Search results for " prosthesis"

showing 10 items of 441 documents

Predictability of the resonance frequency analysis in the survival of dental implants placed in the anterior non-atrophied edentulous mandible.

2010

Background: Dental primary implant stability is considered essential in the success of the osseointegration process. The recent advent of the resonance frequency analysis (RFA) seems to effectively measure primary implant stability, although its relationship with implant survival has to be further established. Patients and Methods: Seventy patients with complete mandibular edentulism underwent dental implant rehabilitation by means of the placement of 68 dental implants within the interforaminal region and subsequent placement of an overdenture. Primary implant stability was measured by means of RFA and it was expressed in terms of imPrimary implant stability was measured by means of RFA an…

Malemedicine.medical_treatmentDentistryOsseointegrationDental Prosthesis RetentionHumansMedicineDental implantGeneral DentistrySurvival rateOrthodonticsEdentulismbusiness.industryDental Implantation EndosseousEdentulous mandibleMiddle AgedImplant stability quotientmedicine.disease:CIENCIAS MÉDICAS [UNESCO]Resonance frequency analysisOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASFemaleSurgeryImplantMouth Edentulousbusiness
researchProduct

A comparison of three different attachment systems for mandibular two-implant overdentures: one-year report.

2009

Background: There is a lack of clinical studies on the self-aligning attachment system (Locator®; Zest Anchors, Inc. homepage, Escondido, CA, USA) for two-implant-retained overdentures in the edentulous mandible. Therefore, a comparison of the Locator with two traditional designs (a rotational gold matrix and a rubber O-ring type) in clinical 1-year use was conducted. MaterialsandMethods: From 2003 to 2007, 60 patients received two Osseotite® TG Standard implants (BIOMET 3i Implant Innovations, Palm Beach Gardens, FL, USA) in the intraforaminal area of the edentulous mandible. The implants were left unloaded for 3.5 months, randomized to three different attachment systems, and loaded throug…

Malemedicine.medical_treatmentDenture Complete LowerDentistryDental AbutmentsOral HealthMandiblelaw.inventionDental AbutmentsRandomized controlled triallawmedicineDenture Precision AttachmentHumansJaw EdentulousProspective StudiesDental implantProspective cohort studyDenture DesignGeneral DentistryDenture RetentionAgedOrthodonticsAged 80 and overDental Implantsbusiness.industryDental prosthesisDental Implantation EndosseousMiddle AgedDenture OverlayDenture RetentionTreatment OutcomeDenture DesignQuality of LifeFemaleImplantDental Prosthesis Implant-SupportedOral SurgerybusinessClinical implant dentistry and related research
researchProduct

Patient-centered and clinical outcomes of mandibular overdentures retained with the locator system: A prospective observational study

2017

Whether clinical or demographic variables affect the perception of treatment in terms of quality of life and satisfaction is unknown.The purpose of this prospective study was to make an evidence-based assessment of the treatment outcomes (patient- and clinically based) of locator-retained mandibular overdentures.This prospective observational study assessed patients with edentulism who had worn mandibular overdentures supported by 2 implants and retained by the locator system for at least 1 year of functional life (N=80). Medical histories were reviewed, and patients underwent oral examinations. Prosthetic clinical outcomes and patient well-being were registered using the Oral Health Impact…

Malemedicine.medical_treatmentDenture Complete LowerDentistryOral HealthMandibleAffect (psychology)Prosthesis03 medical and health sciences0302 clinical medicinePatient satisfactionQuality of lifeSurveys and QuestionnairesDenture RebasingHumansJaw EdentulousMedicineProspective StudiesDenture DesignProspective cohort studySurvival analysisAgedDental ImplantsEdentulismbusiness.industry030206 dentistryDenture Overlaymedicine.diseaseDenture RetentionSurvival Analysisstomatognathic diseasesTreatment OutcomePatient SatisfactionSpainQuality of LifeFemaleObservational studyDental Prosthesis Implant-SupportedOral Surgerybusiness030217 neurology & neurosurgeryFollow-Up StudiesThe Journal of Prosthetic Dentistry
researchProduct

Haemodynamic predictors of a penetrating atherosclerotic ulcer rupture using fluid-structure interaction analysis

2013

We present preliminary data on the flow-induced haemodynamic and structural loads exerted on a penetrating atherosclerotic aortic ulcer (PAU). Specifically, one-way fluid-structure interaction analysis was performed on the aortic model reconstructed from a 66-year-old male patient with a PAU that evolved into an intramural haematoma and rupture of the thoracic aorta. The results show that elevated blood pressure (117 mmHg) and low flow velocity at the aortic wall (0.15 m/s(2)) occurred in the region of the PAU. We also found a low value of time-averaged wall shear stress (1.24 N/m(2)) and a high value of the temporal oscillation in the wall shear stress (oscillatory shear index = 0.13) in t…

