Search results for "14"

showing 10 items of 9841 documents

Broadband microwave emission spectrum associated with kinetic instabilities in minimum-B ECR plasmas

2017

Plasmas of electron cyclotron resonance ion sources (ECRISs) are prone to kinetic instabilities due to the resonant heating mechanism resulting in anisotropic electron velocity distribution. Frequently observed periodic oscillations of extracted ion beam current in the case of high plasma heating power and/or strong magnetic field have been proven to be caused by cyclotrontype instabilities leading to a notable reduction and temporal variation of highly charged ion production. Thus, investigations of such instabilities and techniques for their suppression have become important topics in ECRIS research. The microwave emission caused by the instabilities contains information on the electron e…

010302 applied physicsPhysicsRange (particle radiation)microwave sourcesIon sourcesIon beamta114Highly charged ionPlasmaAstrophysics::Cosmology and Extragalactic Astrophysicsplasma instabilitiesmagnetic fieldsCondensed Matter PhysicsPlasma oscillationmagneettikentät01 natural sciences7. Clean energyElectron cyclotron resonanceIonPhysics::Plasma Physicsmicrowave spectra0103 physical sciencesAtomic physics010306 general physicsMicrowave
researchProduct

Time resolved measurements of hydrogen ion energy distributions in a pulsed 2.45 GHz microwave plasma

2017

A plasma diagnostic study of the Ion Energy Distribution Functions (IEDFs) of H+, H+2H2+, and H+3H3+ ions in a 2.45 GHz hydrogen plasma reactor called TIPS is presented. The measurements are conducted by using a Plasma Ion Mass Spectrometer with an energy sector and a quadrupole detector from HIDEN Analytical Limited in order to select an ion species and to measure its energy distribution. The reactor is operated in the pulsed mode at 100 Hz with a duty cycle of 10% (1 ms pulse width). The IEDFs of H+, H+2H2+, and H+3H3+ are obtained each 5 μs with 1 μs time resolution throughout the entire pulse. The temporal evolution of the plasma potential and ion temperature of H+ is derived from the d…

010302 applied physicsPhysicsRange (particle radiation)plasma sourcesta114plasma diagnosticsPlasmaCondensed Matter PhysicsMass spectrometry01 natural sciences7. Clean energyIon source010305 fluids & plasmasIonplasma dynamicsPhysics::Plasma Physics0103 physical sciencesThermal emittancePlasma diagnosticsionAtomic physicsMicrowaveplasma sheathsPhysics of Plasmas
researchProduct

Hydrogen plasma induced photoelectron emission from low work function cesium covered metal surfaces

2017

Experimental results of hydrogen plasma induced photoelectron emission from cesium covered metal surfaces under ion source relevant conditions are reported. The transient photoelectron current during the Cs deposition process is measured from Mo, Al, Cu, Ta, Y, Ni, and stainless steel (SAE 304) surfaces. The photoelectron emission is 2–3.5 times higher at optimal Cs layer thickness in comparison to the clean substrate material. Emission from the thick layer of Cs is found to be 60%–80% lower than the emission from clean substrates. peerReviewed

010302 applied physicsPhysicsta114HydrogenTantalumAnalytical chemistrytransitionchemistry.chemical_elementSubstrate (electronics)plasmasCondensed Matter Physics01 natural sciencesIon sourcework functions010305 fluids & plasmasion sourceschemistryAluminiumCaesium0103 physical sciencesWork functionLayer (electronics)photoemissionPhysics of Plasmas
researchProduct

Simulations on time-of-flight ERDA spectrometer performance

2016

The performance of a time-of-flight spectrometer consisting of two timing detectors and an ionization chamber energy detector has been studied using Monte Carlo simulations for the recoil creation and ion transport in the sample and detectors. The ionization chamber pulses have been calculated using Shockley-Ramo theorem and the pulse processing of a digitizing data acquisition setup has been modeled. Complete time-of-flight–energy histograms were simulated under realistic experimental conditions. The simulations were used to study instrumentation related effects in coincidence timing and position sensitivity, such as background in time-of-flight–energy histograms. Corresponding measurement…

010302 applied physicsPhysicsta114SpectrometerPhysics::Instrumentation and Detectorsbusiness.industryInstrumentationMonte Carlo methodDetector7. Clean energy01 natural sciencesMonte Carlo simulationsNuclear physicsTime of flightRecoilOpticsData acquisitiontime-of-flight spectrometers0103 physical sciencesIonization chambersimulations010306 general physicsbusinessInstrumentationReview of Scientific Instruments
researchProduct

Cyclotron instability in the afterglow mode of minimum-B ECRIS.

2016

It was shown recently that cyclotron instability in non-equilibrium plasma of a minimum-B electron cyclotron resonance ion source (ECRIS) causes perturbation of the extracted ion current and generation of strong bursts of bremsstrahlung emission, which limit the performance of the ion source. The present work is devoted to the dynamic regimes of plasma instability in ECRIS operated in pulsed mode. Instability develops in decaying plasma shortly after heating microwaves are switched off and manifests itself in the form of powerful pulses of electromagnetic emission associated with precipitation of high energy electrons. Time-resolved measurements of microwave emission bursts are presented. I…

010302 applied physicsPhysicsta114ta213Astrophysics::High Energy Astrophysical Phenomenaplasma instabilityCyclotronBremsstrahlungPlasma01 natural sciencesInstabilityIon sourceElectron cyclotron resonance010305 fluids & plasmaslaw.inventionTwo-stream instabilityPhysics::Plasma Physicslaw0103 physical scienceselectron cyclotron resonance ion sourcesAtomic physicsInstrumentationIon cyclotron resonanceThe Review of scientific instruments
researchProduct

