Search results for " stenosi"

showing 6 items of 306 documents

Rates of Upper Facet Joint Violation in Minimally Invasive Percutaneous and Open Instrumentation: A Comparative Cohort Study of Different Insertion T…

2017

Background Minimally invasive pedicle screw placement may have a higher incidence of violation of the superior cephalad unfused facet joint. Study Aims We investigated the incidence and risk factors of upper facet joint violation in percutaneous robot-assisted instrumentation versus percutaneous fluoroscopy-guided and open transpedicular instrumentation. Methods A retrospective study including all consecutive patients who underwent lumbar instrumentation, fusion, and decompression for spondylolisthetic stenosis and degenerative disk disease was conducted between January 2012 and January 2016. All operations were performed by the same surgeon; the patients were divided into three groups acc…

musculoskeletal diseasesAdultMalemedicine.medical_specialtyPercutaneousDecompressionIntervertebral Disc DegenerationSurgical planningNeurosurgical ProceduresZygapophyseal JointFacet joint03 medical and health sciences0302 clinical medicineLumbarSpinal StenosisPedicle ScrewsRisk FactorsmedicineHumansInstrumentation (computer programming)AgedRetrospective Studies030222 orthopedicsLumbar Vertebraebusiness.industryRetrospective cohort studyMiddle Agedmusculoskeletal systemmedicine.diseaseSurgeryStenosismedicine.anatomical_structureSpinal FusionTreatment OutcomeSurgeryFemaleNeurology (clinical)business030217 neurology & neurosurgeryJournal of neurological surgery. Part A, Central European neurosurgery
researchProduct

Biomechanical testing of different posterior fusion devices on lumbar spinal range of motion.

2019

Abstract Background Recent minimal-invasive posterior fusion devices are supposed to provide stability and obtain fusion in combination with interbody cages in the instrumented segment. The aim of the present study is to evaluate the primary stability of two minimal-invasive posterior prototypes compared to an established spinous process plate and standard pedicle screw instrumentation. Methods Seven fresh frozen human cadaver lumbar spines (L2–L5) were tested in a spinal testing device with a moment of 7.5 Nm. Spinal stability was determined as mean range of motion (RoM) in the segment L3/L4 during extension-flexion, lateral bending and axial rotation. The RoM was measured during five cond…

musculoskeletal diseasesFacet (geometry)Materials scienceRotationBiophysics03 medical and health sciencesFixation (surgical)0302 clinical medicineLumbarCadaverBone platemedicineCadaverHumansOrthopedics and Sports MedicineRange of Motion ArticularLumbar VertebraeBiomechanicsLumbosacral RegionLumbar spinal stenosis030229 sport sciencesmusculoskeletal systemmedicine.diseaseBiomechanical PhenomenaSpinal FusionRange of motionBone Plates030217 neurology & neurosurgeryBiomedical engineeringClinical biomechanics (Bristol, Avon)
researchProduct

The Impact of Single-Level ACDF on Neural Foramen and Disc Height of Surgical and Adjacent Cervical Segments: A Case-Series Radiological Analysis

2023

Background: ACDF has become one of the established procedures for the surgical treatment of symptomatic cervical spondylosis, showing excellent clinical results and effective improvements in neural functions and neck pain relief. The main purpose of ACDF is neural decompression, and it is considered by some authors as an indirect result of the intervertebral distraction and cage insertion and the consequent restoration of the disc space and foramen height. Methods: Radiological data from 28 patients who underwent single-level ACDF were retrospectively collected and evaluated. For neural foramen evaluation, antero-posterior (A-P) and cranio-caudal (C-C) diameters were manually calculated; fo…

neural decompressioncervical spondylosiSettore MED/27 - NeurochirurgiaGeneral Neuroscienceforaminal stenosiintervertebral distractioncervical cagecervical foramenforamen heightACDFACDF; cervical foramen; foramen height; cervical spondylosis; foraminal stenosis; cervical cage; intervertebral distraction; neural decompressionSettore MED/01 - Statistica MedicaBrain Sciences; Volume 13; Issue 1; Pages: 101
researchProduct

Mid-term and late results of endovascular treatment for symptomatic carotid artery stenosis under proximal protection

2021

Introduction: Although filters are still preferred during carotid stenting, proximal protection systems (PPS) are increasingly used during these procedures. PPS seem to be safer than distal systems, especially in symptomatic patients, but evidence supporting their use is limited. Aim: This was a post hoc survey with 30-day mid-term and long-term follow up, which was aimed at assessment of the safety and efficacy of stenting of the internal carotid artery under PPS in symptomatic patients. Material and methods: We analysed the results of stenting in 120 symptomatic patients presenting with at least 60% stenosis. Patients were aged 67.9 ±9.8 years, and 12 patients were older than 80 years. An…

proximal protectionmedicine.medical_specialtyUrologymedicine.medical_treatmentstenting030204 cardiovascular system & hematologyAsymptomatic03 medical and health sciences0302 clinical medicinemedicine.arteryOcclusionClinical endpointMedicineStrokeEndarterectomyOriginal Paperbusiness.industryRGastroenterologyObstetrics and Gynecologymedicine.diseasestrokeSurgeryStenosisMedicinecarotid stenosisSurgeryInternal carotid arteryCarotid stentingmedicine.symptombusiness030217 neurology & neurosurgeryVideosurgery and Other Miniinvasive Techniques
researchProduct

Lumbar facet joint stabilization for symptomatic spinal degenerative disease: A systematic review of the literature

2022

Objective: Lumbar spinal degenerative disease (LSDD), unresponsive to conservative therapy, is commonly treated by surgical decompression and interbody fusion. Since facet joint incompetence has been suggested as responsible for the entire phenomenon of spinal degeneration, facet stabilization can be considered as an alternative technique to treat symptomatic spinal degenerative disease. The purpose of this study was to systematically review the literature for studies utilizing lumbar facet joint fixation techniques for LSDD to assess their safety and efficacy. Methods: A systematic literature review was performed following the preferred reporting items for systematic reviews and meta-analy…

spinal stenosilumbar spinal degenerative diseaseSurgeryNeurology (clinical)Facet fixationneurogenic intermittent claudication
researchProduct

Remodeling Pattern of Spinal Canal after Full Endoscopic Uniportal Lumbar Endoscopic Unilateral Laminotomy for Bilateral Decompression: One Year Repe…

2022

Objective: There is limited literature on repetitive postoperative MRI and clinical evaluation after Uniportal Lumbar Endoscopic Unilateral Laminotomy for Bilateral Decompression. Methods: Clinical visual analog scale, Oswestry Disability Index, McNab’s criteria evaluation and MRI evaluation of the axial cut spinal canal area of the upper end plate, mid disc and lower end plate were performed for patients who underwent single-level Uniportal Lumbar Endoscopic Unilateral Laminotomy for Bilateral Decompression. From the evaluation of the axial cut MRI, four types of patterns of remodeling were identified: type A: continuous expanded spinal canal, type B: restenosis with delayed expansio…

spinal stenosisendoscopic spine surgeryClinical Biochemistrydegenerative spine diseaseminimally invasive spine surgeryendoscopic spine surgery; lumbar endoscopic unilateral laminotomy with bilateral decompression; degenerative spine disease; spinal stenosis; remodeling of spine; minimally invasive spine surgerylumbar endoscopic unilateral laminotomy with bilateral decompressionremodeling of spineDiagnostics; Volume 12; Issue 4; Pages: 793
researchProduct