Search results for " press"
showing 10 items of 4213 documents
Network for blood pressure research in children and adolescents: A Cost Action
2020
COST Action will contribute pioneering research going beyond the state of the art and facing the most critical challenges affecting high BP in children and adolescents. HyperChildNET will go beyond the Working Group during its 4-year duration
Chronic thromboembolic pulmonary hypertension from the perspective of patients with pulmonary embolism
2018
Chronic thromboembolic pulmonary hypertension (CTEPH) is a rare but feared long-term complication of acute pulmonary embolism (PE), although CTEPH may occur in patients with no history of symptomatic venous thromboembolism. It represents the most severe presentation of the so-called 'post-PE syndrome', a phenomenon of permanent functional limitations after PE caused by deconditioning after PE or ventilatory or circulatory impairment as a result of unresolved pulmonary artery thrombi. Because the post-PE syndrome may occur in up to 50% of PE survivors, and CTEPH tends to have an insidious and non-specific clinical presentation, CTEPH is often not diagnosed or diagnosed after a very long dela…
Unilateral Accessory Sacroiliac Joint with Bone Marrow Edema Mimicking Sacroiliitis.
2018
Accessory sacroiliac joint (SIJ) is described as a common anatomical variant, identified in 13–18% and up to 40% of the general population1,2. It can be unilateral or bilateral and is related to aging, obesity, or women with multiple deliveries2,3. The patient, a 53-year-old white woman, presented with low back pain and left buttock pain for 6 months. She had no fever and local pressure on left SIJ reproduced …
The Impact of Venous Pressure on FFR: Do Diuretics Affect FFR?
2016
Central venous pressure influences FFR measurements because it decreases the perfusion gradient distal to the stenosis proportionally more than it does proximal to it. The impact of central venous pressure is minimal for normal pressure values and for FFR values away from the threshold. However, in conditions where FFR is close to 0.80 and central venous pressure is high, it might play an important role in reclassifying stenoses from not relevant to relevant.
Information transfer and information modification to identify the structure of cardiovascular and cardiorespiratory networks
2017
To fully elucidate the complex physiological mechanisms underlying the short-term autonomic regulation of heart period (H), systolic and diastolic arterial pressure (S, D) and respiratory (R) variability, the joint dynamics of these variables need to be explored using multivariate time series analysis. This study proposes the utilization of information-theoretic measures to measure causal interactions between nodes of the cardiovascular/cardiorespiratory network and to assess the nature (synergistic or redundant) of these directed interactions. Indexes of information transfer and information modification are extracted from the H, S, D and R series measured from healthy subjects in a resting…
A nonlinear biomechanical model for evaluation of cerebrospinal fluid shunt systems.
1994
In view of complications arising from physical properties of cerebrospinal fluid shunts, a biomechanical model of hydrocephalus was set up to study in vivo parameters that may influence their function. These include: intracranial pressure, compliance and pulses, intrathoracic, intra-abdominal, and subcutaneous pressures, and the effects of siphonage and repeated valve flushing. Each of these factors was studied separately upon shunt implantation in the model. Results of testing of a sample low-pressure valve with antisiphon device conformed with consumer information in regard to valve opening pressure and pressure flow measurements. No customer information, however, was supplied concerning …
Histopathologic Findings in Early Encapsulated Blebs of Young Patients Treated With the Ahmed Glaucoma Valve
2010
Objective/aim Uncontrolled glaucoma presents a challenge for the ophthalmic surgeon especially in children and juvenile patients. For many patients who have undergone failed surgical procedures before, episcleral implants remain the last choice. Encapsulated blebs forming over antiglaucoma devices present a complication leading to malfunctioning or even failure with reincrease in intraocular pressure. We report our histopathologic findings of such blebs developing around the Ahmed glaucoma valve (AGV) after a short time period in young patients. Materials and methods Nine young patients (2 to 17 y of age) with otherwise uncontrollable glaucoma were treated with AGV (models FP-7 and FP-8, si…
Assessment of environmental AMD risk factors in a population of patients suffering from stroke and myocardial infarction
2010
International audience; Purpose: Stroke and myocardial infarction are common diseases occurring in patients suffering from Age Macular Degeneration (AMD). We assessed the rate of AMD and AMD risk factors in patients suffering from recent stroke or myocardial infarction. Methods: Patients suffering from a recent stroke or myocardial infarction (less than 1 month) benefited from a thorough ophthalmic examination with the following measurements and evaluations: visual acuity, intraocular pressure, fundus photography, Raman spectroscopy and macular OCT. In the same time a food questionnaire was dispensed. Finally, blood samples to measure fatty acids and lutein were performed. Results: 74 patie…
2017
Purpose Intraocular pressure (IOP) fluctuation is considered as a risk factor for glaucoma progression. We investigated IOP values and IOP fluctuation before and after trabeculectomy (TE) with mitomycin C (MMC) measured by 48-hour diurnal-nocturnal-IOP-profiles (DNP). Methods Pre- and postoperative DNPs of 92 eyes undergoing primary TE with MMC were analysed. Each 48-hour IOP-profile involved 10 IOP measurements (8:00 a.m., 2:00 p.m., 6:00 p.m., and 9:00 p.m. in sitting and at 00:00 in supine position). The “preoperative DNP” was performed a few weeks before TE. The “postoperative DNP” was performed at least six months (range: 6 months—2 years) after TE. Mean IOP values and IOP fluctuations…
Lipid profile of tenon's capsule in glaucoma patients
2009
International audience; Purpose: To provide data on the lipid profile of the Tenon’s capsule in Human glaucomatous eyes and to establish possible relationships with the short term outcome of filtration surgery. Methods: Fragments of Tenon’s capsule were collected during glaucoma surgery in patients suffering from open angle glaucoma (10 trabeculectomies and 17 non penetrating deep sclerectomies). The lipid profile of the human samples was determined by gas chromatography. A successful outcome after glaucoma surgery was defined by an intraocular pressure (IOP) ≤ 15 mmHg at 6 months without any IOP‐lowering agent. Results: We included 27 patients (12 males, 15 females) with a mean age of 65.5…