Search results for " resin"
showing 10 items of 268 documents
Minimal exposure time of different LED-curing devices
2007
Abstract Objectives The purpose of the study was to investigate the shortest possible exposure time of different LED-curing devices for five different resin composites in a clinically relevant in vitro-model, where a 7 mm distance from the light guide tip to the bottom side of the cavity was compiled. Methods Resin composite samples (Tetric EvoCeram A3, Filtek Supreme XT A3B, Premise A3, CeramX Mono M5, QuiXfil) were filled in three increments of 2 mm thickness each in stainless steel moulds (O = 5 mm, h = 6 mm, n = 9). The samples were incrementally exposed to different blue LED-curing devices (Bluephase, Bluephase C8, Bluephase 16i/Ivoclar Vivadent, L.E.Demetron II/sds Kerr, Elipar Free…
A tooth whitening and chemical abrasive protocol for the treatment of developmental enamel defects
2018
Abstract This clinical report describes a chemical abrasive protocol and whitening techniques to quantify modifications to the color and volume produced when eliminating white spots associated with developmental defects in enamel. Chemical (oxidative-erosive) abrasive treatment (whitening + 6.6% hydrochloric acid) resolves white spots up to a depth of 0.2 mm. At greater depths, infiltration with 16% hydrochloric acid followed by composite resin infiltration is recommended.
Photoelastic stress analysis assisted evaluation of fracture toughness in hydrothermally aged epoxies
2014
The present work has investigated the fracture toughness of a model DGEBA epoxy system subject to Hidro-Thermal aging. A Photoelastic Stress Analysis technique has been implemented, showing the evolution of stresses arising throughout the water uptake process due to the non-uniform swelling of the material. Gravimetric and Dynamic Mechanical Thermal Analyses have further complemented the characterization, showing the onset of plasticization effects with aging. The correlation of all previous characterizations has allowed to conclude that an increase of KIC fracture toughness is obtained at the fully saturated condition. In particular Photoelasticity has also revealed the onset of relevant s…
Phytochemical and anti-staphylococcal biofilm assessment of Dracaena draco L. Spp. draco resin
2013
Background: Dracaena draco L. ssp. draco is known as the “dragon's blood tree” and it is endemic from the Canary Islands and Morocco. Objective: Carry out phytochemical investigation of acetonic extracts of red resin obtained from the trunk of D. draco, to obtain to the isolation of the most abundant resin constituents, belonging to the class of flavonoids: flavans, along with homoisoflavans and homoisoflavanones. Materials and Methods: The structures of the isolated compounds were established by Nuclear Magnetic Resonance (NMR) and mass spectrometry data and comparison with literature data. The acetonic extract was evaluated for its anti-staphylococcal properties against two reference stra…
Multilayer capsules: a promising microencapsulation system for transplantation of pancreatic islets
2001
In 1980, Lim and Sun introduced a microcapsule coated with an alginate/polylysine complex for encapsulation of pancreatic islets. Characteristic to this type of capsule is, that it consists of a plain membrane which is formed during a single procedural step. With such a simple process it is difficult to obtain instantly a membrane optimized with respect to all the properties requested for islet transplantation. To overcome these difficulties, it is recommended to build up the membrane in several consecutive steps, each optimized for a certain property. In this study, we have analysed such a multilayer microcapsule for the encapsulation of pancreatic islets. Therefore, empty and islet contai…
A free plate model can predict guided modes propagating in tubular bone-mimicking phantoms
2014
The goal of this work was to show that a non-absorbing free plate model can predict with a reasonable accuracy guided modes measured in bone-mimicking phantoms that have circular cross-section. Experiments were carried out on uncoated and coated phantoms using a clinical axial transmission setup. Adjustment of the plate model to the experimental data yielded estimates for the waveguide characteristics (thickness, bulk wave velocities). Fair agreement was achieved over a frequency range of 0.4 to 1.6 MHz. A lower accuracy observed for the thinnest bone-mimicking phantoms was caused by limitations in the wave number measurements rather than by the model itself.
Efecto de la estimulación multipunto del ventrículo izquierdo en la terapia de resincronización cardíaca sobre la asincronía y la contractilidad mioc…
2018
Introducción La terapia de resincronización cardíaca (TRC) ha demostrado ser capaz de reducir la morbilidad y la mortalidad en pacientes con insuficiencia cardíaca, mala función ventricular izquierda y un QRS ensanchado. Desafortunadamente hasta un 20% de los pacientes no responden a esta terapia. Parte de los casos de no respuesta a la TRC son atribuibles a la corrección incompleta de la asincronía ventricular existente. Se ha postulado que la estimulación simultanea desde varios puntos del ventrículo izquierdo (VI) puede capturar una mayor masa miocárdica y reducir el tiempo de activación ventricular y, por tanto la asincronía. Hipótesis. La TRC realizada mediante estimulación multipunto …
Microleakage and shear bond strength of orthodontc brackets bonded to hypomineralized enamel following different surface preparations
2014
Objectives: This study investigated the effects of several conditioning methods on shear bond strength (SBS) and microleakage of orthodontic brackets bonded to demineralized enamel. Study Design: One hundred premolars were selected and immersed in a cariogenic solution for 12 weeks. The teeth were randomly assigned into 5 groups. In groups 1 and 2, the teeth underwent acid etching for 30 and 120 seconds, respectively. In group 3, a combination of laser and acid etching was employed. A self-etch primer (SEP) was applied in group 4 and in group 5, the teeth were exposed to acidulated phosphate fluoride (APF) for 4 minutes before etching. After bracket bonding, the teeth were immersed in methy…
Influence of artificial aging and ZrO2 nanoparticle-reinforced repair resin on the denture repair strength
2019
Background The purpose of this study was to evaluate the effect of aging process on the tensile strength (TS) of repaired acrylic denture base using ZrO2 nanoparticles (nano-ZrO2)-reinforced autopolymerized resin. Material and Methods A total of 240 heat-polymerized acrylic resin specimens (n=10) were prepared and sectioned creating 2 mm-repair-gap. Autopolymerized acrylic resin, pure and modified with 2.5, 5, and 7.5wt% nano-ZrO2 were used for specimens repair. TS of repaired specimens were measured using the universal testing machine after water immersion at 37oC for 2, 7 and 30 days. At each time interval, half the immersed specimens underwent thermo-cycling aging process (5000 cycles at…
Gas chromatography-mass spectrometry characterization of the varnish and glue of an ancient 18th century double bass.
2007
A GC–MS investigation is conducted on the double bass “Panormus”, property of Conservatorio di Musica “Vincenzo Bellini” in Palermo. The most important components of the varnish (fatty acids) and of the glue (proteinaceous amino acids), with which the musical instrument was treated in the past, are determined. The analyses are carried out by prior derivatization of fatty acids by acidic methanol and of amino acids by acidic methanol and trifluoroacetic anhydride (TFAA). Analytes identification is achieved by direct comparison with several reference materials and the use of a digitized library.