Search results for " tomography"

showing 10 items of 1487 documents

Comparison of 99mTc-Labeled Colloid SPECT/CT and Planar Lymphoscintigraphy in Sentinel Lymph Node Detection in Patients with Melanoma: A Meta-Analysis

2020

We compared the detection rate (DR) for sentinel lymph nodes (SLNS), the number of SLNs and the subjects with additional SLNs of single-photon emission computed tomography (SPECT/CT) and planar lymphoscintigraphy (PL) in patients with melanoma. Furthermore, we evaluated the impact of SPECT/CT on surgical plans. Articles containing head-to-head comparisons between SPECT/CT and PL were searched in Pubmed/MEDLINE and Scopus. The literature search was updated until December 31st, 2019. DR was calculated on a per-patient-based analysis; the studies were pooled by their odds ratios (ORs) with a random effects model to assess the significance of difference (p < 0.05). The number of additional S…

planar lymphoscintigraphySentinel lymph nodelcsh:MedicineSingle-photon emission computed tomography030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicinesentinel lymph node99mTc-labeled colloidsmedicinemelanomamedicine.diagnostic_testbusiness.industryMelanomalcsh:RGeneral MedicineOdds ratiomedicine.diseaseConfidence intervalbody regionsmeta-analysis<sup>99m</sup>Tc-labeled colloids030220 oncology & carcinogenesisRelative riskMeta-analysis99mTc-labeled colloids; melanoma; meta-analysis; planar lymphoscintigraphy; sentinel lymph node; single photon emission/computed tomographysingle photon emission/computed tomographyNuclear medicinebusinessEmission computed tomographyJournal of Clinical Medicine
researchProduct

Effects of pyrolysis temperature on the hydrologically relevant porosity of willow biochar

2018

Biochar pore space consists of porosity of multiple length scales. In direct water holding applications like water storage for plant water uptake, the main interest is in micrometre-range porosity since these pores are able to store water that is easily available for plants. Gas adsorption measurements which are commonly used to characterize the physical pore structure of biochars are not able to quantify this pore-size range. While pyrogenetic porosity (i.e. pores formed during pyrolysis process) tends to increase with elevated process temperature, it is uncertain whether this change affects the pore space capable to store plant available water. In this study, we characterized biochar poro…

porosityMaterials scienceFOS: Physical sciencesApplied Physics (physics.app-ph)010501 environmental sciencesRaw materialkuivatislaus01 natural sciencesAnalytical ChemistryhuokoisuusAdsorptionimage analysisBiocharmedicinebiocharta216CharcoalPorosityta2180105 earth and related environmental sciencesCondensed Matter - Materials Sciencex-ray tomographybiohiilita114Materials Science (cond-mat.mtrl-sci)Physics - Applied Physics04 agricultural and veterinary sciencesAtmospheric temperature rangeslow pyrolysisWater retentionFuel TechnologykuvantaminenChemical engineeringvisual_artkuva-analyysi040103 agronomy & agriculturevisual_art.visual_art_medium0401 agriculture forestry and fisheriesmedicine.symptomPyrolysis
researchProduct

Inter-crystal scatter in positron emission tomography: Identification techniques and effects on reconstructed images for AX-PET demonstrator

2012

La PET es una técnica de imagen en medicina nuclear que permite la visualización in-vivo y en 3D de procesos funcionales en seres vivos. Un escáner PET mide los rayos gamma producidos al aniquilarse un positrón, el cual es emitido por un radioisótopo inyectado al paciente. La eficiencia del sistema es una característica crucial de los escáneres PET de alta resolución dedicados a la imagen del cerebro o de animales pequeños con el fin de obtener una imagen más fiel o de reducir la actividad del radiotrazador, y por consiguiente, la dosis inyectada al paciente. El objetivo de este trabajo de investigación es mejorar la eficiencia y calidad de imagen de un prototipo de escáner PET axial (AX-PE…

positron emission tomographyCompton effectUNESCO::CIENCIAS MÉDICASaxial PETbayesianUNESCO::FÍSICAinter-crystal scatter
researchProduct

