Search results for " resin"
showing 10 items of 268 documents
Current dental adhesives systems. A narrative review.
2012
Adhesive dentistry is based on the development of materials which establish an effective bond with the tooth tissues. In this context, adhesive systems have attracted considerable research interest in recent years. Successful adhesive bonding depends on the chemistry of the adhesive, on appropriate clinical handling of the material as well as on the knowledge of the morphological changes caused on dental tissue by different bonding procedures. This paper outlines the status of contemporary adhesive systems, with particular emphasis on chemical characteristics and mode of interaction of the adhesives with enamel and dentinal tissues. Dental adhesives are used for several clinical application…
A comparative assessment of acceptance of different types of functional appliances
1998
Patients' acceptance of an orthodontic appliance may influence compliance and thus contribute to a successful outcome of treatment. The aim of this study was to assess the influence of shape and design of different types of functional appliances on their acceptance by patients. For each of 10 adult volunteer subjects employed in the study eight different functional appliances were fabricated which had a varying extension of the resin base and amount of interocclusal opening. Effects of appliances on speech, initial acceptance, and acceptance after wearing were assessed by means of standardized tests. Amongst the appliances tested the bionator, functional corrector FR-I and elastic open acti…
Accuracy of check-bite registration and centric condylar position
2002
In a dentate subject a jaw relation can either be determined in maximum intercuspation and is as such given by the occlusal morphology, or the mandibular position can be allocated according to the centric position of the condyles. For comprehensive restorative treatment or analytic measures of the occlusion it is important to record the centric condylar position. Various registration methods have been described in the literature, but there is no consensus on which is the 'best'. The aim of the present study was therefore to assess the accuracy of various registration methods and evaluate a possible influence of the used materials. Four dentists were involved in the clinical part of the stud…
Interruption of the enterohepatic circulation of phenprocoumon by cholestyramine
1977
The effect of cholestyramine (12 gm/day divided into 3 doses) on the pharmacokinetics and pharmacodynamics of a single intravenouse dose (30 mg) of phenprocoumon was studied in 6 normal subjects. Cholestyramine treatment led to an increase in the rate of elimination of phenprocoumon in all. Total clearance increased 1.5- to 2-fold. The total anticoagulant effect per dose was considerably reduced during treatment with cholestyramine. Binding studies in vitro showed that phenprocoumon is strongly bound to cholestyramine and that at a given cholestyramine concentration the percentage of phenprocoumon bound remained constant over a large concentration range of phenprocoumon. The results suggest…
Two-year clinical performance of a packable posterior composite with and without a flowable composite liner
2003
The aim of the study was to evaluate the clinical performance of a packable fine hybrid dental composite (Prodigy Condensable) and the influence of the additional application of a flowable resin composite (Revolution, SDS Kerr) layer on marginal integrity after 2 years in stress-bearing posterior cavities according to the Ryge criteria. In 50 patients (40.5+/-17.5 years of age), 116 class II fillings (metal matrix system, glass ionomer-cement-base in 36%, rubberdam isolation in 70%) were placed, with at least two restorations per patient. The adhesive Optibond Solo Plus was used for all the restorations. In one of the two fillings in each patient, an additional layer of the flowable composi…
Three-year clinical performance of two indirect composite inlays compared to direct composite restorations
2013
Objective: Despite the incremental build-up of resin composite restorations, their polymerization shrinkage during curing presents a serious problem. Indirect composite resin systems represent an alternative in overcoming some of the deficiencies of direct composite restorations. The hypothesis of the present study states that the clinical performance of restorations may be affected by different generation and application techniques. Study Design: Sixty restorations (20 DI system (Coltene/Whaledent AG, Altstatten, Switzerland) composite inlays, 20 Tescera ATL system (BISCO Inc. Schaumburg, Illinois, USA) composite inlays, and 20 direct composites) were applied to premolar teeth in 49 patien…
Long-term follow-up of a multifocal apodized diffractive intraocular lens after cataract surgery.
2007
Purpose To report the long-term performance of the AcrySof ReSTOR SA60D3 intraocular lens (IOL) after cataract surgery. Setting University Hospital Maastricht, Maastricht, The Netherlands. Methods This prospective clinical trial comprised 44 eyes (22 consecutive patients) having cataract surgery with implantation of the ReSTOR IOL. Monocular and binocular uncorrected distance visual acuity, best corrected distance visual acuity, uncorrected near visual acuity, best distance-corrected near visual acuity, spectacle dependence, undesired visual symptoms, patient satisfaction, and incidence of posterior capsule opacification were analyzed 6 months and 3 years postoperatively. Results The mean u…
In Vitro Percutaneous Penetration of Acyclovir from Solvent Systems and Carbopol 971-P Hydrogels: Influence of Propylene Glycol
2005
The mechanism underlying propylene glycol (PG) effects on acyclovir (ACV) penetration through human epidermis were studied. Solvent systems and Carbopol gels containing increasing percentage of PG (from 0% to 70%, w/w) were used. Viscosity studies of both vehicles were carried out to characterise the influence of rheological behaviour. In solvent systems skin permeation values of ACV increase as the concentration of PG increase yielding a maximum enhancement ratio (ER = 10) for 70% PG. The release rate of ACV from gels was determined. Higuchi's model was used to estimate the apparent diffusion coefficient of the drug. These values show a decrease as the content of PG in the vehicle increase…
Polyacrylonitrile block copolymers for the preparation of a thin carbon coating around TiO2 nanorods for advanced lithium-ion batteries.
2013
Herein, a new method for the realization of a thin and homogenous carbonaceous particle coating, made by carbonizing RAFT polymerization derived block copolymers anchored on anatase TiO2 nanorods, is presented. These block copolymers consist of a short anchor block (based on dopamine) and a long, easily graphitizable block of polyacrylonitrile. The grafting of such block copolymers to TiO2 nanorods creates a polymer shell, which can be visualized by atomic force microscopy (AFM). Thermal treatment at 700 °C converts the polyacrylonitrile block to partially graphitic structures (as determined by Raman spectroscopy), establishing a thin carbon coating (as determined by transmission electron m…
N-Propyl-N′-2-pyridylurea-modified silica as mixed-mode stationary phase with moderate weak anion exchange capacity and pH-dependent surface charge r…
2018
Herein, we present a novel silica-based stationary phase modified with N-propyl-N'-2-pyridylurea selector. Due to the weakly basic properties of the pyridine selector and the presence of residual silanols after selector immobilization, a zwitterionic surface with a pI observed at approximately pH 5.5 was measured by electrophoretic light scattering in pH-dependent ζ-potential determinations. The capability of the new N-propyl-N'-2-pyridylurea-modified silica to serve as mixed-mode stationary phase was investigated. For this purpose, it was characterized under RP and HILIC conditions using test mixtures. Subsequent classification of this stationary phase in comparison to in-house and commerc…