Search results for "030218 nuclear medicine & medical imaging"
showing 10 items of 1054 documents
Validation of the Strain Assessment of a Phantom of Abdominal Aortic Aneurysm: Comparison of Results Obtained From Magnetic Resonance Imaging and Ste…
2018
Predicting aortic aneurysm ruptures is a complex problem that has been investigated by many research teams over several decades. Work on this issue is notably complex and involves both the mechanical behavior of the artery and the blood flow. Magnetic resonance imaging (MRI) can provide measurements concerning the shape of an organ and the blood that flows through it. Measuring local distortion of the artery wall is the first essential factor to evaluate in a ruptured artery. This paper aims to demonstrate the feasibility of this measure using MRI on a phantom of an abdominal aortic aneurysm (AAA) with realistic shape. The aortic geometry is obtained from a series of cine-MR images and reco…
A smart tele-cytology point-of-care platform for oral cancer screening.
2019
Early detection of oral cancer necessitates a minimally invasive, tissue-specific diagnostic tool that facilitates screening/surveillance. Brush biopsy, though minimally invasive, demands skilled cyto-pathologist expertise. In this study, we explored the clinical utility/efficacy of a tele-cytology system in combination with Artificial Neural Network (ANN) based risk-stratification model for early detection of oral potentially malignant (OPML)/malignant lesion. A portable, automated tablet-based tele-cytology platform capable of digitization of cytology slides was evaluated for its efficacy in the detection of OPML/malignant lesions (n = 82) in comparison with conventional cytology and hist…
Simulation study of transcatheter heart valve implantation in patients with stenotic bicuspid aortic valve
2019
Bicuspid aortic valve (BAV) anatomy has routinely been considered an exclusion in the setting of transcatheter aortic valve implantation (TAVI) because of the large dimension of the aortic annulus having a more calcified, bulky, and irregular shape. The study aims to develop a patient-specific computational framework to virtually simulate TAVI in stenotic BAV patients using the Edwards SAPIEN 3 valve (S3) and its improved version SAPIEN 3 Ultra and quantify stent frame deformity as well as the severity of paravalvular leakage (PVL). Specifically, the aortic root anatomy of n.9 BAV patients who underwent TAVI was reconstructed from pre-operative CT imaging. Crimping and deployment of S3 fram…
Accuracy of CT and MRI to assess resection margins in primary malignant bone tumours having histology as the reference standard.
2018
AIM To evaluate the accuracy of magnetic resonance imaging (MRI) and computed tomography (CT) in assessing the resection margins of primary malignant bone tumours. MATERIALS AND METHODS Resected primary malignant bone tumour specimens removed from 46 patients (27 male; mean age: 48±22 years) were imaged using MRI (fat-saturated proton density-weighted and three-dimensional fat-suppressed T1-weighted gradient-recalled-echo) and CT immediately after surgery. A radiologist and an orthopaedist evaluated bone and soft-tissue margins of the specimens on both examinations. Histological evaluation was performed by a senior orthopaedic oncology pathologist. Margins were classified as R0 (safe margin…
The 15-Country Collaborative Study of Cancer Risk among Radiation Workers in the Nuclear Industry: Estimates of Radiation-Related Cancer Risks
2007
International audience; A 15-Country collaborative cohort study was conducted to provide direct estimates of cancer risk following protracted low doses of ionizing radiation. Analyses included 407,391 nuclear industry workers monitored individually for external radiation and 5.2 million person-years of follow-up. A significant association was seen between radiation dose and all-cause mortality [excess relative risk (ERR) 0.42 per Sv, 90% CI 0.07, 0.79; 18,993 deaths]. This was mainly attributable to a dose-related increase in all cancer mortality (ERR/Sv 0.97, 90% CI 0.28, 1.77; 5233 deaths). Among 31 specific types of malignancies studied, a significant association was found for lung cance…