Radiolabeling of Nanoparticles and Polymers for PET Imaging

2014

Nanomedicine has become an emerging field in imaging and therapy of malignancies. Nanodimensional drug delivery systems have already been used in the clinic, as carriers for sensitive chemotherapeutics or highly toxic substances. In addition, those nanodimensional structures are further able to carry and deliver radionuclides. In the development process, non-invasive imaging by means of positron emission tomography (PET) represents an ideal tool for investigations of pharmacological profiles and to find the optimal nanodimensional architecture of the aimed-at drug delivery system. Furthermore, in a personalized therapy approach, molecular imaging modalities are essential for patient screeni…

radiolabelingmedicine.medical_specialtyPharmaceutical ScienceNanoparticlelcsh:Medicinelcsh:RS1-441NanotechnologyReviewlcsh:Pharmacy and materia medicaDrug DiscoverymedicineMedical physicsPersonalized therapypolymersmedicine.diagnostic_testbusiness.industrylcsh:RPositron emittersimagingPet imagingnanomedicinepositron emitterPETPositron emission tomographyDrug deliverydrug deliveryMolecular MedicineNanomedicinenanoparticlesMolecular imagingbusinessPharmaceuticals
researchProduct

Retinal Vascular Assessment in Psoriasis: A Multicenter Study

2021

PurposeTo investigate the vascular status of the macula in psoriasis patients without history of ocular inflammation by Optical Coherence Tomography Angiography (OCTA).MethodsThis prospective cross-sectional multicenter study included 55 psoriasis patients and 55 control healthy subjects. A complete eye examination and 6 mm × 6 mm OCTA imaging were performed. Retinal vascular status was evaluated by analyzing vascular density (VD) of superficial vascular plexus (superficial wVD) and deep vascular plexuses (deep wVD) in a 6 mm × 6 mm area and in foveal (superficial fVD and deep fVD) and parafoveal sectors (superficial pVD and deep pVD). In addition, foveal thickness (FT) and foveal avascular…

retinaIntraocular pressuremedicine.medical_specialtyvascular changesgenetic structuresmacula; optical coherence tomography angiography; psoriasis; retina; vascular changesoptical coherence tomography angiographylcsh:RC321-571030207 dermatology & venereal diseases03 medical and health scienceschemistry.chemical_compoundPsoriatic arthritis0302 clinical medicineOphthalmologyPsoriasisMedicinemaculalcsh:Neurosciences. Biological psychiatry. NeuropsychiatrypsoriasiOriginal ResearchRetinamedicine.diagnostic_testbusiness.industryGeneral NeuroscienceRetinalpsoriasisOptical coherence tomography angiographymedicine.diseaseeye diseasesmedicine.anatomical_structurechemistryMulticenter studyEye examination030221 ophthalmology & optometrysense organsbusinessNeuroscienceFrontiers in Neuroscience
researchProduct

Retinal abnormalities in multiple sclerosis patients with associated chronic cerebrospinal venous insufficiency

2012

Optical coherence tomography (OCT) is a non-invasive method for the assessment of optic nerve fibers and retinal ganglion cells. This study was aimed at the assessment of retinal abnormalities in multiple sclerosis patients in the context of chronic cerebrospinal venous insufficiency using OCT of the retina and the optic nerve. We examined 239 multiple sclerosis (MS) patients, including 220 patients with associated chronic cerebrospinal venous insufficiency and 19 MS patients without venous pathology. The following OCT parameters were assessed: average ganglion cell complex thickness, global loss volume, focal loss volume and average retinal nerve fibre layer thickness. Abnormalities in the…

retinalcsh:Diseases of the circulatory (Cardiovascular) systemmedicine.medical_specialtyPathologygenetic structuresVenographymultiple sclerosisRetinal ganglionoptic nervemultiple sclerosis optic nerve optical coherence tomography retina venous insufficiency.Ophthalmologyvenous insufficiencymedicineOptic neuritisInternal jugular veinRetinaoptical coherence tomographymedicine.diagnostic_testbusiness.industryMultiple sclerosismedicine.diseaseeye diseasesChronic cerebrospinal venous insufficiencymedicine.anatomical_structurelcsh:RC666-701Optic nervesense organsbusinessVeins and Lymphatics
researchProduct

Macular Structure–Function Relationships of All Retinal Layers in Primary Open-Angle Glaucoma Assessed by Microperimetry and 8 × 8 Posterior Pole Ana…

