Search results for " view"

showing 10 items of 337 documents

OCTOCAM: A fast multichannel imager and spectrograph for the 10.4m GTC

2010

OCTOCAM is a multi-channel imager and spectrograph that has been proposed for the 10.4m GTC telescope. It will use dichroics to split the incoming light to produce simultaneous observations in 8 different bands, ranging from the ultraviolet to the near-infrared. The imaging mode will have a field of view of 2' x 2' in u, g, r, i, z, J, H and Ks bands, whereas the long-slit spectroscopic mode will cover the complete range from 4,000 to 23,000 {\AA} with a resolution of 700 - 1,700 (depending on the arm and slit width). An additional mode, using an image slicer, will deliver a spectral resolution of over 3,000. As a further feature, it will use state of the art detectors to reach high readout…

PhysicsGran Telescopio Canariasbusiness.industryResolution (electron density)Near-infrared spectroscopyAstrophysics::Instrumentation and Methods for AstrophysicsFOS: Physical sciencesField of viewlaw.inventionTelescopeOpticslawObservatorySpectral resolutionbusinessAstrophysics - Instrumentation and Methods for AstrophysicsInstrumentation and Methods for Astrophysics (astro-ph.IM)Spectrograph
researchProduct

The European Photon Imaging Camera on XMM-Newton: The MOS Cameras

2000

The EPIC focal plane imaging spectrometers on XMM-Newton use CCDs to record the images and spectra of celestial X-ray sources focused by the three X-ray mirrors. There is one camera at the focus of each mirror; two of the cameras contain seven MOS CCDs, while the third uses twelve PN CCDs, defining a circular field of view of 30 arcmin diameter in each case. The CCDs were specially developed for EPIC, and combine high quality imaging with spectral resolution close to the Fano limit. A filter wheel carrying three kinds of X-ray transparent light blocking filter, a fully closed, and a fully open position, is fitted to each EPIC instrument. The CCDs are cooled passively and are under full clos…

PhysicsInstrumentation: detectorPhotonSpectrometerbusiness.industryDynamic rangeAstrophysics::High Energy Astrophysical PhenomenaAstrophysics (astro-ph)Astrophysics::Instrumentation and Methods for AstrophysicsFOS: Physical sciencesAstronomy and AstrophysicsField of viewAstrophysicsAstrophysicsX-rays: generalOpticsCardinal pointSpace and Planetary ScienceCalibrationSpectral resolutionbusinessFocus (optics)
researchProduct

JEM–X: The X-ray monitor aboard INTEGRAL

2003

The JEM-X monitor provides X-ray spectra and imaging with arcminute angular resolution in the 3 to 35 keV band. The good angular resolution and the low energy response of JEM-X plays an important role in the identification of gamma ray sources and in the analysis and scientific interpretation of the combined X-ray and gamma ray data. JEM-X is a coded aperture instrument consisting of two identical, coaligned telescopes. Each of the detectors has a sensitive area of 500 cm 2 , and views the sky through its own coded aperture mask. The two coded masks are inverted with respect to each other and provides an angular resolution of 3 0 across an eective field of view of about 10 diameter.

PhysicsInstrumentation: detectors; X-rays: general;010504 meteorology & atmospheric sciencesSpectrometerbusiness.industryAstrophysics::High Energy Astrophysical PhenomenaResolution (electron density)Astrophysics::Instrumentation and Methods for AstrophysicsGamma rayAstronomy and AstrophysicsField of viewCosmic rayAstrophysics01 natural sciencesParticle detectorOpticsSpace and Planetary Science0103 physical sciencesAngular resolutionCoded aperturebusiness010303 astronomy & astrophysics0105 earth and related environmental sciencesAstronomy & Astrophysics
researchProduct

Optical module for single-shot quantitative phase imaging based on the transport of intensity equation with field of view multiplexing

2021

We present a cost-effective, simple, and robust method that enables single-shot quantitative phase imaging (QPI) based on the transport of intensity equation (TIE) using an add-on optical module that can be assembled into the exit port of any regular microscope. The module integrates a beamsplitter (BS) cube (placed in a non-conventional way) for duplicating the output image onto the digital sensor (field of view – FOV – multiplexing), a Stokes lens (SL) for astigmatism compensation (introduced by the BS cube), and an optical quality glass plate over one of the FOV halves for defocusing generation (needed for single-shot TIE algorithm). Altogether, the system provides two laterally separate…

PhysicsMicroscopeImage qualitybusiness.industryComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONPhase (waves)Field of viewÒpticaOptometriaMultiplexingAtomic and Molecular Physics and Opticslaw.inventionLens (optics)OpticslawbusinessPhase retrievalBeam splitter
researchProduct

2017

Micro-fluidic pumps as well as artificial micro-swimmers are conveniently realized exploiting phoretic solvent flows based on local gradients of temperature, electrolyte concentration or pH. We here present a facile micro-photometric method for monitoring pH gradients and demonstrate its performance and scope on different experimental situations including an electro-osmotic pump and modular micro-swimmers assembled from ion exchange resin beads and polystyrene colloids. In combination with the present microscope and DSLR camera our method offers a 2 \mu m spatial resolution at video frame rate over a field of view of 3920x2602 \mu m^2. Under optimal conditions we achieve a pH-resolution of …