Peptide Receptor Radionuclide Therapy Combined With Chemotherapy in Patients With Neuroendocrine Tumors
2019
Combinations of therapies may enhance therapeutic effects without significantly increasing the incidence of adverse events. However, there are few data regarding survival after concomitant chemotherapy and peptide receptor radionuclide therapy (PRRT) with [Lu]Lu-octreotate in patients with neuroendocrine tumors (NETs). Thus, we explored the outcome of this combination of therapies.Fifteen patients with somatostatin receptor-positive, rapidly progressive G2/G3 NETs during chemotherapy or PRRT alone from 2 German cancer centers were included in the retrospective analysis. The patients received a combination of PRRT and chemotherapy with temozolomide (n = 3) or temozolomide plus capecitabine (…
Early evaluation using a radiomic signature of unresectable hepatic metastases to predict outcome in patients with colorectal cancer treated with FOL…
2020
PurposeThe objective of this study was to build and validate a radiomic signature to predict early a poor outcome using baseline and 2-month evaluation CT and to compare it to the RECIST1·1 and morphological criteria defined by changes in homogeneity and borders.MethodsThis study is an ancillary study from the PRODIGE-9 multicentre prospective study for which 491 patients with metastatic colorectal cancer (mCRC) treated by 5-fluorouracil, leucovorin and irinotecan (FOLFIRI) and bevacizumab had been analysed. In 230 patients, computed texture analysis was performed on the dominant liver lesion (DLL) at baseline and 2 months after chemotherapy. RECIST1·1 evaluation was performed at 6 months. …
Cohort Profile: the EPI-CT study: a European pooled epidemiological study to quantify the risk of radiation-induced cancer from paediatric CT
2018
International audience; •The multinational EPI-CT study was set-up in 2011 to provide direct estimates of risk of solid tumours and leukaemia among children and young adults who underwent computed tomography (CT) scanning and to consolidate the scientific basis for optimization of paediatric CT protocols and patient protection.•Under a common protocol, cohort studies were conducted in Belgium, Denmark, France, Germany, the Netherlands, Norway, Spain, Sweden and the United Kingdom, coordinated by the International Agency for Research on Cancer (IARC). •The study recruited a total of about 950,000 patients having undergone at least one CT-scan before the age of 22 years. A total of 8.7 millio…
Moderate Hypofractionated Postprostatectomy Volumetric Modulated Arc Therapy With Daily Image Guidance (VMAT-IGRT): A Mono-institutional Report on Fe…
2017
The aim of this study was to evaluate the acute toxicity profiles of a moderate hypofractionated regimen with volumetric modulated arc therapy (VMAT) in patients with prostate cancer (PC) who underwent radical prostatectomy.From December 2012 to February 2016, 125 patients, previously having undergone radical prostatectomy, received adjuvant (64 patients) or salvage (61 patients) radiotherapy (RT) inside an institutional protocol of moderate hypofractionation schedule using the VMAT technique (Varian RapidArc, Palo Alto, CA). Eligible patients were 85 years old, with an Eastern Cooperative Oncology Group performance status of 0 to 2, histologically proven adenocarcinoma of the prostate with…
High-dose-rate brachytherapy boost for prostate cancer: Analysis of dose-volume histogram parameters for predicting late, rectal toxicity
2017
PURPOSE: To determine the significance of dose-volume histogram parameters for predicting late rectal toxicity (LRT) after single-fraction high-dose-rate brachytherapy (HDRBT) boost and external beam radiotherapy (EBRT) in prostate cancer. MATERIALS AND METHODS: Three hundred patients with intermediate- or high-risk prostate cancer were included between August 2010 and March 2015. Treatment comprised a single-fraction HDRBT boost of 15.0 Gy plus EBRT (46.0 Gy delivered in 23 fractions) or an HDRBT boost of 9.5 Gy plus EBRT (60.0 Gy delivered in 30 fractions) if the seminal vesicles were infiltrated using real-time transrectal ultrasound-based planning. LRT was evaluated every 3 months after…