2021

Purpose: The aim of this study is too correlate the sensitivity and thickness values of intraretinal layers at macula in healthy eyes and primary open-angle glaucoma (POAG) eyes. Methods: The thickness of different intraretinal segmentations was estimated by means of optical coherence tomography (OCT) Spectralis (Heidelberg, Engineering, Inc., Heidelberg, Germany) with the posterior pole analysis program 8 × 8 in 91 eyes from 91 patients (60 with glaucoma and 31 healthy patients). Macular sensitivity was also measured with an MP-1 microperimeter (Nidek Instruments, Inc Padova, Italy) with a customized, 36-stimulus pattern adjusted to an anatomical correspondence with the OCT grid. Correlati…

retinamedicine.medical_specialtygenetic structuresOpen angle glaucomainnerPosterior poleGlaucomaArticlechemistry.chemical_compoundouterOptical coherence tomographyOphthalmologyMedicinemaculastructurefunctionRetinamedicine.diagnostic_testbusiness.industryRRetinalGeneral Medicinemedicine.diseaseeye diseasesglaucomamedicine.anatomical_structureOCTchemistrycorrelationInner nuclear layermicroperimetryMedicinesense organsbusinessMicroperimetryJournal of Clinical Medicine
researchProduct

Intravenous Contrast Material for Cardiac Computed Tomography

2023

Purpose: The Italian Registry of Contrast Material use in Cardiac Computed Tomography (iRCM-CCT) is a multicenter, multivendor, observational study on the use of contrast media (CM) in patients undergoing cardiac computed tomography (CCT). The aim of iRCM-CCT is to assess image quality and safety profile of intravenous CM compounds. Materials and methods: iRCM-CCT enrolled 1842 consecutive patients undergoing CCT (≥50 per site) at 20 cluster sites with the indication of suspected coronary artery disease. Demographic characteristics, CCT, and CM protocols, clinical indications, safety markers, radiation dose reports, qualitative (ie, poor vascular enhancement) and quantitative (ie, HU attenu…

safetyPulmonary and Respiratory MedicineSettore MED/36 - Diagnostica per Immagini e Radioterapiacoronary arteriecomputed tomography angiography; contrast media; coronary arteries; image enhancement; safetyRadiology Nuclear Medicine and imagingcomputed tomography angiography; contrast media; coronary arteries; image enhancement; safety;image enhancementcontrast mediacomputed tomography angiographycoronary arteriesimage enhancement contrast media safetycomputed tomography angiographycoronary arteriesimage enhancementcontrast mediasafetyJournal of Thoracic Imaging
researchProduct

Analysis of microtomographic images of porous heterogeneous materials

2015

In this work, we study the phases of image processing chain of microtomographic imag- ing in order to obtain reliable results while optimizing the time spent on denoising and segmentation. We consider that the decisions made at the early phases of the processing chain are most important and the selection made there essentially determine the overall quality of imaging process. We also compare here various denoising method qualita- tively, however, we think that the pure noise removal ability is not the only requirement for noise removal in microtomographic images. By proper denoising we can affect selec- tion of segmentation methods and, thus, also the quality of the analysis. Additionally, …

segmentationröntgentutkimuskuvankäsittelysegmentointimateriaalitutkimushuokoisuuskuvantaminenimage analysistomografiadenoising3D image processing3D-mallinnuskohinaX-ray tomography
researchProduct

Microchimerism and multiple sclerosis: a study on the impact of the sex of offspring on clinical, radiological, and paraclinical features of maternal…

2023

Background. Multiple sclerosis (MS) is a chronic autoimmune disorder characterised by inflammation and neurodegeneration and representing one of the most common causes of neurologic disability among young adults. Over the last 40 years, several authors have confirmed the existence of fetal cells in maternal blood and their pregnancy-related origin, demonstrating that pregnancy may establish a long-term, low-grade chimeric state in women. The biological and clinical significance of fetal microchimeric cells (fMCs) in maternal health is largely unknown, although a role in autoimmune diseases have been hypothesised. Aims. The overarching aim of my PhD dissertation was to investigate the role o…

sex of offspringmultiple sclerosimicrochimerismmagnetic resonance imagingpregnancysexual chromosomeoptic coherence tomography
researchProduct