Search results for " stenosi"
showing 10 items of 306 documents
Pre-operative Diagnosis of Silent Coronary Ischaemia May Reduce Post-operative Death and Myocardial Infarction and Improve Survival of Patients Under…
2019
Objective Patients undergoing peripheral vascular surgery have increased risk of death and myocardial infarction (MI), which may be due to unsuspected (silent) coronary ischaemia. The aim was to determine whether pre-operative diagnosis of silent ischaemia using coronary computed tomography (CT) derived fractional flow reserve (FFRCT) can facilitate multidisciplinary care to reduce post-operative death and MI, and improve survival. Methods This was a single centre prospective study with historic controls. Patients with no cardiac symptoms undergoing lower extremity surgical revascularisation with pre-operative coronary CTA-FFRCT testing were compared with historic controls with standard pre…
Second asymptomatic carotid surgery trial (ACST-2): a randomised comparison of carotid artery stenting versus carotid endarterectomy.
2021
Summary Background Among asymptomatic patients with severe carotid artery stenosis but no recent stroke or transient cerebral ischaemia, either carotid artery stenting (CAS) or carotid endarterectomy (CEA) can restore patency and reduce long-term stroke risks. However, from recent national registry data, each option causes about 1% procedural risk of disabling stroke or death. Comparison of their long-term protective effects requires large-scale randomised evidence. Methods ACST-2 is an international multicentre randomised trial of CAS versus CEA among asymptomatic patients with severe stenosis thought to require intervention, interpreted with all other relevant trials. Patients were eligib…
Optical Coherence Tomography Versus Intravascular Ultrasound to Evaluate Coronary Artery Disease and Percutaneous Coronary Intervention
2013
ObjectivesWe compared intravascular ultrasound (IVUS) and 2 different generations of optical coherence tomography (OCT)—time-domain OCT (TD-OCT) and frequency-domain OCT (FD-OCT)—for the assessment of coronary disease and percutaneous coronary intervention (PCI) using stents.BackgroundOCT is a promising light-based intravascular imaging modality with higher resolution than IVUS. However, the paucity of data on OCT image quantification has limited its application in clinical practice.MethodsA total of 227 matched OCT and IVUS pull backs were studied. One hundred FD-OCT and IVUS pull backs in nonstented (n = 56) and stented (n = 44) vessels were compared. Additionally, 127 matched TD-OCT and …
Immunoglobulin G4-Related Aortitis and Severe Aortic Valve Stenosis Treated With Transcatheter Aortic Valve Replacement and Immunosuppression.
2021
Abstract IgG4-related disease is an immune-mediated fibro-inflammatory disorder with multisystemic involvement. Aortitis and peri-aortitis are the most common cardiovascular manifestations of the disease. We present the case of a 65-year-old man with symptomatic severe aortic stenosis and concomitant IgG4 aortitis. The diagnosis was confirmed by IgG4 serum levels, positive positron emission computed tomography (PET-CT) scans, and pathology from mediastinal dissection. Surgical aortic valve replacement (SAVR) was unfeasible owing to extensive mediastinal fibrosis, and transcatheter aortic valve replacement (TAVR) was successfully performed. As ascending aorta access for SAVR in IgG4 aortitis…
Real world safety and efficacy of the Janus Tacrolimus-Eluting stent: long-term clinical outcome and angiographic findings from the Tacrolimus-Elutin…
2009
Objectives: We sought to evaluate the safety and performance of the Janus Tacrolimus-Eluting stent (TES) in an unselected population of patients, without application of restrictive clinical or angiographic criteria. Background: Continued attention to the safety, efficacy, and deliverability of first-generation drug eluting stents has led to the development of new antiproliferative agents with alternative stent platforms and different drug carrier vehicles. Methods: The TEST (Tacrolimus Eluting STent) registry is a prospective, nonrandomized single-center registry in which 140 consecutive patients who underwent single- or multi-vessel percutaneous coronary intervention between February 2005 …
Differential Prognostic Value of Galectin-3 According to Carbohydrate Antigen 125 Levels in Transcatheter Aortic Valve Implantation
2019
Galectin-3 (Gal-3) and carbohydrate antigen 125 (CA125) have been associated with adverse outcomes after transcatheter aortic valve implantation (TAVI). Experimental data have suggested a potential molecular interaction. Therefore, we assessed the association of Gal-3 and CA125 with prognosis after TAVI.A total of 439 patients were enrolled. The primary endpoint was a composite of all-cause mortality or readmission for worsening heart failure after TAVI.The primary endpoint occurred in 16.4%. Gal-3 was dichotomized at ≥ 8.71 ng/mL into elevated and not elevated. Gal-3 was elevated in 31.9% and was associated with a higher risk of the primary endpoint (25% vs 12.4%, HR, 2.26; P.001). After m…
Comparison of Carbohydrate Antigen 125 and N-Terminal Pro-Brain Natriuretic Peptide for Risk Prediction After Transcatheter Aortic Valve Implantation
2017
Elevated carbohydrate antigen 125 (CA125) and N-terminal pro-brain natriuretic peptide (NTproBNP) have been associated with adverse outcome after transcatheter aortic valve implantation (TAVI). This study performs a comparison of both biomarkers for prognosis after TAVI. The study includes 363 patients. The primary end point was all-cause death or readmission for worsening congestive heart failure within 1 year after TAVI, and this end point occurred in 16% of the population. The optimal cutoff to predict the primary end point was 18.4 U/ml for CA125 and 2,570 ng/L for NTproBNP. Elevated CA125 levels were present in 52% and were associated with a higher rate of the primary end point (27% vs…
Failed hypospadias in paediatric patients
2013
Failed hypospadias refers to any hypospadias repair that leads to complications or causes patient dissatisfaction. The complication rate after hypospadias repairs ranges from 5-70%, but the actual incidence of failed hypospadias is unknown as complications can become apparent many years after surgery and series with lifelong follow-up data do not exist. Moreover, little is known about uncomplicated repairs that fail in terms of patient satisfaction. Risk factors for complications include factors related to the hypospadias (severity of the condition and characteristics of the urethral plate), the patient (age at surgery, endocrine environment, and wound healing impairment), the surgeon (tech…
Fludarabine prevents smooth muscle proliferation in vitro and neointimal hyperplasia in vivo through specific inhibition of STAT-1 activation.
2007
Drug-eluting stents are increasingly used to reduce in-stent restenosis and adverse cardiac events after percutaneous coronary interventions. However, the race for the ideal drug-eluting stent is still on, with special regard to the best stent-coating system and the most effective and less toxic drug. Fludarabine, a nucleoside analog, has both anti-inflammatory and antiproliferative cellular effects. The aim of the present study was to assess the cellular and molecular effects of fludarabine on vascular smooth muscle cell (VSMC) growth in vitro and in vivo and the feasibility and efficacy of a fludarabine-eluting stent. To study the biomolecular effects of fludarabine on VSMC proliferation…
Walking Speed as an Alternative Measure of Functional Status in Patients with Lumbar Spinal Stenosis
2019
Objective The main objective was to compare estimated walking perimeter (WP) and actual WP during a free walking test (6-minute walk test [6MWT]) in patients with lumbar spinal stenosis (LSS). The second objective was to describe the correlation between measured gait parameters and functional parameters. Methods This was a single-center prospective study including 38 patients with symptomatic LSS (23 men, 15 women; mean age, 69.3 ± 7.9 years). The intervention was the 6MWT. For the main outcome measure, patients were first asked to verbally estimate their WP. Then, WP was evaluated using a 6MWT at a self-selected speed. In the absence of need to stop, and if a distance of 500 m was not reac…