Upper limits on the isotropic gravitational-wave background from Advanced LIGO and Advanced Virgo's third observing run
2021
We report results of a search for an isotropic gravitational-wave background (GWB) using data from Advanced LIGO's and Advanced Virgo's third observing run (O3) combined with upper limits from the earlier O1 and O2 runs. Unlike in previous observing runs in the advanced detector era, we include Virgo in the search for the GWB. The results are consistent with uncorrelated noise, and therefore we place upper limits on the strength of the GWB. We find that the dimensionless energy density $\Omega_{\rm GW}\leq 5.8\times 10^{-9}$ at the 95% credible level for a flat (frequency-independent) GWB, using a prior which is uniform in the log of the strength of the GWB, with 99% of the sensitivity comi…
Presbiopijas korekcija ar multifokālajām intraokulārajām lēcām
2017
Bakalaura darbs ir uzrakstīts angļu valodā uz 47 lapaspusēm. Tas satur 3 zīmējumus, 20 tabulas, 39 literatūras avotus un pielikumu. Darba mērķis ir salīdzināt divu jaunu intraokulāro lēcu (difraktīvā trifokālā lēca un paplašināta fokusa dziļuma multifokālā lēca) efektivitāti presbiopija korekcijā pēc kataraktas operācijas. Pētījumi tika veikti 3 mēnešu periodā pēc kataraktas operācijas, kad tika novērtēta redzes kvalitāte, mērot redzes asumu un kontrasta redzi fotopiskos gaismas un mezopiskos krēslas apstākļos. Abi introokulāro lēcu veidi nodrošināja lielisku redzes asumu visos skata attālumos un pilnu neatkarību no brillēm. Taču kontrasta jūtība un redzes asums mezopiskos krēslas apstākļos…
Visual Acuity and Contrast Sensitivity Depending from Keratoconus Apex Position
2017
Abstract Various studies have demonstrated that patients with keratoconus have significant loss of contrast sensitivity while its value varies in different studies. None of these studies has analysed reduced contrast sensitivity depending on the position of apex of corneal conus. Visual acuity and contrast sensitivity were evaluated for patients with keratoconus using the FrACT software. Contrast sensitivity was assessed at the following frequencies: 1, 3, 5, 7, 9, 11, 13, and 15 cycles per degree (cpd). Twenty-four eyes with keratoconus were analysed. Contrast sensitivity was significantly lower for patients with the apex at the centre compared with apex on the periphery both with (p = 0.0…
Pelēki tonētu lēcu ietekme uz redzes funkcijām
2017
Darbs ir uzrakstīts andļu valodā uz 27 lapaspusēm, tajā ir 12 attēli, 2 tabulas un 36 litteratūras avoti. Darba mērķis bija novērtēt, kā samazināta apgaismojuma apstākļi ietekmē redzes funkcijas gados jaunākiem un vecākiem dalībniekiem. Gados jauniem (21 – 35 gadi) un vecākiem (60 – 75 gadi) dalībniekiem tika mērīts augsta un zema kontrasta redzes asums. Mērījumi tika veikti ar un bez pelēki tonētām lēcām, kuru gaismas caurlaidība bija 50 %. Rezultāti parādīja, ka lielāks redzes asuma samazinājums, samazinoties optotipu kontrastam, bija novērojams gados vecākiem dalībniekiem. Skatoties caur tonētajām lēcām, standarta kontrasta redzes asums vairāk samazinājās gados vecākiem nekā jaunākiem da…
Acs optiskās kvalitātes ietekme uz kontrastjutību un redzes asumu
2017
Darbs ir uzrakstīts angļu valodā uz 50 lapaspusēm, satur 37 figūras, 1 tabula un 41 literatūras avotus. Pētījuma mērķis bija novērtēt redzes kvalitāti dalībniekiem ar dažādām izmaiņām acs optiskajās vidēs. Augsta kontrasta redzes asums, mezopiskais redzes asums un kontrastjutība ir labi parametri acs optiskās kvalitātes novērtēšanai. Mezopiskais redzes asums ir ar augstu jutību, lai atklātu dalībniekus ar nelielas pakāpes apduļķojumiem acs optiskajās vidēs (agrīna katarakta). Kontrastjutības tests ir jutīgs uz izmaiņām acs optiskajās vidēs dalībniekiem ar ortokeratoloģijas lēcām. Augsta kontrasta redzes asums ir pietiekami jutīgs uz cita veida izmaiņām acs struktūrās
Entrenamiento perceptual, test de caras sonrientes
2016
Este software es una programa de entrenamiento perceptual con estímulos acromáticos de contraste variable, sobre ruído aleatorio sintonizado a una banda de frecuencia. La aplicación ha sido desarrollada dentro en el marco de un estudio sobre la ambliopía, realizado por la profesora Rosa Hernández, y está todavía en proceso de evaluación. This is perceptual training software using achromatic stimuli with variable contrast and random noise tuned to a particular frequency bandwith. This app has been developed in the context of a study of amblyopia, carried out by professor Rosa Hernández, and is still under testing.
