A multicenter 12-month experience with a new iliac side-branched device for revascularization of hypogastric arteries.
2016
Abstract Objective The aim of this study was to investigate the 1-year safety and efficacy of a new iliac side-branched device (IBD) for revascularization of the hypogastric arteries. Methods Patients receiving the E-liac (Jotec GmbH, Hechingen, Germany) side-branched device at six German vascular centers either as a stand-alone procedure or in combination with abdominal aortic aneurysm exclusion were included in a prospectively created data bank. Collected data were analyzed for baseline characteristics, procedural events, and clinical follow-up; variables included endoleaks, reinterventions, and internal iliac artery (IIA) patency. Results Between January 2012 and January 2015, a total of…
A 15-Year Single-Center Experience of Endovascular Repair for Elective and Ruptured Abdominal Aortic Aneurysms
2016
Purpose: To evaluate the differences in technical outcomes and secondary interventions between elective endovascular aneurysm repair (el-EVAR) procedures and those for ruptured aneurysms (r-EVAR). Methods: Of the 906 patients treated with primary EVAR from September 1998 until July 2012, 43 cases were excluded owing to the use of first-generation stent-grafts. Among the remaining 863 patients, 773 (89.6%) patients (mean age 72 years; 697 men) with asymptomatic or symptomatic abdominal aortic aneurysms (AAAs) were assigned to the el-EVAR group; 90 (10.4%) patients (mean age 73 years; 73 men) were assigned to the r-EVAR group based on blood outside the aortic wall on preoperative imaging. Th…
Long-term results of simplified frozen elephant trunk technique in complicated acute type A aortic dissection: A case-control study.
2016
Aim To describe the long-term experience of a simplified frozen elephant trunk technique (sFETT) used in complicated acute type A aortic dissection (AAAD) treatment. Methods and results Between January 2001 and December 2012, 34 patients (mean age 59.9 ± 11.0 years) with complicated AAAD (DeBakey I) underwent an emergency surgery including sFETT. sFETT consisted in gluing the dissected aortic arch wall layers with gelatine-resorcinol adhesive and video-assisted antegrade open arch aortic stent-graft deployment in the arch or proximal descending aorta. In addition to sFETT, the aortic root was addressed with standard techniques. A 30-day mortality was 14.7% (five patients) due to bleeding (1…
Mid-term Results of Chimney and Periscope Grafts in Supra-aortic Branches in High Risk Patients
2017
Purpose Report mid-term outcomes of thoracic endovascular aneurysm repair (TEVAR) with chimney and periscope grafts (CPG) in supra-aortic branches (SAB). Methods Retrospective analysis, from October 2009 to May 2014, of patients with aneurysms requiring TEVAR with zone 0/1/2 proximal landing in association with at least one CPG in the SAB. All patients were considered at high risk for conventional surgery. Peri-operative mortality and morbidity, retrograde type A dissection, maximum aortic transverse diameter (TD) and its post-operative evolution, endoleak, survival, freedom from cardiovascular re-interventions, and CPG freedom from occlusion during the follow-up were analysed. Results Fort…
Hybrid Endograft Solution for Complex Iliac Anatomy
2010
The purpose of this study was to evaluate single-center results with selective use of Gore Excluder limbs (W.L. Gore & Associates, Flagstaff, AZ) in a Cook Zenith body (Cook Inc, Bloomington, IN) for elective endovascular abdominal aortic aneurysm (AAA) repair. A prospectively held database for patients with AAA, who were treated endovascularly between March 1999 and July 2008, was queried for patients treated with a Cook Zenith body and one or two Gore Excluder limbs. Indication, technical success, late limb occlusion, and disconnection were evaluated. From 276 patients who were treated with a Zenith body, 29 underwent repair with hybrid graft components with, in total, 41 Gore Exclud…
Influence of occlusal loading on peri-implant clinical parameters. A pilot study
2013
Objectives: To investigate the relation between occlusal loading and peri-implant clinical parameters (probing depth, bleeding on probing, gingival retraction, width of keratinized mucosa, and crevicular fluid volume) in pa - tients with implant-supported complete fixed prostheses in both arches. Material and Methods: This clinical study took place at the University of Valencia (Spain) dental clinic. It included patients attending the clinic for regular check-ups during at least 12 months after rehabilitation of both arches with implant-supported complete fixed ceramo-metallic prostheses. One study implant and one control implant were established for each patient using the T-Scan®III comput…
Straight and tilted implants for supporting screw-retained full-arch dental prostheses in atrophic maxillae : a 2-year prospective study
2018
Background To evaluate, over a 2-year period, the treatment outcomes for maxillary full-arch fixed dental prostheses (FDPs) supported by a combination of both tilted and axially-placed implants and to compare the marginal bone loss (MBL) and implant survival rates (SR) between tilted and axial implants. Material and Methods A retrospective study has been carried out. Thirty-two patients (16 males and 16 females) treated with maxillary full-arch FDPs were included in this retrospective study. A total of 187 implants were inserted to rehabilitate the fully edentulous maxillary arches: 36% of them were tilted (T group, n = 68) and the remaining 64% were axially placed (A group, n = 119). From …
Peroperative Intravascular Ultrasound for Endovascular Aneurysm Repair versus Peroperative Angiography: A Pilot Study in Fit Patients with Favorable …
2020
The aim of this study was to compare intravascular ultrasound (IVUS) assistance for endovascular aortic aneurysm repair (EVAR) to standard assistance by angiography.From June 2015 to June 2017, 173 consecutive patients underwent EVAR. In this group, 69 procedures were IVUS-assisted with X-ray exposure limited to completion angiography for safety purposes because an IVUS probe does not yet incorporate a duplex probe (group A), and 104 were angiography-assisted procedures (group B). All IVUS-assisted procedures were performed by vascular surgeons with basic duplex ultrasound (DUS) training. The primary study endpoints were mean radiation dose, duration of fluoroscopy, amount of contrast media…
Anastomotic Pseudoaneurysm Complicating Renal Transplantation: Treatment Options
2010
Introduction: Anastomotic pseudoaneurysm following renal transplantation is uncommon. Indications for repair, treatment options and outcomes remain controversial. Report: We present 6 renal transplant recipients with large anastomotic pseudoaneurysms. Five of the patients underwent open repair while one had a stent-grafting and delayed transplant nephrectomy for a ruptured pseudoaneurysm. A transplant nephrectomy was needed in all cases but one. Arterial reconstruction enabled limb salvage in all cases. One patient died of sepsis postoperatively. No patient presented late infection, failure of vascular reconstruction, nor pseudoaneurysm recurrence. Conclusions: Surgical excision of anastomo…
Time interval between infective endocarditis first symptoms and diagnosis: relationship to infective endocarditis characteristics, microorganisms and…
2016
International audience; OBJECTIVE: To analyze the characteristics and outcome of infective endocarditis (IE) according to the time interval between IE first symptoms and diagnosis.METHODS: Among the IE cases of a French population-based epidemiological survey, patients having early-diagnosed IE (diagnosis of IE within 1 month of first symptoms) were compared with those having late-diagnosed IE (diagnosis of IE more than 1 month after first symptoms).RESULTS: Among the 486 definite-IE, 124 (25%) had late-diagnosed IE whereas others had early-diagnosed IE. Early-diagnosed IE were independently associated with female gender (OR = 1.8; 95% CI [1.0-3.0]), prosthetic valve (OR= 2.6; 95% CI [1.4-5…