Search results for " project"
showing 10 items of 1296 documents
Mediterranean diet and adiposity in children and adolescents: A systematic review
2021
Our aim was to summarize, through a systematic review, the current evidence from dietary intervention and observational studies on the impact of adherence to the Mediterranean diet on adiposity markers and obesity in children and adolescents. We searched Medline up to June 1, 2021 for the identification of intervention and observational studies meeting the inclusion criteria, following the PRISMA statement. We included 55 articles: 8 intervention studies and 47 observational studies. Three trials report a beneficial effect of the dietary intervention, whereas two did not, and three did not compare with a control. All observational studies were cross-sectional, and only five studies also inc…
Protein supplementation and dietary behaviours of resistance trained men and women attending commercial gyms: a comparative study between the city ce…
2014
Background: It is anecdotally recognized that commercial gym users assume supplements in order to improve performance or health. However, dietary behaviours of people and athletes attending commercial gyms have been poorly studied. The exact amount and frequency of dietary supplements consumption are still needed to be investigated. The main purpose of this study is to understand the quantity and quality of food intake, as well as dietary supplementation in people attending commercial gyms. Secondly to compare the city centre and the suburbs of Palermo, Italy. Methods: A face-to-face questionnaire was administered to 561 subjects, 207 from the city centre (CC) and 354 from the suburbs (SB) …
Operation and first results of the NEXT-DEMO prototype using a silicon photomultiplier tracking array
2013
NEXT-DEMO is a high-pressure xenon gas TPC which acts as a technological test-bed and demonstrator for the NEXT-100 neutrinoless double beta decay experiment. In its current configuration the apparatus fully implements the NEXT-100 design concept. This is an asymmetric TPC, with an energy plane made of photomultipliers and a tracking plane made of silicon photomultipliers (SiPM) coated with TPB. The detector in this new configuration has been used to reconstruct the characteristic signature of electrons in dense gas, demonstrating the ability to identify the MIP and "blob" regions. Moreover, the SiPM tracking plane allows for the definition of a large fiducial region in which an excellent e…
Efficacy of Selected Electrical Therapies on Chronic Low Back Pain: A Comparative Clinical Pilot Study
2017
Background: In the currently available research publications on electrical therapy of low back pain, generally no control groups or detailed randomization were used, and such studies were often conducted with relatively small groups of patients, based solely on subjective questionnaires and pain assessment scales (lacking measurement methods to objectify the therapeutic progress). The available literature also lacks a comprehensive and large-scale clinical study. The purpose of this study was to assess the effects of treating low back pain using selected electrotherapy methods. The study assesses the influence of individual electrotherapeutic treatments on reduction of pain, improvement of …
The upgrade of the ALICE TPC with GEMs and continuous readout
2020
Journal of Instrumentation 16(03), P03022 (2021). doi:10.1088/1748-0221/16/03/P03022
Dependence of polytetrafluoroethylene reflectance on thickness at visible and ultraviolet wavelengths in air
2020
[EN] Polytetrafluoroethylene (PTFE) is an excellent diffuse reflector widely used in light collection systems for particle physics experiments. However, the reflectance of PTFE is a function of its thickness. In this work, we investigate this dependence in air for light of wavelengths 260 nm and 450 nm using two complementary methods. We find that PTFE reflectance for thicknesses from 5 mm to 10 mm ranges from 92.5% to 94.5% at 450 nm, and from 90.0% to 92.0% at 260 nm We also see that the reflectance of PIFE of a given thickness can vary by as much as 2.7% within the same piece of material. Finally, we show that placing a specular reflector behind the PTFE can recover the loss of reflectan…
Absolute momentum calibration of the HARP TPC
2008
In the HARP experiment the large-angle spectrometer is using a cylindrical TPC as main tracking and particle identification detector. The momentum scale of reconstructed tracks in the TPC is the most important systematic error for the majority of kinematic bins used for the HARP measurements of the double-differential production cross-section of charged pions in proton interactions on nuclear targets at large angle. The HARP TPC operated with a number of hardware shortfalls and operational mistakes. Thus it was important to control and characterize its momentum calibration. While it was not possible to enter a direct particle beam into the sensitive volume of the TPC to calibrate the detect…
DARWIN: Towards the ultimate dark matter detector
2016
DARk matter WImp search with liquid xenoN (DARWIN) will be an experiment for the direct detection of dark matter using a multi-ton liquid xenon time projection chamber at its core. Its primary goal will be to explore the experimentally accessible parameter space for Weakly Interacting Massive Particles (WIMPs) in a wide mass-range, until neutrino interactions with the target become an irreducible background. The prompt scintillation light and the charge signals induced by particle interactions in the xenon will be observed by VUV sensitive, ultra-low background photosensors. Besides its excellent sensitivity to WIMPs above a mass of 5 GeV/c2, such a detector with its large mass, low-energy …
A 4 tonne demonstrator for large-scale dual-phase liquid argon time projection chambers
2018
A 10 kilo-tonne dual-phase liquid argon TPC is one of the detector options considered for the Deep Underground Neutrino Experiment (DUNE). The detector technology relies on amplification of the ionisation charge in ultra-pure argon vapour and offers several advantages compared to the traditional single-phase liquid argon TPCs. A 4.2 tonne dual-phase liquid argon TPC prototype, the largest of its kind, with an active volume of \three has been constructed and operated at CERN. In this paper we describe in detail the experimental setup and detector components as well as report on the operation experience. We also present the first results on the achieved charge amplification, prompt scintillat…
NEXT, high-pressure xenon gas experiments for ultimate sensitivity to Majorana neutrinos
2012
In this paper we describe an innovative type of Time Projection Chamber (TPC), which uses high-pressure xenon gas (HPXe) and electroluminescence amplification of the ionization charge as the basis of an apparatus capable of fully reconstructing the energy and topological signature of rare events. We will discuss a specific design of such HPXe TPC, the NEXT-100 detector, that will search for neutrinoless double beta decay events using 100-150 kg of xenon enriched in the isotope Xe-136. NEXT-100 is currently under construction, after completion of an accelerated and very successful R&D period. It will be installed at the Laboratorio Subterr��neo de Canfranc (LSC), in Spain. The commission…