Redzes funkciju izvērtējums pacientiem agrīnā presbiopijas vecumā ar vienas dienas multifokālajām kontaktlēcām
2017
Bakalaura darbs uzrakstīts uz 27 lapaspusēm, satur 18 zīmējumus, 1 tabulu un 20 literatūras avotus. Darba mērķis ir novērtēt redzes asumu un kontrasta jūtību fotopiskos un mezopiskos apstākļos pacientiem, koriģētiem ar brillēm un vienas dienas multifokālajām kontaktlēcām. Mūsu pētījumi parādīja, ka fotopiskos apstākļos pacientiem pēc korekcijas ar multifokālajām kontaktlēcām redzes asums vidēji samazinājās par 0,02 logMAR vienībām. Mezopiskos krēslas apstākļos pacientiem koriģētiem ar multifokālajām kontaktlēcām redzes asuma samazinājums vidēji bija 0.05 logMAR vienības. Atšķirības redzes asumā ir statistiski nozīmīgas. Kontrasta jūtības vidējie lielumi pēc kontaktlēcu uzlikšanas vidēji sam…
Koriģētais redzes asums, kontrastjutība un aberācijas keratokonusa pacientiem atkarībā no virsotnes atrašanās vietas
2018
Promocijas darbs ir uzrakstīts angļu valodā uz 29 lappusēm. Tajā ir 17 attēli, 2 tabulas un 26 atsauces. Mērķis. Novērtēt keratokonusa virsotnes radītās izmaiņas redzes asumā, kontrastjutībā un aberācijās. Metode. Noteikts redzes asums un kontrastjutība piecās dažādās frekvencēs ar FrACT programmu, lietojot briļļu un kontaktlēcu korekciju. Noteikts zīlītes diametra mērījums un topogrāfiskā karte ar Keratronu un Optikon. Rezultāti. Salīdzinot pacientus ar keratokonusa virsotni centrā un perifērijā, redzes asums ir statistiski nozīmīgi lielāks pacientiem ar keratokonusa virsotni centrā ar alfa=10% līmeni. Kontrastjutība ir statistiski nozīmīgi atšķirīga pacientiem, kuri lieto brilles un cietā…
Maza izmēra diafragmas ietekme uz redzes asumu un kontrastjutību
2016
Bakalaura darbs ir uzrakstīts latviešu valodā uz 27 lapām. Satur 16 attēlus, 1 tabulu, 1 pielikumu un 27 atsauces uz literatūras avotiem. Darba mērķis: Noskaidrot kontrastjutības un redzes asuma izmaiņas apertūras ietekmē Metodika: Eksperimentālajā daļā dalībniekiem tika noteikts redzes asums un kontrastjutība ar FrACT datorizēto testu ar un bez maza izmēra diafragmas. Secinājumi: Diafragmas ietekmē kontrastjutība samazinājās visiem dalībniekiem. Redzes asums diafragmas ietekmē uzlabojās tiem dalībniekiem, kuriem redzes asums sākumā bija zems, bet pasliktinājās tiem dalībniekiem, kuriem redzes asums sākumā bija augsts. Atslēgas vārdi: redzes asums, kontrastjutība, maza izmēra diafragma
Status of Advanced Virgo
2017
The LIGO and the Virgo collaborations have recently announced the first detections of Gravitational Waves. Due to their weak amplitude, Gravitational Waves are expected to produce a very small effect on free-falling masses, which undergo a displacement of the order of 10-18 m for a Km-scale mutual distance. This discovery showed that interferometric detectors are suitable to reveal such a feeble effect, and therefore represent a new tool for astronomy, astrophysics and cosmology in the understanding of the Universe. To better reconstruct the position of the Gravitational Wave source and increase the signal-to-noise ratio of the events by means of multiple coincidence, a network of detectors…