Search results for " sample"
showing 10 items of 456 documents
Flow injection near-infrared determination of ethanol in chloroform
1995
A simple and direct flow injection (FIA) procedure has been developed for the determination of the stabilizing agent ethanol in chloroform samples. The procedure is based on the use of the absorbance band of ethanol in the near-infrared (NIR) region at 2272 nm, measured in front of a reference sample of chloroform stabilized with amylene. The method developed provides a limit of detection of 0.0045% (v/v) and a dynamic range until 10% (v/v) with a typical variation coefficient of 0.4% for six independent analysis of a real sample containing approximately 1% (v/v) of ethanol. The sample injection frequency allowed by the method is 78 h−1.
Method and apparatus using selected superparamagnetic labels for rapid quantification of immunochromatographic tests
2009
Mika PA Laitinen1, Jari Salmela2, Leona Gilbert1, Risto Kaivola1, Topi Tikkala2, Christian Oker-Blom1, Jukka Pekola3, Matti Vuento11Department of Biological and Environmental Science; 2Department of Physics, University of Jyväskylä, Jyväskylä, Finland; 3Low Temperature Laboratory, Helsinki University of Technology, Helsinki, FinlandAbstract: A rapid method and instrumentation for quantification of immunochromatographic tests (ICT) are described. The principle and performance of the method was demonstrated by measuring the levels of human chorionic gonadotropin (hCG) present in urine. The test format was a sandwich assay using two distinct monoclonal antib…
A tandem-flow assembly for the chemiluminometric determination of hydroquinone
2003
A direct chemiluminescent procedure for determination of hydroquinone based on the emergent flow methodology known as multicommutation or tandem-flow is presented for first time. The manifold was based on a set of three channels and three solenoid valves; and, the determination was performed at 60degreesC and at flow-rate of 7.5 ml min(-1). The complete cycle lasted 35 s, which resulted in a sample flow trough of 103 h(-1). The chemical process was the hydroquinone oxidation with the system sulphuric acid-potassium permanganate; and the light emission was clearly enhanced by the presence of quinine sulphate and benzalkonium chloride reaching a detection limit of 30 Rg l(-1). The dynamic int…
On-line preconcentration strategies for analyzing pesticides in fruits and vegetables by micellar electrokinetic chromatography.
2007
Five pesticides (fludioxonil, procymidone, pyriproxyfen, dinoseb and carbendazim) were separated in reversed migration micellar electrokinetic chromatography (RM-MEKC) using 20 mmol l(-1) phosphate buffer at pH 2.3, containing 25 mmol l(-1) sodium dodecylsulfate and 10% methanol. Three on-line concentration strategies, sweeping (SW), normal stacking with reversed migration and a water plug (SRW) and stacking with reverse migration and removal of sample matrix using polarity switching (SRMM), were compared. About 10-, 30- and 50-fold increases in detection sensitivity, compared with standard hydrodynamic injection (5 s at 0.5 psi), were observed with SW, SRW and SRMM, respectively. Limits of…
Solid glucose biosensor integrated in a multi-well microplate coupled to a camera-based detector: Application to the multiple analysis of human serum…
2018
Abstract In the present work, a biosensor adapted in a 96-well microplate has been coupled with a smartphone-based photometer in order to develop a low-cost colorimetric multi-sample dispositive. The strength of this biosensing system is based on the integration of the biosensor into the 96-well microplate and the use of a smartphone and free image analysis software as a microplate reader. The performance of the proposed biosensor has been demonstrated to determine glucose in several human serum samples. This method is simple, cost-effective, sensitive and selective for the determination of glucose in serum, with detection limits of 1.8 mg/dL and a good linearity over the range 6–88 mg/dL. …
Thermal Lens Spectrometric Detection of Catecholamines after Oxidation to Aminochromes
1992
Abstract Experimental conditions for the spectrophotometric and thermal lens spectrometry (TLS) detection of catecholamines after oxidation to aminochromes with hexacyanoferrate (III) are optimized. At the low concentrations used in TLS, and in a 0.07 M citrate buffer, catecholamine oxidation can be performed at pH 7 and is immediate, whereas a lower pH value is required in spectrophotometry to avoid aminochrome polymerisation, the oxidation reactions being much slower. Similar TLS sensitivities are obtained for all catecholamines which facilitates HPLC evaluation. Sensitivity can be enhanced using a 50% ethanol-water medium. The linear dynamic range extends over two orders of magnitude, th…
Las representaciones del saber académico: Aportaciones desde la Geografía Escolar
2019
When we talk with basic education´s teachers there is an impression in the case of learning Social Sciences, and Geography in particular that these sciences are not useful for the explanation of socio-environmental and daily problems. In this research, improvement proposals are sought so that students are motivated to learn about these problems. Based on two case studies such as flood risks (and their relationship with climate change) and the problems of the rural areas, the possibilities of combining motivation for learning close to personal emotions and with their own rigor have been explored of the conceptual explanation. To validate these results, quantitative and qualitative research t…
Structural study of α-Bi2O3 under pressure
2013
An experimental and theoretical study of the structural properties of monoclinic bismuth oxide (alpha-(BiO3)-O-2) under high pressures is here reported. Both synthetic and mineral bismite powder samples have been compressed up to 45 GPa and their equations of state have been determined with angle-dispersive x-ray diffraction measurements. Experimental results have been also compared with theoretical calculations which suggest the possibility of several phase transitions below 10 GPa. However, experiments reveal only a pressure-induced amorphization between 15 and 25 GPa, depending on sample quality and deviatoric stresses. The amorphous phase has been followed up to 45 GPa and its nature di…
Sample Preparation to Determine Pharmaceutical and Personal Care Products in an All-Water Matrix: Solid Phase Extraction
2020
© 2020 by the authors. Pharmaceuticals and personal care products (PPCPs) are abundantly used by people, and some of them are excreted unaltered or as metabolites through urine, with the sewage being the most important source to their release to the environment. These compounds are in almost all types of water (wastewater, surface water, groundwater, etc.) at concentrations ranging from ng/L to µg/L. The isolation and concentration of the PPCPs from water achieves the appropriate sensitivity. This step is mostly based on solid-phase extraction (SPE) but also includes other approaches (dispersive liquid-liquid microextraction (DLLME), buckypaper, SPE using multicartridges, etc.). In this rev…
A Colorimetric Membrane-Based Sensor with Improved Selectivity towards Amphetamine
2021
Due to their simplicity, speed and low cost, chemical spot tests are increasingly demanded for the presumptive identification of illicit drugs in a variety of contexts such as point-of-care assistance or prosecution of drug trafficking. However, most of the colorimetric reactions used in these tests are, at best, drug class selective. Therefore, the development of tests based on chemical reactions with improved discrimination power is of great interest. In this work, we propose a new colorimetric assay for amphetamine (AMP) based on its reaction with solutions of alkaline gold bromide to form an insoluble yellow–orange derivative. The resulting suspensions are then filtered onto nylon membr…