Search results for "030206 dentistry"
showing 10 items of 1721 documents
Reduction rate by decompression as a treatment of odontogenic cysts
2017
Background: Odontogenic cysts are defined as those cysts that arise from odontogenic epithelium and occur in the tooth-bearing regions of the jaws. Cystectomy, marsupialization or decompression of odontogenic cyst are treatment approach to this pathology. The aim of this study was to evaluate the effectiveness of the decompression as the primary treatment of the cystic lesions of the jaws and them reduction rates involving different factors. Material and Methods: 23 patients with odontogenic cysts of the jaws, previously diagnosed by anatomical histopathology (follicular cysts (7) and radicular cysts (16)) underwent decompression as an initial treatment. Clinical examination and pre and pos…
Computed tomography assessment of temporomandibular joint position and dimensions in patients with class II division 1 and division 2 malocclusions
2016
Background This study aimed to investigate and compare the positions and dimensions of the temporomandibular joint and its components, respectively, in patients with Class II division 1 and division 2 malocclusions. Material and methods Computed tomography images of 14 patients with Class II division 1 and 14 patients with Class II division 2 malocclusion were included with a mean age of 11.4 ± 1.2 years. The following temporomandibular joint measurements were made with OsiriX medical imaging software program. From the sagittal images, the anterior, superior, and posterior joint spaces and the mandibular fossa depths were measured. From the axial images, the greatest anteroposterior and med…
In vitro comparison of the efficacy of two fractured implant-prosthesis screw extraction methods: Conventional versus mechanical.
2019
Abstract Statement of problem Implant-supported prostheses may be subject to esthetic, biological, or mechanical complications. Protocols for dealing with these mechanical problems are sparse. Purpose The purpose of this in vitro study was to compare the efficacy of a mechanical system for extracting fractured implant-prosthesis screws with the conventional method. Material and methods A total of 60 screws were divided into 2 groups according to their morphology (flat screws with a smooth shaft and threaded apical area and screws with a completely threaded body) and subjected to fatiguing and static load testing until fracture. The specimens were assigned to 3 operators with varying levels …
Case series of fluoroscopic findings and 3D reconstruction of human spinal MRIs of the space of Okada.
2020
Objective To better understand the unexpected spread of contrast medium observed by conventional fluoroscopic X-ray images during standard neuraxial techniques used in the treatment of pain. The support of 3D reconstruction of MRI images of structures within the lumbar spine was used to better understand the space of Okada. Methods Lumbar facet joint and epidural corticosteroid injections in five patients under fluoroscopic guidance with loss of resistance to air or saline to identify the facet joints or epidural space. Next, in a retrospective study, the authors examined the retrodural space of Okada and the neighboring tissues with 3D reconstruction of spinal MRIs of seven patients withou…
Evaluation of the osteoclastogenic process associated with RANK / RANK-L / OPG in odontogenic myxomas
2018
Background Odontogenic myxoma (OM) is a benign intraosseous neoplasm that exhibits local aggressiveness and high recurrence rates. Osteoclastogenesis is an important phenomenon in the tumor growth of maxillary neoplasms. RANK (Receptor Activator of Nuclear Factor κappa B) is the signaling receptor of RANK-L (Receptor activator of nuclear factor kappa-Β ligand) that activates the osteoclasts. OPG (osteoprotegerin) is a decoy receptor for RANK-L that inhibits pro-osteoclastogenesis. The RANK / RANKL / OPG system participates in the regulation of osteolytic activity under normal conditions, and its alteration has been associated with greater bone destruction, and also with tumor growth. Object…
Comparison of frictional resistance between passive self-ligating brackets and slide-type low-friction ligature brackets during the alignment and lev…
2019
Background To compare the frictional resistance between passive self-ligating brackets and conventional brackets with low-friction ligature under bracket/archwire and root/bone interface during dental alignment and leveling. Material and methods A tridimensional model of the maxilla and teeth of a patient treated with conventional brackets, and slide ligatures was generated employing the SolidWorks modeling software. SmartClip self-ligating brackets and Logic Line conventional brackets were assembled with slide low-friction ligatures, utilizing archwires with different diameters and alloys used for the alignment and leveling stage. Friction caused during the bracket/archwire interface and s…
Traction test of temporary dental cements
2017
Background Classic self-curing temporary cements obstruct the translucence of provisional restorations. New dual-cure esthetic temporary cements need investigation and comparison with classic cements to ensure that they are equally retentive and provide adequate translucence. The objective is to analyze by means of traction testing in a in vitro study the retention of five temporary cements. Material and methods Ten molars were prepared and ten provisional resin restorations were fabricated using CAD-CAM technology (n=10). Five temporary cements were selected: self-curing temporary cements, Dycal (D), Temp Bond (TB), Temp Bond Non Eugenol (TBNE); dual-curing esthetic cements Temp Bond Clear…
Influence of Drilling Technique on the Radiographic, Thermographic, and Geomorphometric Effects of Dental Implant Drills and Osteotomy Site Preparati…
2020
The aim of this comparative study is to analyze the influence of drilling technique on the radiographic, thermographic, and geomorphometric effects of dental implant drills and osteotomy site preparations. One hundred and twenty osteotomy site preparations were performed on sixty epoxy resin samples using three unused dental implant drill systems and four drilling techniques performed with a random distribution into the following study groups: Group A: drilling technique performed at 800 rpm with irrigation (n = 30)
Effect of nonsurgical periodontal treatment in patients with periodontitis and rheumatoid arthritis: a systematic review
2016
Background: Periodontitis has been regarded as a potential risk factor for rheumatoid arthritis (RA). A systematic review is made to determine whether nonsurgical periodontal treatment in patients with RA offers benefits in terms of the clinical activity and inflammatory markers of the disease. Material and Methods: A search was made of the Medline-PubMed, Cochrane, Embase and Scopus databases to identify studies on the relationship between the two disease processes, and especially on the effects of nonsurgical treatment in patients of this kind. The search was based on the following keywords: rheumatoid arthritis AND periodontitis (MeSH), rheumatoid arthritis AND periodontal treatment . Re…
In vitro comparative study on the friction of stainless steel wires with and without Orthospeed (JAL 90458) on an inclined plane
2016
Background: During the treatment of orthodontics, in the mechanics of slide, there takes place friction, which they reduce the slide of the arch across bracket. Therefore, clinical there takes place an increase of the time of treatment. There are different the technologies that try to reduce this friction, as the self-ligating braces. The purpose of this study was to research the in vitro behavior of JAL 90458 as a buffering agent which reduces friction between brackets and stainless steel arch wires of different cross sections and sizes. Material and Methods: Three types of stainless steel wires with different cross sections and three types of ligatures were used with and without JAL 90458…