Search results for " press"
showing 10 items of 4213 documents
PREVALENCE AND ASSOCIATIONS OF MYELINATED RETINAL NERVE FIBERS
2016
PURPOSE To determine the prevalence, ocular, and systemic associations of myelinated retinal nerve fibers (MRNF) in a Caucasian cohort. METHODS The Gutenberg Health Study (GHS) is a population-based, prospective cohort study encompassing 15,010 subjects in Germany. Gutenberg Health Study participants, aged 35 to 74 years, stratified for gender, decades of age, and residence were examined for ophthalmologic and systemic conditions. Optic disc centered and macular photographs were reviewed for the presence of MRNF. RESULTS In 25,728 eyes of 12,906 participants (86.0% of the cohort), the prevalence of MRNF was 0.4%. In a binary logistic regression analysis, MRNF was positively associated with …
Tolerability of 24-hour intraocular pressure monitoring of a pressure-sensitive contact lens.
2013
Purpose To investigate tolerability and safety of a new diagnostic device for 24-hour intraocular pressure monitoring in healthy subjects and age-matched glaucoma patients. Patients and methods Twenty healthy subjects (group 1) and 20 age-matched glaucoma patients (group 2) were included in this prospective, single-center, open, observational parallel group study. The SENSIMED Triggerfish Sensor is a soft disposable contact lens embedding a telemetry chip and strain gauge sensor for continuous intraocular pressure monitoring. The Sensor was placed in 1 eye for 24 hours. Tolerability was evaluated using a visual analog scale (range, 0 to 100; 0=no discomfort; 100=very severe discomfort). Saf…
Risk factors of ocular hypertension and glaucoma. The Casteldaccia Eye Study.
1994
A case-control study was planned as a part of the Casteldaccia Eye Study in order to investigate about risk factors of ocular hypertension and glaucoma. Cases were 44 subjects with glaucoma or intraocular pressure of 24 mm Hg or more. Controls were 220 subjects with intraocular pressure of 20 mm Hg or less and no signs of glaucoma. A number of environmental, behavioral, systemic and ocular variables were studied. Among the others we investigated the following: sunlight exposure, smoking, alcohol intake, pregnancies, systemic hypertension, diabetes, use of corticosteroids, refractive status, anterior chamber depth, lens nuclear sclerosis, iris color and texture. After univariate analysis the…
Intraocular pressure after small incision cataract surgery: temporal sclerocorneal versus clear corneal incision.
2001
To compare intraocular pressure (IOP) after phacoemulsification and foldable intraocular lens (IOL) implantation using a temporal sclerocorneal or clear corneal incision.Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany.One hundred patients (100 eyes) with cataract having phacoemulsification with posterior chamber IOL implantation were randomly assigned to receive a temporal sclerocorneal or clear corneal tunnel incision. Intraocular pressure was measured preoperatively and 6 hours, 1, 2, and 3 days, and 5 months postoperatively. Statistical significance was determined by nonparametric group comparisons using 2-sample random Wilcoxon tests.Six hours postoperatively,…
Falsely elevated intraocular pressure due to increased central corneal thickness
1999
PURPOSE: To evaluate whether ocular hypertensive subjects have a higher central corneal thickness than other individuals. METHODS: In this prospective study, 48 subjects with ocular hypertension, 63 patients with open-angle glaucoma, 56 nonglaucomatous patients with diabetes mellitus, and 106 control subjects were evaluated. Corneal thickness was measured by ultrasound pachymetry, and intraocular pressure was determined by Goldmann applanation tonometry. RESULTS: Central corneal thickness was significantly higher in the ocular hypertensive subjects, mean +/- S.D., 592+/-39 microm, than in the patients with glaucoma (536+/-34 microm), the nonglaucomatous patients with diabetes mellitus (550+…
Corneoscleral contact lenses for visual rehabilitation after keratoplasty surgery.
2019
Abstract Purpose To report the use of corneoscleral lenses (CSL) in keratoconus patients who were unsatisfied with their visual outcomes after keratoplasty surgery. Methods Eleven consecutive cases with unsatisfactory vision with spectacles, due to irregular astigmatism, preferred to try CSL before SL due to handling or economic issues. An eye examination included refraction and visual acuity assessment, anterior eye biomicroscopy, ocular fundus examination, corneal topographic analysis, endothelial-cell count (ECC) and evaluation of corneal biomechanical parameters (corneal resistance factor, CRF; corneal hysteresis, CH; corneal-compensated intraocular pressure, IOPcc). The fitting process…
Impact of Corneoscleral Contact Lens Usage on Corneal Biomechanical Parameters in Keratoconic Eyes
2019
Objective To analyze the changes in corneal biomechanical parameters of keratoconic eyes with and without intracorneal ring segment (ICRS) implants after 1 year of corneoscleral contact lens (CScL) wear. Methods Seventy-four eyes of 74 patients were divided into three groups: healthy subjects (29 eyes, control group), and 2 groups of subjects with keratoconic eyes (one group of 20 eyes with ICRS implants and one of 25 eyes without them), which were fitted with CScL. Corneal hysteresis (CH), corneal resistance factor (CRF), and corneal-compensated intraocular pressure (IOPcc) were evaluated before fitting CScL and after 1 year of CScL wear. In addition, endothelial cell count (ECC) and centr…
Tidal Volume Estimation during Helmet Noninvasive Ventilation: an Experimental Feasibility Study
2019
AbstractWe performed a bench (BS) and human (HS) study to test the hypothesis that estimation of tidal volume (VT) during noninvasive helmet pressure support ventilation (nHPSV) would be possible using a turbine driven ventilator (TDV) coupled with an intentional leak single-limb vented circuit. During the BS a mannequin was connected to a lung simulator (LS) and at different conditions of respiratory mechanics, positive end expiratory pressure (PEEP) levels and leaks (30, 50 and 80 L/min). All differences were within the 95% limits of agreement (LoA) in all conditions in the Bland-Altman plot. The overall bias (difference between VT measured by TDV and LS) was 35 ml (95% LoA 10 to 57 ml), …
The P600-as-P3 hypothesis revisited: single-trial analyses reveal that the late EEG positivity following linguistically deviant material is reaction …
2014
The P600, a late positive ERP component following linguistically deviant stimuli, is commonly seen as indexing structural, high-level processes, e.g. of linguistic (re)analysis. It has also been identified with the P3 (P600-as-P3 hypothesis), which is thought to reflect a systemic neuromodulator release facilitating behavioural shifts and is usually response time aligned. We investigated single-trial alignment of the P600 to response, a critical prediction of the P600-as-P3 hypothesis. Participants heard sentences containing morphosyntactic and semantic violations and responded via a button press. The elicited P600 was perfectly response aligned, while an N400 following semantic deviations …
Association of Common Variants in NPPA and NPPB with Circulating Natriuretic Peptides and Blood Pressure
2009
We examined the association of common variants at the NPPA-NPPB locus with circulating concentrations of the natriuretic peptides, which have blood pressure-lowering properties. We genotyped SNPs at the NPPA-NPPB locus in 14,743 individuals of European ancestry, and identified associations of plasma atrial natriuretic peptide with rs5068 (P = 8 x 10(-70)), rs198358 (P = 8 x 10(-30)) and rs632793 (P = 2 x 10(-10)), and of plasma B-type natriuretic peptide with rs5068 (P = 3 x 10(-12)), rs198358 (P = 1 x 10(-25)) and rs632793 (P = 2 x 10(-68)). In 29,717 individuals, the alleles of rs5068 and rs198358 that showed association with increased circulating natriuretic peptide concentrations were a…