Search results for " spread"
showing 10 items of 241 documents
Flux and color variations of the quadruply imaged quasar HE 0435-1223
2011
aims: We present VRi photometric observations of the quadruply imaged quasar HE 0435-1223, carried out with the Danish 1.54m telescope at the La Silla Observatory. Our aim was to monitor and study the magnitudes and colors of each lensed component as a function of time. methods: We monitored the object during two seasons (2008 and 2009) in the VRi spectral bands, and reduced the data with two independent techniques: difference imaging and PSF (Point Spread Function) fitting.results: Between these two seasons, our results show an evident decrease in flux by ~0.2-0.4 magnitudes of the four lensed components in the three filters. We also found a significant increase (~0.05-0.015) in their V-R …
Diffractive corneal inlay for presbyopia
2017
[EN] A conceptually new type of corneal inlays for a customized treatment of presbyopia is presented. The diffractive inlay consists on a small aperture disc having an array of micro-holes distributed inside the open zones of a Fresnel zone plate. In this way, the central hole of the disc lets pass the zero order diffraction and produces an extension of the depth of far focus of the eye, while the diffracted light through the holes in the periphery produce the near focus. Additionally, the micro-holes in the inlay surface fulfill the essential requirement of allowing the flow of nutrients through it to the cells of the corneal stroma. Theoretical and optical-bench experimental results for t…
Imaging Performance of a Diffractive Corneal Inlay for Presbyopia in a Model Eye
2019
[EN] In this work we evaluated the imaging properties of the Diffractive Corneal Inlay (DCI), a novel type of corneal implant working by diffraction that we proposed for the treatment of presbyopia. ZEMAX OpticStudio software was employed for the numerical assessment, with simulations performed in a human-based eye model. In the ray tracing analysis, we used the Modulation Transfer Function (MTF), the Area under the MTF (AMTF), and the Point Spread Function (PSF). The theoretical performance of the DCI under different situations was evaluated in comparison with a commercially available pinhole based corneal inlay. Finally, real images were obtained experimentally in vitro in a model eye wit…
Multitemporal fusion of Landsat/TM and ENVISAT/MERIS for crop monitoring
2013
Abstract Monitoring Earth dynamics using current and future satellites is one of the most important objectives of the remote sensing community. The exploitation of image time series from sensors with different characteristics provides new opportunities to increase the knowledge about environmental changes and to support many operational applications. This paper presents an image fusion approach based on multiresolution and multisensor regularized spatial unmixing. The approach yields a composite image with the spatial resolution of the high spatial resolution image while retaining the spectral and temporal characteristics of the medium spatial resolution image. The approach is tested using …
Quasi-spherical focal spot in two-photon scanning microscopy by three-ring apodization
2005
International audience; We present a beam-shaping technique for two-photon excitation (TPE) fluorescence microscopy. We show that by inserting a properly designed three-ring pupil filter in the illumination beam of the microscope, the effective optical sectioning capacity of such a system improves so that the point spread function gets a quasi-spherical shape. Such an improvement, which allows the acquisition of 3D images with isotropic quality, is obtained at the expense of only a small increase of the overall energy in the axial sidelobes. The performance of this technique is illustrated with a scanning TPE microscopy experiment in which the image of small beads is obtained. We demonstrat…
Total Variation Based Image Restoration
2004
For the purpose of image restoration the process of image formation can be modeled in a first approximation by the formula [207] $$ {u_d} = Q\{ II(k*u) + n\} , $$ (1.1) where u represents the photonic flux k is the point spread function of the optical-captor joint apparatus П is a sampling operator, i.e., a Dirac comb supported by the centers of the matrix of digital sensors, n represents a random perturbation due to photonic or electronic noise, and Qis a uniform quantization operator mapping ℝ to a discrete interval of values, typically [0, 255].
Resolution enhancement in integral microscopy by physical interpolation
2015
Integral-imaging technology has demonstrated its capability for computing depth images from the microimages recorded after a single shot. This capability has been shown in macroscopic imaging and also in microscopy. Despite the possibility of refocusing different planes from one snap-shot is crucial for the study of some biological processes, the main drawback in integral imaging is the substantial reduction of the spatial resolution. In this contribution we report a technique, which permits to increase the two-dimensional spatial resolution of the computed depth images in integral microscopy by a factor of √2. This is made by a double-shot approach, carried out by means of a rotating glass…
Clinical use of the ocular point spread function for retinal image quality assessment
2008
The purpose of this study is to demonstrate the clinical use of the point spread function (PSF) as metric for the assessment of retinal image quality in eyes with different ocular conditions. The PSF was computed from the wavefront aberrations obtained in seven eyes with different ocular conditions: emmetropia, myopia, hyperopia, post-myopic laser in situ keratomileusis (LASIK), post-hyperopic LASIK, keratoconus, Intacs ® in keratoconus, radial keratotomy (RK), LASIK after RK, cataract, phacoemulsification after cataract surgery, and LASIK after astigmatic keratotomy. The Strehl intensity ratio was calculated for all the PSFs computed. The PSF was correlated with the change in the optical e…
Multiframe image restoration in the presence of noisy blur kernel
2009
We wish to recover an original image u from several blurry-noisy versions f k , called frames. We assume a more severe degradation model, in which the image u has been blurred by a noisy (stochastic) point spread function. We consider the problem of restoring the degraded image in a variational framework. Since the recovery of u from one single frame f is a highly ill-posed problem, we formulate two minimization problems based on the multiframe approach proposed for image super-resolution by Marquina-Osher [13]. Several experimental results for image restoration are shown, illustrating that the proposed models give visually satisfactory results.
Through-focus response of multifocal intraocular lenses evaluated with a spatial light modulator
2012
A new testing technique based on the use of a liquid crystal spatial light modulator (SLM) is proposed to analyze the optical quality of multifocal intraocular lenses (MIOLs). Different vergences and decentrations of the incident beam can be programmed onto the SLM in order to record the point spread function (PSF) for different object positions. From these axial PSFs, the through-focus modulation transfer function is computed. Because there are no moving parts in the experimental setup, this method is fast and versatile to assess MIOLs. Experimental results confirm the potential of the proposed method.