Search results for "010401 analytical chemistry"
showing 10 items of 1284 documents
Time‐gated Raman and laser‐induced breakdown spectroscopy in mapping of eudialyte and catapleiite
2019
Abstract Raman analysis of rock samples containing rare earth elements (REEs) is challenging due to the strong fluorescence, which may mask the weaker Raman signal. In this research, time‐gated (TG) Raman has been applied to the construction of the mineral distribution map from REE‐bearing rock. With TG Raman, material is excited with a short subnanosecond laser pulse, and the Raman signal is collected within a picosecond‐scale time window prior to the formation of a strong fluorescent signal by means of single‐photon avalanche diode array. This allows signal readout with a significantly reduced fluorescence background. TG Raman maps are used to reveal the location of valuable minerals and …
Preliminary results on direct quantitative determination of cocaine in impregnated materials by infrared spectroscopy
2018
Abstract Partial least squares models were built for the direct determination of cocaine in seized impregnated smuggled materials. Measurements are based on the attenuated total reflectance middle infrared spectra (ATR-MIR) and diffuse reflectance spectra in the near range (DR-NIR) obtained directly from the surface of the impregnated materials. The aforementioned procedures offer fast, cheap and environmentally friendly green alternatives to the reference method based on the extraction of the drug and its quantification by gas chromatography. Additionally it has been verified that results found are statistically comparable with those obtained by the reference method with root mean square e…
Materials, Techniques, and Conservation of Historic Stained Glass “Grisailles”
2015
A grisaille is a brown-blackish paint applied onto the inner surface of stained glass to draw the contours and details of the figures and to produce the effect of shades and volumes. Grisailles were traditionally made of finely ground oxides of iron but also of copper, zinc, lead, or manganese mixed with a flux such as lead ground glass and a binder and fixed onto the flat glass by firing. The grisailles have typical layer thickness varying between 10 and 100 µm and are formed by a complex mixture of pigment particles, crystalline, and amorphous reaction compounds, aging, and weathering compounds. The high brilliance, collimation, energy selection, and monochromacity of the SR beam are idea…
Nanosized hydrophobic gels: Advanced supramolecules for use in electrochemical bio- and immunosensing
2018
Abstract Nanosized hydrogels have emerging as versatile supramolecules materials with application in various electrochemical biosensing devices. This review reports a systematic study of the usefulness of nano-sized hydrogels in the different steps of the process of development of electrochemical biosensing systems. The advantages offered by nano-sized hydrogels in detection of analytes are illustrated with representative recent examples that highlight the scientific interest in widening the use of hydrogel nanoparticles in electrochemical biosensing methods. In this review, different types of hydrogel nanoparticles-based electrochemical biosensors, such as enzyme, protein, and nucleic acid…
Dielectric spectroscopy as a potential technique for prediction of kiwifruit quality indices during storage
2019
Dielectric spectroscopy has been employed as a simple, low cost and a non-destructive way for prediction of some physicochemical indices of kiwifruit during storage. A parallel-plate capacitor was developed and supplied with sinusoidal voltage waves within a frequency range of 40 kHz – 20 MHz. Dielectric properties of samples were measured by the dielectric sensor. Additionally, changes associated with fruit ripening properties, including firmness, total soluble solid (TSS) and pH were determined as a function of time at 2 °C. The results showed that storage time significantly affected the quality characteristics of kiwifruit. Artificial neural networks (ANNs) were employed to develop model…
On Energy Harvesting Using Piezoelectric Transducer with Two-Port Model Under Force Excitation
2019
Piezoelectric (PE) materials are functional materials that can be used for transforming mechanical stress into electrical energy, that can then be stored and used for powering other devices. In this paper, we provide experimental investigation of PE transducers used for energy harvesting under external force-controlled excitation. The lumped parameter electromechanical model (LPEM) has been assumed and brought into a generalized two-port network notation. Laboratory experiments using a universal test machine (UTM) were performed and used for the parameter identification of the model. The two-port model formulation is validated by comparing results of numerical simulations and experimental d…
The methane Raman spectrum from 1200 to 5500 cm(-1): A first step toward temperature diagnostic using methane as a probe molecule in combustion syste…
2005
International audience; We present a study of the spontaneous Raman spectra of (CH4)-C-12 from 1200 to 5500 cm(-1) at various temperatures. This study is of interest from a fundamental as well as from a practical point of view with regards to the temperature diagnostic in hydrocarbon combustion. The present investigation shows that the spontaneous (CH4)-C-12 Raman spectra are very sensitive to temperature and that the complexity of methane spectra is not an obstacle to use methane as a probe molecule in laser-diagnostic techniques. Our study consists in determining the polarisability parameters of methane (CH4)-C-12, unknown at the present time, from spontaneous Raman spectra recorded at pr…
Benzene monitoring by micro-machined sensors with SnO2 layer obtained by using micro-droplet deposition technique
2011
International audience; SnO2 thin layers were deposited by the way of the micro-droplet technique. The sensor substrate consisted of a thin membrane developed on oxidised silicon wafer. The sensing layers were deposited by means of the micro-droplet technique into thin layers of about 100 nm. Such devices were tested for benzene detection. The obtained results showed a very high sensitivity for this chemical compound since 500 ppb were detected. The results presented in this paper were not focused on the reactional mechanism of benzene detection but rather on the development of a cheap and sensitive sensor using sol-gel and micro-droplet processes. Since these layers were elaborated using s…
Water solubility in trachytic and pantelleritic melts: an experimental study
2021
International audience; Solubility experiments were performed on a trachyte and a pantellerite from Pantelleria. The trachyte has SiO 2 = 65.2 wt%, Al 2 O 3 = 15.2 wt% and a peralkaline index (P.I. = molar[(Na 2 O + K 2 O)/Al 2 O 3 ]) ∼ 1 while the pantellerite has SiO 2 = 72.2 wt%, Al 2 O 3 = 11 wt% and a P.I. = 1.3. Solubility experiments were performed in the pressure range of 50-300 MPa at T = 950°C for the trachyte and 50-200 MPa at T = 850°C for the pantellerite. The water content of experimental glasses was determined by Karl Fischer titration, elemental analyser and FT-IR spectroscopy. Water content appears similar in both compositions for analogous pressure conditions, varying from…
Innovations in Extractive Phases for In-Tube Solid-Phase Microextraction Coupled to Miniaturized Liquid Chromatography: A Critical Review
2020
Over the past years, a great effort has been devoted to the development of new sorbents that can be used to pack or to coat extractive capillaries for in-tube solid-phase microextraction (IT-SPME). Many of those efforts have been focused on the preparation of capillaries for miniaturized liquid chromatography (LC) due to the reduced availability of capillary columns with appropriate dimensions for this kind of system. Moreover, many of the extractive capillaries that have been used for IT-SPME so far are segments of open columns from the gas chromatography (GC) field, but the phase nature and dimensions are very limited. In particular, polar compounds barely interact with stationary GC phas…