Malemedicine.medical_treatmentHemodynamicsAorta ThoracicMedicineThoracic aortaHematomamedicine.diagnostic_testEndovascular ProceduresModels CardiovascularSettore ING-IND/34 - Bioingegneria IndustrialeAnatomyTreatment OutcomeAtherosclerosiCardiologyWall shear streCardiology and Cardiovascular MedicineBrief CommunicationsBlood Flow VelocityHumanPulmonary and Respiratory Medicinemedicine.medical_specialtyAortographyAortic RuptureAortic DiseasesAortographyBlood Vessel Prosthesis ImplantationSettore ING-IND/14 - Progettazione Meccanica E Costruzione Di MacchinePenetrating atherosclerotic ulcerPenetrating atherosclerotic ulcerInternal medicinemedicine.arteryFluid-structure interactionShear stressHumansArterial PressureComputer SimulationHemodynamicAortic ruptureUlcerAgedEndovascular Procedurebusiness.industryHemodynamicsStentmedicine.diseaseAtherosclerosisAortic DiseaseBlood pressureRegional Blood FlowSurgeryStress MechanicalbusinessTomography X-Ray Computed
researchProduct

Oral health-related quality of life of implant-supported overdentures versus conventional complete prostheses: Retrospective study of a cohort of ede…

2015

Background This work aims to confirm if implant-supported overdentures are a good treatment option for edentulous patients and offer an improvement in quality of life compared with traditional complete prostheses (dentures). Material and Methods This retrospective clinical descriptive study included three evaluation groups: validation group (n=57); control group of patients with complete removeable prostheses (n=56); study group of patients with implant-supported overdentures retained with the Locator® system (n=80). The study also validated the Oral Health Impact Profile-20 questionnaire. Individual protocols were created that included socio-demographic data, the Oral Health Impact Profile…

Malemedicine.medical_treatmentPopulationDentistryOdontologíaOral HealthOral healthmedicineHumansJaw EdentulousStatistical analysiseducationGeneral DentistryAgedRetrospective Studieseducation.field_of_studyDenture Completebusiness.industryResearchRetrospective cohort study:CIENCIAS MÉDICAS [UNESCO]Medically compromised patients in DentistryDenture OverlayCiencias de la saludLinear relationshipOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASCohortQuality of LifeSurgeryFemaleDental Prosthesis Implant-SupportedDenturesbusinessImplant supportedMedicina Oral, Patología Oral y Cirugía Bucal
researchProduct

CEMENTLESS ACETABULAR RECONSTRUCTION AND STRUCTURAL BONE-GRAFTING IN DYSPLASTIC HIPS

2006

BACKGROUND: Studies of acetabular reconstruction with use of cement and bulk bone graft have demonstrated increasing rates of cup failure in patients with dysplastic hips seven years after total hip arthroplasty. Comparable data on the long-term results of bulk bone-grafting done in conjunction with cementless implants are limited. The aim of this study was to review the clinical and radiographic results of autologous bulk bone-grafting in conjunction with a cementless cup. METHODS: From 1987 to 1992, forty-seven patients (forty women and seven men, with an average age of 50.4 years) who had developmental dysplasia of the hip underwent fifty-six total hip arthroplasties and received a struc…

Malemusculoskeletal diseasesmedicine.medical_specialtyRadiographymedicine.medical_treatmentBone graftingHumansMedicineOrthopedic ProceduresOrthopedics and Sports MedicineProspective StudiesSurvival rateBone TransplantationHipbusiness.industryAcetabular reconstructionAcetabulumGeneral MedicineMiddle AgedAcetabulumSurgerysurgical procedures operativemedicine.anatomical_structureHip boneOrthopedic surgeryFemaleSurgeryHip ProsthesisImplantbusinessThe Journal of Bone and Joint Surgery-American Volume
researchProduct

Secondary Osseous Integration of Cementless Unicompartmental Knee Arthroplasty After Internal Fixation of a Felix Type IIIB Fracture

2021

Case A 76-year-old man presented with periprosthetic tibial plateau fracture (TPF), with a completely loosened tibial component 3 weeks after cementless unicompartmental knee arthroplasty (UKA). Internal fixation by buttress plating was performed, and the tibial component was retained and left in situ primarily as a spacer. Revision was planned after fracture consolidation, but at 3 months, the patient was able to walk without support, without pain, and with full range of motion. At 1 year, he is free of complaints. The initial loosened tibial component reintegrated. Conclusion Internal fixation combined with preserving the loosened tibial component may be a treatment option for TPF involvi…

