Implant-supported metal-ceramic and resin-modified ceramic crowns: A 5-year prospective clinical study.

2018

Abstract Statement of problem Because of market demand for innovation, new restoration materials have been introduced without adequate testing; clinical failure may be the consequence, and clinical studies are needed. Purpose The purpose of this clinical study was to evaluate the biological and mechanical clinical behavior of implant-supported resin-modified ceramic crowns compared with that of metal-ceramic crowns. Material and methods Forty-two participants aged between 35 and 65 years received single implants in posterior edentulous sites. After the osseointegration period, half of the implants (selected randomly) (n=25) were restored with metal-ceramic crowns (MC group) and the other ha…

Ceramicsmedicine.medical_treatmentDentistryDental AbutmentsCrown (dentistry)Osseointegration03 medical and health sciences0302 clinical medicineDental porcelainstomatognathic systemDental AbutmentsmedicineCeramicDental Restoration FailureProspective StudiesSurvival rateDental ImplantsCrownsbusiness.industryDental prosthesis030206 dentistryDental PorcelainMetalsvisual_artvisual_art.visual_art_mediumImplantDental Prosthesis Implant-SupportedZirconiumOral SurgerybusinessThe Journal of prosthetic dentistry
researchProduct

The use of Endurant stent-graft for abdominal aortic aneurysm: the story about extension of instruction for use with persistent good results of stent…

2012

The Endurant stent-graft (Medtronic, Inc., Minneapolis, MN, USA) is a latest generation device for the treatment of abdominal aortic aneurysm. The idea behind designing such a graft came from the intention to broad the instruction for use (IFU) and to enable it to treat more challenging anatomy including the 10mm neck lengths, and more severe suprarenal and infrarenal angulations. Endurant stent-graft has active fixation through suprarenal stent with anchoring pins to provide migration resistance, optimized heights of stents and spacing between them for improved flexibility and conformability, low-profile delivery system with hydrophilic coating and controlled simple deployment mechanism. S…

Clinical Trials as TopicEvidence-Based Medicine10042 Clinic for Diagnostic and Interventional RadiologyEndovascular Procedures610 Medicine & healthProsthesis DesignRisk Assessment2705 Cardiology and Cardiovascular Medicine10020 Clinic for Cardiac Surgery2746 SurgeryBlood Vessel ProsthesisBlood Vessel Prosthesis ImplantationTreatment OutcomeRisk FactorsHumansStentsClinical CompetenceRegistriesLearning Curvestents endovascular procedures aortic aneurysm abdominalAortic Aneurysm Abdominal
researchProduct

Dorsal Column Nuclei Neural Signal Features Permit Robust Machine-Learning of Natural Tactile- and Proprioception-Dominated Stimuli

2020

Neural prostheses enable users to effect movement through a variety of actuators by translating brain signals into movement control signals. However, to achieve more natural limb movements from these devices, the restoration of somatosensory feedback is required. We used feature-learnability, a machine-learning approach, to assess signal features for their capacity to enhance decoding performance of neural signals evoked by natural tactile and proprioceptive somatosensory stimuli, recorded from the surface of the dorsal column nuclei (DCN) in urethane-anesthetized rats. The highest performing individual feature, spike amplitude, classified somatosensory DCN signals with 70% accuracy. The hi…

Computer scienceCognitive NeuroscienceNeuroscience (miscellaneous)Somatosensory systemSignalgracilelcsh:RC321-57103 medical and health sciencesCellular and Molecular Neuroscience0302 clinical medicineDevelopmental Neurosciencemedicinesupervised back-propagation artificial neural networklcsh:Neurosciences. Biological psychiatry. NeuropsychiatryOriginal Research030304 developmental biologyBrain–computer interfacecuneate0303 health sciencesProprioceptionNeural Prosthesisfeature learnabilitymedicine.anatomical_structureFeature (computer vision)Dorsal column nucleiNeuroscienceneural prosthesisbrain-machine interface030217 neurology & neurosurgeryNeuroscienceNeural decodingFrontiers in Systems Neuroscience
researchProduct

