Search results for " processing"
showing 10 items of 7549 documents
Interindividual synchronization of brain activity during live verbal communication
2013
Verbal social interaction plays an important role both in the etiology and treatment of psychiatric disorders. However, the neural basis of social interaction has primarily been studied in the individual brain, neglecting the inter-individual perspective. Here, we show inter-individual neuronal coupling of brain activity during live verbal interaction, by investigating 11 pairs of good female friends who were instructed to speak about autobiographical life events during simultaneous fMRI acquisition. The analysis revealed that the time course of neural activity in areas associated with speech production was coupled with the time course of neural activity in the interlocutor's auditory corte…
Transient and sustained BOLD signal time courses affect the detection of emotion-related brain activation in fMRI.
2014
A tremendous amount of effort has been dedicated to unravel the functional neuroanatomy of the processing and regulation of emotion, resulting in a well-described picture of limbic, para-limbic and prefrontal regions involved. Studies applying functional magnetic resonance imaging (fMRI) often use the block-wise presentation of stimuli with affective content, and conventionally model brain activation as a function of stimulus or task duration. However, there is increasing evidence that regional brain responses may not always translate to task duration and rather show stimulus onset-related transient time courses. We assume that brain regions showing transient responses cannot be detected in…
Loss of interferon-gamma inducibility of the MHC class II antigen processing pathway in head and neck cancer: evidence for post-transcriptional as we…
2008
Summary Background Abnormalities of the major histocompatibility complex (MHC) antigens by tumour cells impair the cellular immune response and promote tumour evasion from immune surveillance. So far, studies analysing the MHC class II expression levels in head and neck cancer have been limited. Objectives Therefore, we investigated the constitutive and interferon (IFN)-γ-regulated expression profiles of MHC class II antigen processing machinery (APM) in various head and neck cancer cell lines and also analysed the MHC class II expression in head and neck cancer lesions. Methods Using immunohistochemistry, flow cytometry, and reverse transcriptase-polymerase chain reaction analyses we in…
Volume stability of hydroxyapatite and β-tricalcium phosphate biphasic bone graft material in maxillary sinus floor elevation: a radiographic study u…
2015
Objectives The purpose of this study was to confirm volume stability of biphasic calcium phosphate (BCP) through the changes of grafted volume over the time by 3D CT analyzing software program. Patients and Methods Fifteen patients, 16 sinuses who were scheduled a staged implantation through sinus floor elevation (SFE)–lateral window technique from 2009 to 2011 were included in the study. Of the 15 patients, eight were male and seven were female (mean age 50.1). For sinus floor augmentation, BCP with local blood was packed loosely into the maxillary sinus and the grafted site was covered with a collagen membrane. For the evaluation of volume change, 3D CBCT scans were taken five times at pr…
Facilitating cartilage volume measurement using MRI.
2010
To compare quantitative cartilage volume measurement (CVM) using different slice thicknesses.Ten knees were scanned with a 1.5T MRI (Sonata, Siemens, Erlangen, Germany) using a 3D gradient echo sequence (FLASH, fast low-angle shot). Cartilage volume of the medial and lateral tibial plateau was measured by two independent readers in 1.5mm, 3.0mm and 5.0mm slices using the Argus software application. Accuracy and time effectiveness served as control parameters.Determining cartilage volume, time for calculation diminished for the lateral tibial plateau from 384.6+/-127.7s and 379.1+/-117.6s to 214.9+/-109.9s and 213.9+/-102.2s to 122.1+/-60.1s and 126.8+/-56.2s and for the medial tibial platea…
Magnetic resonance chondro-crassometry (MR CCM): a method for accurate determination of articular cartilage thickness?
1996
A method for the assessment of articular cartilage thickness based on MRI is presented and its accuracy and reproducibility tested. Six specimens of human patellae were imaged, using a fat-suppressed FLASH 3D sequence, and sectioned with a high-precision band saw. The regional distribution of articular cartilage thickness was determined from the MR images and from the anatomical sections (intervals of 0.5 mm). With image analysis 50-90% of the image points were found to lie within exactly the same thickness interval in corresponding patterns, and less than 17% deviated more than 0.5 mm. More than 85% of all pixels were reproducible with MRI after new positioning of the joint. No influence o…
Repeatability of patellar cartilage thickness patterns in the living, using a fat-suppressed magnetic resonance imaging sequence with short acquisiti…
1998
A fast, reproducible, and noninvasive method is required for quantifying cartilage thickness clinically and for studying the deformation of articular cartilage during and after mechanical loading in vivo. The objective of the current investigation was to test the repeatability of regional distribution patterns of patellar cartilage thickness in the living on the basis of a fat-suppressed magnetic resonance imaging sequence with a short acquisition time and three-dimensional digital data processing. The knees of eight healthy volunteers were transversally imaged with a fat-suppressed FLASH-3D (fast low angle shot) sequence (acquisition time: 4 minutes and 10 seconds). In each case, the joint…
Non-invasive determination of cartilage thickness throughout joint surfaces using magnetic resonance imaging.
1997
Abstract Data on articular cartilage thickness in the living are important for the design of computer models, aimed at preoperatively assessing the effect of surgical procedures on joint contact and load transmission, and for the calculation of cartilage material properties from its deformational behavior as determined during arthroscopy. A non-invasive method for measuring cartilage thickness in living subjects is, however, not available. A technique based on magnetic resonance imaging has therefore been tested for assessing articular cartilage thickness throughout joint surfaces. The accuracy is determined by comparing cartilage thickness maps obtained from three patellar specimens with a…
Posttranslationally modified proteins as mediators of sustained intestinal inflammation.
2006
Oxidative and carbonyl stress leads to generation of N(epsilon)-carboxymethyllysine-modified proteins (CML-mps), which are known to bind the receptor for advanced glycation end products (RAGE) and induce nuclear factor (NF)-kappaB-dependent proinflammatory gene expression. To determine the impact of CML-mps in vivo, RAGE-dependent sustained NF-kappaB activation was studied in resection gut specimens from patients with inflammatory bowel disease. Inflamed gut biopsy tissue demonstrated a significant up-regulation of RAGE and increased NF-kappaB activation. Protein extracts from the inflamed zones, but not from noninflamed resection borders, caused perpetuated NF-kappaB activation in cultured…
The attentional blink demonstrates automatic deviance processing in vision.
2011
Rare deviations in serial visual stimulation are accompanied by an occipital N2 in the event-related potential [the visual mismatch negativity (vMMN)]. Recent research suggests that the vMMN reflects automatic processing of information on the sensory level as a basis for change detection. To directly test the hypothesis that the vMMN is independent from attention, a rapid-serial-visual-presentation paradigm was applied: Either 300 ms or 700 ms after the presentation of a target (T1) a rare position change was embedded in the stimulation which elicited a vMMN. In another condition participants had to detect a second target (T2) after T1: Importantly, within 300 ms after T1, T2 detection was …