Search results for " standard"
showing 10 items of 1548 documents
Association between xerostomia, oral and general health, and obesity in adults. A cross-sectional pilot study.
2021
Background The objective of this study was to analyse the association between oral and general health variables and obesity indicators with the sensation of dry mouth or xerostomia as evaluated on the Xerostomia Inventory (XI). Material and Methods A total of 354 randomly selected subjects participated in this cross-sectional pilot study and completed an anonymous questionnaire. Anthropometric, clinical, and xerostomic variables were evaluated. Kruskal-Wallis, ANOVA and Bonferroni test were used for multiple comparisons. ROC curves and multinomial logistic regression were used to determine the (OR) risk of xerostomia. Results A total of 30.7 % of respondents reported xerostomia based on XI.…
Comparison and interpretability of the available urticaria activity scores
2017
The urticaria activity score (UAS) is the gold standard for assessing disease activity in patients with chronic spontaneous urticaria (CSU). Two different versions, the UAS7 and UAS7TD , are currently used in clinical trials and routine care. To compare both versions and to obtain data on their interpretability, 130 CSU patients applied both versions and globally rated their disease activity as none, mild, moderate, or severe. UAS7 and UAS7TD values correlated strongly (r = .90, P < .001). Interquartile ranges for UAS7 and UAS7TD values for mild, moderate, and severe CSU were 11-20 and 10-24, 16-30 and 16-32, and 27-37 and 28-40. UAS7 values were slightly, but significantly lower as compare…
Clinical evaluation of a wireless ECG sensor system for arrhythmia diagnostic purposes
2013
Accepted version of an article in the journal: Medical Engineering and Physics. Also available from the publisher at: http://dx.doi.org/10.1016/j.medengphy.2013.03.002 In a clinical study, a novel wireless electrocardiogram (ECG) recorder has been evaluated with regard to its ability to perform arrhythmia diagnostics. As the ECG recorder will detect a "non-standard" ECG signal, it has been necessary to compare those signals to "standard" ECG recording signals in order to evaluate the arrhythmia detection ability of the new system. Simultaneous recording of ECG signals from both the new wireless ECG recorder and a conventional Holter recorder was compared by two independent cardiology specia…
Blood flow velocity waveforms of the fetal middle cerebral artery in a normal population: reference values from 18 weeks to 42 weeks of gestation
2002
The aim of this prospective cross-sectional study was to establish new Doppler reference curves for peak blood flow velocities (Vmax, Vmean, Vmin) and impedance indices (PI, RI) of the middle cerebral artery at 18-42 weeks of gestation by an automatic wave form analysis integrated into the ultrasound device. In 962 low-risk pregnancies, blood flow velocities were derived from the middle cerebral artery with pulsed color Doppler ultrasonography. Reference curves were constructed for the individual parameters based on a growth function from a four-parameter class of monotonic continuous functions according to the smallest square principle for maximum blood flow velocities, as well as on a pol…
Ultrasound-Guided Breast-Conservative Surgery Decreases the Rate of Reoperations for Palpable Breast Cancer
2018
The purpose of this study is to verify whether the performance of ultrasound-guided quadrantectomy (USGQ) versus palpation-guided quadrantectomy (PGQ) can reduce the incidence of positive margins and if it can change the attitude of the surgeon. A retrospective study was conducted on 842 patients underwent quadrantectomy for breast cancer, 332 of them underwent USGQ, whereas 550 underwent PGQ. The histological type of the tumors and the margin status obtained with the histological examination were compared. The histological examination of the surgical specimen showed involvement of the margins in 24/842 patients (2.85%), 22 (2.61%) of them belonged to the PGQ group, and two to the USGQ gro…
Cervical carcinoma: standard and pharmacokinetic analysis of time-intensity curves for assessment of tumor angiogenesis and patient survival
1999
Since detailed knowledge regarding the pathophysiological properties—which in turn are responsible for differences in contrast enhancement—remain fairly undetermined, it was the aim of this study (i) to examine the association of standard and pharmacokinetic analysis of time-intensity curves in dynamic MRI with histomorphological markers of tumor angiogenesis (microvessel density [MVD]; vascular endothelial growth factor [VEGF]) and (ii) to determine the ultimate value of a histomorphological and a dynamic MRI approach by correlation of those data with disease outcome in patients with primary cancer of the uterine cervix. Pharmacokinetic parameters (amplitude A, exchange rate constantk 21) …
Comparison of high-pressure liquid chromatography (HPLC) and Griess reagent-spectroscopic methods for the measurement of nitrate in serum from health…
2008
Bioavailability of NO can be estimated by measuring the concentration of nitrate (NO(3)) in serum. However, the methods used for the measurement NO(3) in plasma or serum show a great degree of variation. Therefore, we compared two analytical methods for the measurement of NO(3) in serum.The concentration of NO(3) in 600 serum samples collected from healthy individuals was determined by the HPLC and by the Griess reagent-spectroscopic method.The concentration of NO(3) in the samples was 29.4+/-16.1 micromol/L and 26.2+/-14.0 micromol/L (mean+/-SD) measured by HPLC and Griess reagent-spectroscopic method respectively (p0.0001). We detected a significant correlation between the two methods (R=…
Evaluation of saliva as a complementary technique to the diagnosis of COVID-19:a systematic review
2021
Background Infectious disease coronavirus 2019 (COVID-19) is caused by the SARS-CoV-2 virus, and it mainly affects the upper respiratory tract. The gold standard for its diagnosis is real-time reverse transcription polymerase chain reaction (RT-qPCR) performed on a nasopharyngeal swab. In contrast, testing saliva has significant advantages as a diagnostic method. Material and Methods We searched for articles evaluating saliva as a diagnostic method for COVID-19 on the PUBMED/MEDLINE, WEB OF SCIENCE, COCHRANE, and SCIELO platforms. We initially found 233 articles and 20 were selected for inclusion following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses protocol: 18 c…
Imaging of sarcopenia.
2016
Sarcopenia is currently considered a geriatric syndrome increasing in older people. The consequences of sarcopenia – in terms of impaired mobility, limited self-sufficiency and disability – have been amply demonstrated, increasing the need to develop methods to identify muscle mass loss as early as possible. Although sarcopenia involves a reduction in both muscle mass and function, loss of muscle mass remains the essential criterion for diagnosing this condition in daily practice. Computed tomography and magnetic resonance imaging represent the gold standard for studying body composition, and can identify quantitative and qualitative changes in muscle mass. These techniques are costly, time…
The smokeless tobacco habit and DNA damage: A systematic review and meta-analysis.
2018
Background The aim of this systematic review was to evaluate the frequency of micronuclei or other DNA damage in the oral mucosa of adults that have smokeless tobacco habits compared to adults that not have these habits. Material and Methods We searched PubMed, Scopus, Web of Science, LILACS, BBO and Cochrane Library and SIGLE. We also surveyed gray literature. We included only clinical trials that compare the frequency of micronuclei or other DNA damage in the oral mucosa of adults that have smokeless tobacco habits compared to adults that not have these habits. Quality assessments of the selected trials were evaluated by two independent reviewers, using the Effective Public Health Practic…