Biomechanical analysis of two types of osseointegrated transfemoral prosthesis

2020

In the last two decades, osseointegrated prostheses have been shown to be a good alternative for lower limb amputees experiencing complications in using a traditional socket-type prosthesis

Computer sciencemedicine.medical_treatmentFinite element analysi0206 medical engineeringOPLProsthetic limb02 engineering and technologyProsthesislcsh:TechnologyOsseointegrationlcsh:Chemistry03 medical and health sciencesDistal femur0302 clinical medicineosseointegrated prosthesismedicineGeneral Materials ScienceCADOPL osseointegrated prosthesiSettore ING-IND/15 - Disegno E Metodi Dell'Ingegneria IndustrialeInstrumentationlcsh:QH301-705.5Fluid Flow and Transfer ProcessesOrthodontics030222 orthopedicslcsh:TProcess Chemistry and TechnologyGeneral EngineeringFinite element analysisOPL osseointegrated prosthesisLimitingStress distributionTransfemoral amputeeequipment and supplies020601 biomedical engineeringTransfemoral prosthesislcsh:QC1-999OPRAComputer Science Applicationsbody regionslcsh:Biology (General)lcsh:QD1-999lcsh:TA1-2040Implantlcsh:Engineering (General). Civil engineering (General)lcsh:Physics
researchProduct

Prosthetically‐Driven Full‐Mouth Implant‐Supported Prostheses Using Guided Surgical Implant Planning with Composite Resin Markers: A Case Report

2021

This report describes a prosthetically-driven implant planning method, guided by the alignment procedures between the cone beam computed tomography, intraoral digital scans, and digitized maxillary and mandibular interim complete dentures using intraoral composite resin markers as a common reference. The markers were attached to the keratinized oral mucosa of the edentulous ridges using cyanoacrylate and kept in place during the digitizing procedures. The technique provides a simpler and more economical alternative to conventional prosthetically-driven static implant planning methods.

Cone beam computed tomographymedicine.medical_treatment0206 medical engineering02 engineering and technologyComposite Resinslaw.invention03 medical and health sciences0302 clinical medicinelawPlanning methodmedicineHumansGeneral DentistryDental ImplantsOrthodonticsMouthbusiness.industry030206 dentistry020601 biomedical engineeringSurgical implantCyanoacrylateComputer-Aided DesignDental Prosthesis Implant-SupportedImplantDenturesProsthodonticsbusinessImplant supportedJournal of Prosthodontics
researchProduct

2017

We propose a mesh-free and discrete (particle-based) multi-physics approach for modelling the hydrodynamics in flexible biological valves. In the first part of this study, the method is successfully validated against both traditional modelling techniques and experimental data. In the second part, it is further developed to account for the formation of solid aggregates in the flow and at the membrane surface. Simulations of various types of aggregates highlight the main benefits of discrete multi-physics and indicate the potential of this approach for coupling the hydrodynamics with phenomena such as clotting and calcification in biological valves.

CouplingMultidisciplinaryAggregate (data warehouse)Blood flow01 natural sciencesMesh free010305 fluids & plasmas010101 applied mathematicsFlow (mathematics)Blood vessel prosthesis0103 physical sciencesFluid dynamics0101 mathematicsMembrane surfaceBiological systemPLOS ONE
researchProduct

Peri-implant parameters in head and neck reconstruction: influence of extraoral skin or intraoral mucosa.

2009

Objective: This study is designed to assess dental implants supporting overdentures in edentulous patients with operated head and neck malignancies using parameters to detect peri-implant disease. Material and methods: Thirty-four implants supporting overdentures in 34 oral cancer patients were examined. Clinical parameters [plaque index, probing depth, bleeding on probing (BOP), origin of peri-implant soft tissue, and amount of irradiation] were recorded, and microbiological identification of periodontal pathogens was carried out by DNA–DNA hybridization. To identify yeast species, the samples were cultivated on Sabouraud agar plates and subsequently identified by API 20C AUX plates. An im…

DNA BacterialMaleRadiographyBleeding on probingDentistryPilot ProjectsSabouraud agarPeriodontal pathogenchemistry.chemical_compoundmedicineHumansDNA FungalAgedCandidaDental ImplantsUnivariate analysisAnalysis of VarianceChi-Square Distributionbusiness.industryDental prosthesisDental Implantation EndosseousMouth MucosaSoft tissueSkin TransplantationDenture OverlaychemistryHead and Neck NeoplasmsFemaleImplantDental Prosthesis Implant-SupportedOral Surgerymedicine.symptomCranial IrradiationbusinessClinical oral implants research
researchProduct

Narrow-diameter implants: A systematic review and meta-analysis.