Broadband Ultrahigh-Resolution Spectroscopy of Particle-Induced X Rays: Extending the Limits of Nondestructive Analysis

2016

Nondestructive analysis (NDA) based on x-ray emission is widely used, for example, in the semiconductor and concrete industries. Here, we demonstrate significant quantitative and qualitative improvements in broadband x-ray NDA by combining particle-induced emission with detection based on superconducting microcalorimeter arrays. We show that the technique offers great promise in the elemental analysis of thin-film and bulk samples, especially in the difficult cases where tens of different elements with nearly overlapping emission lines have to be identified down to trace concentrations. We demonstrate the efficiency and resolving capabilities by spectroscopy of several complex multielement …

010302 applied physicsSuperconductivityPhysicsspectroscopyta114nondestructive analysisspektroskopiaNondestructive analysisGeneral Physics and Astronomyx-rays01 natural sciencesImaging phantomTheoretical physicsUltrahigh resolution0103 physical sciencesParticleAtomic physics010306 general physicsSpectroscopyPhysical Review Applied
researchProduct

Oxy-nitrides characterization with a new ERD-TOF system

2017

Abstract A new time-of-flight (TOF) camera was installed on Elastic Recoil Detection (ERD) measurement setup on the Tandem Accelerator at Universite de Montreal. The camera consists of two timing detectors, developed and built by the Jyvaskyla group, that use a thin carbon foil and microchannel plates (MCP) to produce the start and stop signals. The position of the first detector is fixed at 18 cm from the target, while the position of the second detector can be varied between 50 and 90 cm from the first detector. This allows to increase time resolution by increasing the distance between the time-of-flight detectors or to increase solid angle by decreasing the distance. Moving the detector …

010302 applied physicsToF-ERDANuclear and High Energy PhysicsIon beam analysisMicrochannelMaterials scienceta114Physics::Instrumentation and Detectorsbusiness.industryDetectorSolid angleion beam analysis02 engineering and technology021001 nanoscience & nanotechnology01 natural sciencesSignalelastic recoil detectionElastic recoil detectionOpticsPosition (vector)0103 physical sciences0210 nano-technologybusinessInstrumentationEnergy (signal processing)Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct

Ion source research and development at University of Jyväskylä: Studies of different plasma processes and towards the higher beam intensities

2015

MonPS16; International audience; The long-term operation of high charge state electron cyclotron resonance ion sources fed withhigh microwave power has caused damage to the plasma chamber wall in several laboratories.Porosity, or a small hole, can be progressively created in the wall on a year time scale, which cancause a water leak from the cooling system into the plasma chamber vacuum. A burnout of theVENUS chamber is investigated. Information on the hole formation and on the necessary localhot electron power density is presented. Next, the hot electron flux to the wall is studied bymeans of simulations. First, the results of a simple model assuming that electrons are fullymagnetized and …

010302 applied physicsbeam intensityMaterials scienceta114ta213plasma diagnostics[PHYS.PHYS.PHYS-ACC-PH]Physics [physics]/Physics [physics]/Accelerator Physics [physics.acc-ph]Cyclotron resonanceElectronPlasma7. Clean energy01 natural sciencesElectron cyclotron resonanceIon source010305 fluids & plasmasIonBeamlinePhysics::Plasma Physics0103 physical scienceselectron cyclotron resonance ion sourcesPlasma diagnosticsAtomic physicsInstrumentation
researchProduct

Gold/Isophorone Interaction Driven by Keto/Enol Tautomerization

2016

The binding behavior of isophorone (C9H14O) to Au adatoms and clusters deposited on MgO/Ag(001) thin films is investigated by scanning tunneling microscopy (STM) and density functional theory (DFT). The STM data reveal the formation of various metal/organic complexes, ranging from Au1/isophorone pairs to larger Au aggregates with molecules bound to their perimeter. DFT calculations find the energetically preferred keto-isophorone to be unreactive toward gold, while the enol-tautomer readily binds to Au monomers and clusters. The interaction is governed by electrostatic forces between the hydroxyl group of the enol and negative excess charges residing on the ad-gold. The activation barrier b…

010402 general chemistryPhotochemistry01 natural sciencesChemical reactionlaw.inventionchemistry.chemical_compoundlawketo-enol tautomerismgold compoundsMoleculePhysical and Theoretical Chemistryta116Isophoroneta114010405 organic chemistryKeto–enol tautomerismEnolTautomer0104 chemical sciencesSurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialsisophoroneGeneral EnergychemistryDensity functional theoryScanning tunneling microscopeJournal of Physical Chemistry C
researchProduct

Titanocene–gold complexes containing N-heterocyclic carbene ligands inhibit growth of prostate, renal, and colon cancers in vitro

2016

We report on the synthesis, characterization, and stability studies of new titanocene complexes containing a methyl group and a carboxylate ligand (mba = −OC(O)-p-C6H4-S−) bound to gold(I)−N-heterocyclic carbene fragments through the thiolate group: [(η5 -C5H5)2TiMe(μ-mba)Au(NHC)]. The cytotoxicities of the heterometallic compounds along with those of novel monometallic gold−N-heterocyclic carbene precursors [(NHC)Au(mbaH)] have been evaluated against renal, prostate, colon, and breast cancer cell lines. The highest activity and selectivity and a synergistic effect of the resulting heterometallic species was found for the prostate and colon cancer cell lines. The colocalization of both tita…

010405 organic chemistryLigandStereochemistryOrganic Chemistry010402 general chemistrymedicine.disease01 natural sciencesArticleIn vitro3. Good health0104 chemical sciencesInorganic Chemistrychemistry.chemical_compoundProstate cancermedicine.anatomical_structurechemistryProstatemedicineCarboxylatePhysical and Theoretical ChemistryQD0146SelectivityCarbeneMethyl group
researchProduct