Search results for "20(60)"
showing 10 items of 368 documents
Collagen membranes of dermal and pericardial origin-In vivo evolvement of vascularization over time.
2020
Aim of the study was to compare the evolvement of vascularization over time of collagen membranes (CMs) of dermal and pericardial origin in an in vivo animal study. Twenty-eight mice underwent implantation of three commercially available CM derived from porcine dermis (homogenous structure: CM1 (Control 1) and bilayer structure: CM2 [Control 2]), from porcine pericardium (CM3; Test 1) as well as CM3 sprayed with silica-enhanced nanostructured hydroxyapatite (CM4, Test 2). After 3, 6, 9, and 12 days, intravital fluorescence microscopy was conducted for determination of capillary diameter, density, flow, and length. At Day 12, samples were examined immunohistologically for expression of fibro…
Particle image velocimetry study of the celiac trunk hemodynamic induced by continuous-flow left ventricular assist device
2017
Abstract Whereas left ventricular assist device (LVAD) is the gold-standard therapy for patients with heart failure, gastrointestinal bleeding is one of the most common complications. LVAD implantation may remarkably impact aortic hemodynamics so that experimental and computational flow analyses can be used to study the disease mechanisms. Here we present an experimentally-calibrated computational model of the celiac trunk hemodynamic of a LVAD-supported patient who experienced bleeding after device implantation. Specifically, both particle image velocimetry (PIV) and echocardiography were used to measure and compare flow distributions in each branch of a phantom model of the patient abdomi…
Computational fluid dynamics in the assessment of patients' postoperative status after glottis-widening surgery
2017
Background. Computational fluid dynamics (CFD), a rapidly developing instrument with a number of practical applications, allows calculation and visualization of the changing parameters of airflow in the upper respiratory tract. Objectives. The aim of this study was to demonstrate the advantages of CFD as an instrument for noninvasive tests of the larynx in patients who had undergone surgical treatment due to bilateral vocal fold paralysis. Material and Methods. Surface measurements of the glottic space were made during maximum adduction of the vocal folds. Additionally, the following spirometric parameters were determined: forced vital capacity (FVC), forced expiratory volume in the first s…
Shear stress alterations in the celiac trunk of patients with a continuous-flow left ventricular assist device as shown by in-silico and in-vitro flo…
2017
Background The use of left ventricular assist devices (LVADs) to treat advanced cardiac heart failure is constantly increasing, although this device leads to high risk for gastrointestinal bleeding. Methods Using in-silico flow analysis, we quantified hemodynamic alterations due to continuous-flow LVAD (HeartWare, Inc., Framingham, MA) in the celiac trunk and major branches of the abdominal aorta, and then explored the relationship between wall shear stress (WSS) and celiac trunk orientation. To assess outflow from the aortic branch, a 3-dimensional-printed patient-specific model of the celiac trunk reconstructed from an LVAD-supported patient was used to estimate echocardiographic outflow …
General method for automated feature extraction and selection and its application for gender classification and biomechanical knowledge discovery of …
2020
Modern technologies enable to capture multiple biomechanical parameters often resulting in relational data. The current work proposes a generally applicable method comprising automated feature extraction, ensemble feature selection and classification to best capture the potentials of the data also for generating new biomechanical knowledge. Its benefits are demonstrated in the concrete biomechanically and medically relevant use case of gender classification based on spinal data for stance and gait. Very good results for accuracy were obtained using gait data. Dynamic movements of the lumbar spine in sagittal and frontal plane and of the pelvis in frontal plane best map gender differences.
Comparison of short-term heart rate variability indexes evaluated through electrocardiographic and continuous blood pressure monitoring
2019
Heart rate variability (HRV) analysis represents an important tool for the characterization of complex cardiovascular control. HRV indexes are usually calculated from electrocardiographic (ECG) recordings after measuring the time duration between consecutive R peaks, and this is considered the gold standard. An alternative method consists of assessing the pulse rate variability (PRV) from signals acquired through photoplethysmography, a technique also employed for the continuous noninvasive monitoring of blood pressure. In this work, we carry out a thorough analysis and comparison of short-term variability indexes computed from HRV time series obtained from the ECG and from PRV time series …
Bone mineral density of the proximal femur after hip resurfacing arthroplasty: 1-year follow-up study
2011
Abstract Background Hip resurfacing arthroplasty (HRA) is considered a bone-preserving procedure and may eliminate proximal femoral stress shielding and osteolysis. However, in addition to implant-related stress-shielding factors, various patient-related factors may also have an effect on bone mineral density (BMD) of the proximal femur in patients with HRA. Thus, we studied the effects of stem-neck angle, demographic variables, and physical functioning on the BMD of the proximal femur in a one-year follow-up. Methods Thirty three patients (9 females and 24 males) with a mean (SD) age of 55 (9) years were included in the study. BMD was measured two days and 3, 6, and 12 months postoperative…
Human nasoseptal chondrocytes maintain their differentiated phenotype on PLLA scaffolds produced by thermally induced phase separation and supplement…
2018
Damage of hyaline cartilage such as nasoseptal cartilage requires proper reconstruction, which remains challenging due to its low intrinsic repair capacity. Implantation of autologous chondrocytes in combination with a biomimetic biomaterial represents a promising strategy to support cartilage repair. Despite so far mostly tested for bone tissue engineering, bioactive glass (BG) could exert stimulatory effects on chondrogenesis. The aim of this work was to produce and characterize composite porous poly(L-lactide) (PLLA)/1393BG scaffolds via thermally induced phase separation (TIPS) technique and assess their effects on chondrogenesis of nasoseptal chondrocytes. The PLLA scaffolds without or…
The influence of wearing ski-boots with different rigidity characteristics on postural control
2018
External supports that reduce ankle joint mobility such as ski-boots can impair postural control of healthy participants. Although this disruptive effect has been attributed to the rigidity of the external supports, the results remained controversial and no study has been conducted in order to evaluate the influence of ski-boots rigidity. Hence, the question about the influence of ankle support rigidity on postural control remains open. This study was therefore undertaken in order to investigate the effect of ski-boots rigidity on postural control. Ten healthy active participants were recruited. The wearing of soft and rigid ski-boots was compared to barefoot while standing on a seesaw gene…
Biomechanical and viscoelastic properties of the ankle muscles in men with previous history of ankle sprain
2020
Abstract In this study, we aimed to explore the impact of previous history of lateral ankle sprain on the mechanical and viscoelastic properties of the tibialis anterior (TA), peroneus longus (PL) and gastrocnemius lateralis (GL) and medialis (GM) in asymptomatic men. For this purpose, a group of 26 men with previous history of lateral ankle sprain (ASG) and a control group (CG) of 29 healthy counter-parts participated in this study. Tone, stiffness, elasticity and mechanical stress relaxation time were measured using a myotonometer in a single session. Higher tone was noted for TA and GL in ASG as compared to CG (effect size of Cohen’s d = 0.57 [p = 0.04] and 0.59 [p = 0.04], respectively)…