PhysicsMicroscopebusiness.industryMicrofluidicsGeneral Physics and AstronomyField of view02 engineering and technologyElectrolyteModular design010402 general chemistry021001 nanoscience & nanotechnologyFrame rate01 natural sciences0104 chemical scienceslaw.inventionCharacterization (materials science)law0210 nano-technologyBiological systembusinessImage resolutionNew Journal of Physics
researchProduct

AX-PET: A novel PET concept with G-APD readout

2012

Abstract The AX-PET collaboration has developed a novel concept for high resolution PET imaging to overcome some of the performance limitations of classical PET cameras, in particular the compromise between spatial resolution and sensitivity introduced by the parallax error. The detector consists of an arrangement of long LYSO scintillating crystals axially oriented around the field of view together with arrays of wave length shifter strips orthogonal to the crystals. This matrix allows a precise 3D measurement of the photon interaction point. This is valid both for photoelectric absorption at 511 keV and for Compton scattering down to deposited energies of about 100 keV. Crystals and WLS s…

PhysicsNuclear and High Energy PhysicsPhotonPhysics::Instrumentation and Detectorsbusiness.industryPhysics::Medical PhysicsDetectorCompton scatteringField of viewLyso-030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineOpticsSilicon photomultiplier030220 oncology & carcinogenesisTomographybusinessInstrumentationImage resolutionNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

A device to measure the effects of strong magnetic fields on the image resolution of PET scanners

2009

Abstract Very high resolution images can be achieved in small animal PET systems utilizing solid state silicon pad detectors. As these systems approach sub-millimeter resolutions, the range of the positron is becoming the dominant contribution to image blur. The size of the positron range effect depends on the initial positron energy and hence the radioactive tracer used. For higher energy positron emitters, such as Ga 68 and Tc 94 m , which are gaining importance in small animal studies, the width of the annihilation point distribution dominates the spatial resolution. This positron range effect can be reduced by embedding the field of view of the PET scanner in a strong magnetic field. In…

PhysicsNuclear and High Energy PhysicsRadioactive tracerAnnihilationPhysics::Instrumentation and Detectorsbusiness.industryResolution (electron density)DetectorField of viewlaw.inventionMagnetic fieldOpticsNuclear magnetic resonancePositronlawPhysics::Accelerator PhysicsbusinessInstrumentationImage resolutionNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Preliminary assessment of the imaging capability of the YAP–(S)PET small animal scanner in neuroscience

2006

The new and fully engineered version of the YAP–(S)PET small animal scanner has been tested at the University of Mainz for preliminary assessment of its imaging capability for studies related to neuropharmacology and psychiatry. The main feature of the scanner is the capability to combine PET and SPECT techniques. It allows the development of new and interesting protocols for the investigation of many biological phenomena, more effectively than with PET or SPECT modalities alone. The scanner is made up of four detector heads, each one composed of a 4 � 4c m 2 of YAlO3:Ce (or YAP:Ce) matrix, and has a field of view (FOV) of 4 cm axially � 4c m + transaxially. In PET mode, the volume resoluti…

PhysicsNuclear and High Energy PhysicsScannermedicine.medical_specialtymedicine.diagnostic_testDetectorCollimatorField of viewSingle-photon emission computed tomographylaw.inventionFeature (computer vision)lawPositron emission tomographySmall animalmedicineMedical physicsInstrumentationBiomedical engineeringNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Tests of Lobster Eye Optics for Small Space X-ray Telescope

2011

Abstract The Lobster eye design for a grazing incidence X-ray optics provides wide field of view of the order of many degrees, for this reason it can be a convenient approach for the construction of space all-sky X-ray monitors. We present preliminary results of tests of prototype lobster eye X-ray optics in quasi parallel beam full imaging mode conducted using the 35 m long X-ray beam-line of INAF-OAPA in Palermo (Italy). X-ray images at the focal plane have been taken with a microchannel plate (MCP) detector at several energy values from 0.3 to 8 keV. The gain, the field of view and the angular resolution have been measured and compared with theoretical values.

PhysicsNuclear and High Energy Physicsbusiness.industryAstrophysics::High Energy Astrophysical PhenomenaDetectorX-ray opticsField of viewX-ray telescopeCardinal pointOpticsLobster eye X-ray optics X-ray telescope All-sky monitor X-ray imaging X-raySettore FIS/05 - Astronomia E AstrofisicaAngular resolutionMicrochannel plate detectorbusinessInstrumentationEnergy (signal processing)
researchProduct

Inclination of Large Coronal Loops Observed by TRACE

2000

A TRACE field of view well inside the solar disk shows very well defined large loops, likely to be very inclined to the solar surface. On the other hand there is little evidence of large loops perpendicular to the solar surface. We show that this does not mean that most large loops have such large inclination but that perpendicular loops are much less visible to TRACE, because of density stratification. We quantitatively evaluate this effect by modeling in detail loops with different inclinations.

PhysicsOpticsbusiness.industryPhysics::Space PhysicsPerpendicularAstrophysics::Solar and Stellar AstrophysicsField of viewSolar surfaceAstrophysics::Earth and Planetary AstrophysicsCoronal loopbusinessSolar diskComputational physics
researchProduct