Search results for " tomography"
showing 10 items of 1487 documents
Comparison of 99mTc-Labeled Colloid SPECT/CT and Planar Lymphoscintigraphy in Sentinel Lymph Node Detection in Patients with Melanoma: A Meta-Analysis
2020
We compared the detection rate (DR) for sentinel lymph nodes (SLNS), the number of SLNs and the subjects with additional SLNs of single-photon emission computed tomography (SPECT/CT) and planar lymphoscintigraphy (PL) in patients with melanoma. Furthermore, we evaluated the impact of SPECT/CT on surgical plans. Articles containing head-to-head comparisons between SPECT/CT and PL were searched in Pubmed/MEDLINE and Scopus. The literature search was updated until December 31st, 2019. DR was calculated on a per-patient-based analysis; the studies were pooled by their odds ratios (ORs) with a random effects model to assess the significance of difference (p < 0.05). The number of additional S…
Effects of pyrolysis temperature on the hydrologically relevant porosity of willow biochar
2018
Biochar pore space consists of porosity of multiple length scales. In direct water holding applications like water storage for plant water uptake, the main interest is in micrometre-range porosity since these pores are able to store water that is easily available for plants. Gas adsorption measurements which are commonly used to characterize the physical pore structure of biochars are not able to quantify this pore-size range. While pyrogenetic porosity (i.e. pores formed during pyrolysis process) tends to increase with elevated process temperature, it is uncertain whether this change affects the pore space capable to store plant available water. In this study, we characterized biochar poro…
Inter-crystal scatter in positron emission tomography: Identification techniques and effects on reconstructed images for AX-PET demonstrator
2012
La PET es una técnica de imagen en medicina nuclear que permite la visualización in-vivo y en 3D de procesos funcionales en seres vivos. Un escáner PET mide los rayos gamma producidos al aniquilarse un positrón, el cual es emitido por un radioisótopo inyectado al paciente. La eficiencia del sistema es una característica crucial de los escáneres PET de alta resolución dedicados a la imagen del cerebro o de animales pequeños con el fin de obtener una imagen más fiel o de reducir la actividad del radiotrazador, y por consiguiente, la dosis inyectada al paciente. El objetivo de este trabajo de investigación es mejorar la eficiencia y calidad de imagen de un prototipo de escáner PET axial (AX-PE…
Radiolabeling of Nanoparticles and Polymers for PET Imaging
2014
Nanomedicine has become an emerging field in imaging and therapy of malignancies. Nanodimensional drug delivery systems have already been used in the clinic, as carriers for sensitive chemotherapeutics or highly toxic substances. In addition, those nanodimensional structures are further able to carry and deliver radionuclides. In the development process, non-invasive imaging by means of positron emission tomography (PET) represents an ideal tool for investigations of pharmacological profiles and to find the optimal nanodimensional architecture of the aimed-at drug delivery system. Furthermore, in a personalized therapy approach, molecular imaging modalities are essential for patient screeni…
Retinal Vascular Assessment in Psoriasis: A Multicenter Study
2021
PurposeTo investigate the vascular status of the macula in psoriasis patients without history of ocular inflammation by Optical Coherence Tomography Angiography (OCTA).MethodsThis prospective cross-sectional multicenter study included 55 psoriasis patients and 55 control healthy subjects. A complete eye examination and 6 mm × 6 mm OCTA imaging were performed. Retinal vascular status was evaluated by analyzing vascular density (VD) of superficial vascular plexus (superficial wVD) and deep vascular plexuses (deep wVD) in a 6 mm × 6 mm area and in foveal (superficial fVD and deep fVD) and parafoveal sectors (superficial pVD and deep pVD). In addition, foveal thickness (FT) and foveal avascular…
Retinal abnormalities in multiple sclerosis patients with associated chronic cerebrospinal venous insufficiency
2012
Optical coherence tomography (OCT) is a non-invasive method for the assessment of optic nerve fibers and retinal ganglion cells. This study was aimed at the assessment of retinal abnormalities in multiple sclerosis patients in the context of chronic cerebrospinal venous insufficiency using OCT of the retina and the optic nerve. We examined 239 multiple sclerosis (MS) patients, including 220 patients with associated chronic cerebrospinal venous insufficiency and 19 MS patients without venous pathology. The following OCT parameters were assessed: average ganglion cell complex thickness, global loss volume, focal loss volume and average retinal nerve fibre layer thickness. Abnormalities in the…
Macular Structure–Function Relationships of All Retinal Layers in Primary Open-Angle Glaucoma Assessed by Microperimetry and 8 × 8 Posterior Pole Ana…
2021
Purpose: The aim of this study is too correlate the sensitivity and thickness values of intraretinal layers at macula in healthy eyes and primary open-angle glaucoma (POAG) eyes. Methods: The thickness of different intraretinal segmentations was estimated by means of optical coherence tomography (OCT) Spectralis (Heidelberg, Engineering, Inc., Heidelberg, Germany) with the posterior pole analysis program 8 × 8 in 91 eyes from 91 patients (60 with glaucoma and 31 healthy patients). Macular sensitivity was also measured with an MP-1 microperimeter (Nidek Instruments, Inc Padova, Italy) with a customized, 36-stimulus pattern adjusted to an anatomical correspondence with the OCT grid. Correlati…
Intravenous Contrast Material for Cardiac Computed Tomography
2023
Purpose: The Italian Registry of Contrast Material use in Cardiac Computed Tomography (iRCM-CCT) is a multicenter, multivendor, observational study on the use of contrast media (CM) in patients undergoing cardiac computed tomography (CCT). The aim of iRCM-CCT is to assess image quality and safety profile of intravenous CM compounds. Materials and methods: iRCM-CCT enrolled 1842 consecutive patients undergoing CCT (≥50 per site) at 20 cluster sites with the indication of suspected coronary artery disease. Demographic characteristics, CCT, and CM protocols, clinical indications, safety markers, radiation dose reports, qualitative (ie, poor vascular enhancement) and quantitative (ie, HU attenu…
Analysis of microtomographic images of porous heterogeneous materials
2015
In this work, we study the phases of image processing chain of microtomographic imag- ing in order to obtain reliable results while optimizing the time spent on denoising and segmentation. We consider that the decisions made at the early phases of the processing chain are most important and the selection made there essentially determine the overall quality of imaging process. We also compare here various denoising method qualita- tively, however, we think that the pure noise removal ability is not the only requirement for noise removal in microtomographic images. By proper denoising we can affect selec- tion of segmentation methods and, thus, also the quality of the analysis. Additionally, …
Microchimerism and multiple sclerosis: a study on the impact of the sex of offspring on clinical, radiological, and paraclinical features of maternal…
2023
Background. Multiple sclerosis (MS) is a chronic autoimmune disorder characterised by inflammation and neurodegeneration and representing one of the most common causes of neurologic disability among young adults. Over the last 40 years, several authors have confirmed the existence of fetal cells in maternal blood and their pregnancy-related origin, demonstrating that pregnancy may establish a long-term, low-grade chimeric state in women. The biological and clinical significance of fetal microchimeric cells (fMCs) in maternal health is largely unknown, although a role in autoimmune diseases have been hypothesised. Aims. The overarching aim of my PhD dissertation was to investigate the role o…