Search results for " resolution"
showing 9 items of 1159 documents
Characterization of a CZT focal plane small prototype for hard X-ray telescope
2005
The promise of good energy and spatial resolution coupled with high efficiency and room temperature operation has fuelled a large international effort to develop cadmium zinc telluride (CZT) for hard X-ray applications. We are involved on the development of a hard X-ray telescope based on multilayer optics and focal plane detector operative in the 10-80 keV energy range. This telescope requires a high efficiency focal plane providing both fine spatial resolution and spectroscopy with a compact and robust design. This paper reports preliminary results on the characterization both in spectroscopic and spatial response of two small pixellated CZT detectors (10times10times1 mm3 and 10times10tim…
High-resolution spectroscopy and analysis of the ν4 band of 80SeF6
2001
Abstract The Fourier-transform spectrum of the ν4 bending region of 80 SeF 6 around 435 cm −1 has been recorded at a temperature of 217 K with a resolution of 2.3×10 −3 cm −1 . This fundamental has been analyzed using the set of programs called highly spherical top data system (HTDS). Altogether 958 transitions were assigned and fitted with an rms of 0.0003 cm −1 . The effective Hamiltonian was developed up to the fourth order. Parameters and simulations are presented. The ν4 band center is located at 435.099 cm −1 .
Biomass estimator for NIR image with a few additional spectral band images taken from light UAS
2012
A novel way to produce biomass estimation will offer possibilities for precision farming. Fertilizer prediction maps can be made based on accurate biomass estimation generated by a novel biomass estimator. By using this knowledge, a variable rate amount of fertilizers can be applied during the growing season. The innovation consists of light UAS, a high spatial resolution camera, and VTT's novel spectral camera. A few properly selected spectral wavelengths with NIR images and point clouds extracted by automatic image matching have been used in the estimation. The spectral wavelengths were chosen from green, red, and NIR channels.
Curvelet-based method for orientation estimation of particles from optical images
2014
A method based on the curvelet transform is introduced to estimate the orientation distribution from two-dimensional images of small anisotropic particles. Orientation of fibers in paper is considered as a particular application of the method. Theoretical aspects of the suitability of this method are discussed and its efficiency is demonstrated with simulated and real images of fibrous systems. Comparison is made with two traditionally used methods of orientation analysis, and the new curvelet-based method is shown to perform better than these tradi- tional methods. © The Authors. Published by SPIE under a Creative Commons Attribution 3.0 Unported License. Distribution or reproduction of th…
Sensitivity of bipartite network analyses to incomplete sampling and taxonomic uncertainty
2023
Bipartite network analysis is a powerful tool to study the processes structuring interactions in ecological communities. In applying the method, it is assumed that the sampled interactions provide an accurate representation of the actual community. However, acquiring a representative sample may be difficult as not all species are equally abundant or easily identifiable. Two potential sampling issues can compromise the conclusions of bipartite network analyses: failure to capture the full range of interactions (sampling completeness) and use of a taxonomic level higher than species to evaluate the network (taxonomic resolution). We asked how commonly used descriptors of bipartite antagonisti…
High-Frequency and Ultra-High Frequency Ultrasound: Musculoskeletal Imaging up to 70 MHz
2020
AbstractMusculoskeletal (MSK) ultrasound has well-established advantages, able to investigate very small structures with high resolution and a quick and real-time dynamic evaluation with the possibility of contralateral comparison. Thus ultrasound has kept its own almost exclusive fields of application in daily clinical practice, and it is considered the first-level imaging technique to assess tendons, bursae, and capsuloligamentous structures of small peripheral joints as well as peripheral nerves. Up to now, however, clinical MSK ultrasound imaging could not go beyond the first 1 to 2 cm under the skin, using high-frequency probes up to 18 to 20 MHz with spatial resolution just below mill…
Lidar detection of carbon dioxide in volcanic plumes
2015
Volcanic gases give information on magmatic processes. In particular, anomalous releases of carbon dioxide precede volcanic eruptions. Up to now, this gas has been measured in volcanic plumes with conventional measurements that imply the severe risks of local sampling and can last many hours. For these reasons and for the great advantages of laser sensing, the thorough development of volcanic lidar has been undertaken at the Diagnostics and Metrology Laboratory (UTAPRAD-DIM) of the Italian National Agency for New Technologies, Energy and Sustainable Economic Development (ENEA). In fact, lidar profiling allows one to scan remotely volcanic plumes in a fast and continuous way, and with high s…
Recognizing Video Resolution by Monitoring Memory Metrics in Mobile Clients
2019
Content delivery is one of the most successful applications in mobile networks. Mobile edge servers are significantly contributing to the improvement of this type of applications, by also performing resolution adaptations as a function of the radio link quality observed by the users. In this paper, we face the problem of dynamically tracking the perceived video resolution by mobile clients in a mobile edge environment to guarantee an agreed Service Level Agreement (SLA). To this purpose, we propose a protocol-agnostic approach, based on monitoring some memory metrics of a running video streaming process at the mobile client, for identifying the time-varying resolution of the video content.
The Large Observatory For x-ray Timing
2014
The Large Observatory For x-ray Timing (LOFT) was studied within ESA M3 Cosmic Vision framework and participated in the final down-selection for a launch slot in 2022-2024. Thanks to the unprecedented combination of effective area and spectral resolution of its main instrument, LOFT will study the behaviour of matter under extreme conditions, such as the strong gravitational field in the innermost regions of accretion flows close to black holes and neutron stars, and the supra-nuclear densities in the interior of neutron stars. The science payload is based on a Large Area Detector (LAD, 10 m 2 effective area, 2-30 keV, 240 eV spectral resolution, 1 deg collimated field of view) and a WideFi…