Malemusculoskeletal diseasesmedicine.medical_specialtymedicine.medical_treatmentPeriprostheticFracture Fixation Internal03 medical and health sciences0302 clinical medicinemedicineTibial plateau fractureHumansInternal fixationOrthopedics and Sports Medicine030212 general & internal medicineFemoral componentArthroplasty Replacement KneeUnicompartmental knee arthroplastyAged030222 orthopedicsTibiabusiness.industryType iiibTreatment optionsequipment and suppliesmusculoskeletal systemmedicine.diseaseSurgeryTibial Fracturessurgical procedures operativeSurgeryKnee ProsthesisRange of motionbusinessJBJS Case Connector
researchProduct

Effect of alloy type and casting technique on the fracture strength of implant-cemented structures.

2010

Objectives: To evaluate the influence of alloy type and casting procedure on the fracture strength (FS) of metallic frameworks for implant-supported fixed prostheses. Study design: Thirty three-unit structures for lower posterior bridges were waxed-up and randomly assigned to two groups (n=15) according to alloy type and casting technique: Group 1 (C): cobalt-chromium cast in a centrifugal machine (TS1, Degussa-Hüls); Group 2 (T): titanium cast in a pressure-differential device (Cyclarc II, Morita). Each structure was cemented onto two prefabricated abutments under a constant seating pressure. After 6 months of water aging, samples were loaded in a static universal testing machine (EFH/5/FR…

Materials scienceAlloychemistry.chemical_elementDental Cementsengineering.materialWater agingFlexural strengthMaterials TestingAlloysHardness TestsComposite materialGeneral DentistryUniversal testing machineDental Casting Technique:CIENCIAS MÉDICAS [UNESCO]OtorhinolaryngologychemistryCasting (metalworking)UNESCO::CIENCIAS MÉDICASengineeringFracture (geology)Microscopy Electron ScanningSurgeryImplantDental Prosthesis Implant-SupportedTitaniumMedicina oral, patologia oral y cirugia bucal
researchProduct

Osseointegration of one-piece zirconia implants compared with a titanium implant of identical design: a histomorphometric study in the dog

2010

Objective: The aim of this study was to evaluate osseointegration of one-piece zirconia vs. titanium implants depending on their insertion depth by histomorphometry. Material and methods: Four one-piece implants of identical geometry were inserted on each side of six mongrel dogs: (1) an uncoated zirconia implant, (2) a zirconia implant coated with a calcium-liberating titanium oxide coating, (3) a titanium implant and (4) an experimental implant made of a synthetic material (polyetheretherketone). In a split-mouth manner they were inserted in submerged and non-submerged gingival healing modes. After 4 months, dissected blocks were stained with toluidine blue in order to histologically asse…

Materials scienceAlveolar Bone Losschemistry.chemical_elementDentistryInsertion depthOsseointegrationDogsCoated Materials BiocompatibleImplants ExperimentalOsseointegrationAnimalsCubic zirconiaDental ImplantsTitaniumMaterial typebusiness.industryDental Implantation EndosseousTitanium oxideDental Prosthesis DesignchemistryZirconiumImplantOral SurgerybusinessTitaniumA titaniumClinical Oral Implants Research
researchProduct

ePTFE ‐based biomedical devices: An overview of surgical efficiency

2021

International audience; Polytetrafluoroethylene (PTFE) is a ubiquitous material used for implants and medical devices in general because of its high biocompatibility and inertness: blood vessel, heart, table jawbone, nose, eyes, or abdominal wall can benefit from its properties in case of disease or injury. Its expanded version, ePTFE is an improved version of PTFE with better mechanical properties, which extends its medical applications. A material as frequently used as ePTFE with these exceptional properties deserves a review of its main uses, developments, and possibility of improvements. In this systematic review, we examined clinical trials related to ePTFE-based medical devices from t…

Materials scienceBiocompatibilityimplantmedicine.medical_treatmentmembrane barrierBiomedical EngineeringBypass grafts030204 cardiovascular system & hematologyBiomaterials03 medical and health scienceschemistry.chemical_compound0302 clinical medicineRenal DialysismedicineGuided bone and tissue regeneration[SPI.NANO]Engineering Sciences [physics]/Micro and nanotechnologies/MicroelectronicsePTFEPolytetrafluoroethyleneclinical trialsPolytetrafluoroethylenevascular graftStent030206 dentistryBlood Vessel Prosthesis3. Good health[SDV.MP]Life Sciences [q-bio]/Microbiology and ParasitologychemistryStentsstentHeart repairImplantVascular graftBiomedical engineering
researchProduct