2018

OBJECTIVES Narrow-diameter implants (NDI) are claimed to be a reasonable alternative to bone augmentation procedures. The aim of this comprehensive literature review was to conduct a meta-analysis comparing the implant survival of NDI and standard diameter implants (SDI) and to provide recommendations and guidelines for application of NDI. MATERIAL AND METHODS An extensive systematic literature search was performed in the PubMed/MEDLINE and the Cochrane Library databases. NDI were classified into Category 1 (implant diameter <3.0 mm, "mini-implants"), Category 2 (implant diameter 3-3.25 mm) and Category 3 (implant diameters 3.3-3.5 mm). Clinical studies at all levels of evidence with at lea…

Databases Factualmedicine.medical_treatmentMEDLINEAlveolar Bone LossDentistryMandibleCochrane LibraryBone augmentation03 medical and health sciences0302 clinical medicineAtrophic maxillamedicineMaxillaHumansDental Restoration FailureDental ImplantsRehabilitationbusiness.industryDental Implantation EndosseousInterdental consonant030206 dentistryAlveolar Ridge AugmentationSurvival AnalysisDental Prosthesis Design030220 oncology & carcinogenesisMeta-analysisImplantOral SurgerybusinessClinical oral implants research
researchProduct

Treatment concepts of horizontally deficient ridges-A retrospective study comparing narrow-diameter implants in pristine bone with standard-diameter …

2021

OBJECTIVES To compare clinical and radiological outcomes of narrow-diameter implants (NDI) placed in pristine bone to standard-diameter implants placed in combination with horizontal bone augmentation procedures (SDI+A) for horizontally deficient alveolar ridges. MATERIAL AND METHODS For this retrospective study, the outcome of 597 NDI (∅ 3.3 mm, 272 patients), inserted in pristine bone, were compared with 180 SDI (∅ 4.1 mm, 83 patients), inserted in combination with horizontal augmentation procedures. Oral health-related quality of life was assessed in patients available for recall. RESULTS After a mean follow-up of 37.6 ± 40 months for the NDI and of 42.4 ± 49 months for the SDI+A, surviv…

Dental ImplantsAugmentation procedurebusiness.industrySignificant differenceDental Implantation EndosseousDentistryRetrospective cohort studyBone augmentationPatient satisfactionDental Prosthesis DesignQuality of LifeMedicineHumansIn patientImplantOral SurgerybusinessRetrospective StudiesClinical oral implants researchREFERENCES
researchProduct

Effects of minute misregistrations of prefabricated markers for image-guided dental implant surgery: an analytical evaluation

2012

Objectives The goal of the present study was to develop a theoretical analysis of errors in implant position, which can occur owing to minute registration errors of a reference marker in a cone beam computed tomography volume when inserting an implant with a surgical stent. Material and methods A virtual dental-arch model was created using anatomic data derived from the literature. Basic trigonometry was used to compute effects of defined minute registration errors of only voxel size. The errors occurring at the implant's neck and apex both in horizontal as in vertical direction were computed for mean ±95%-confidence intervals of jaw width and length and typical implant lengths (8, 10 and 1…

Dental ImplantsCone beam computed tomographymedicine.medical_specialtyComputer scienceDental Implantation EndosseousCone-Beam Computed Tomographycomputer.software_genreModels DentalPatient Care PlanningSurgeryDental implant surgeryImaging Three-DimensionalDental Prosthesis DesignSurgery Computer-AssistedVoxelPosition (vector)Vertical directionRange (statistics)medicineHumansImplantOral SurgeryFrontal regioncomputerBiomedical engineeringClinical Oral Implants Research
researchProduct