedAustron and complementary to the standard acceptance procedures proposed by the manufacturer are presented. Detailed commissioning plans have been implemented for each piece…
Verification of a commercial implementation of the Macro-Monte-Carlo electron dose calculation algorithm using the virtual accelerator approach.
2009
Abstract In this work, the accuracy of the implementation of the Macro Monte Carlo electron dose calculation algorithm into the radiation therapy treatment planning system Eclipse is evaluated. This implementation – called eMC – uses a particle source based on the Rotterdam Initial Phase-Space model. A three-dimensional comparison of eMC calculated dose to dose distributions resulting from full treatment head simulations with the Monte Carlo code package EGSnrc is performed using the ‘virtual accelerator’ approach. Calculated dose distributions are compared for a homogeneous tissue equivalent phantom and a water phantom with air and bone inhomogeneities. The performance of the eMC algorithm…
2017
Objective Computer-aided-surgery in ENT surgery is mainly used for sinus surgery but navigation accuracy still reaches its limits for skull base procedures. Knowledge of navigation accuracy in distinct anatomical regions is therefore mandatory. This study examined whether navigation accuracy can be improved in specific anatomical localizations by using hybrid registration technique. Study design Experimental phantom study. Setting Operating room. Subjects and methods The gold standard of screw registration was compared with automatic LED-mask-registration alone, and in combination with additional surface matching. 3D-printer-based skull models with individual fabricated silicone skin were u…