Comparaison de la mesure des déformations de fantômes de l’aorte à partir d’image obtenues par IRM et stéréovision

2015

International audience; The study of the wall strain distribution could be helpful to improve the decision criterion for surgery of aortic aneurysm. Recently, numerical simulations can complete the data obtained from imaging measurement in order to develop reliable models. However, the used medical imaging tools are not experimentally validated, in metrological point of view. The aim of this study focused on accuracy and reliability of measurement obtained from kinetic MR sequences. The measures of deformations from MRI were compare to those obtained from stereovision system. Cylindrical phantom of silicone material similar to arterial behavior simulated a symmetric aneurysm was designed. A…

Physics[ SPI.MECA.GEME ] Engineering Sciences [physics]/Mechanics [physics.med-ph]/Mechanical engineering [physics.class-ph]Digital image correlationCardiac cycle0206 medical engineering3D reconstructionCylindrical phantom02 engineering and technology030204 cardiovascular system & hematology020601 biomedical engineeringImaging phantomMetrology[SPI.MECA.GEME]Engineering Sciences [physics]/Mechanics [physics.med-ph]/Mechanical engineering [physics.class-ph]03 medical and health sciences0302 clinical medicineMedical imaginganévrisme aorte abdominaleIRM cardiaquemesure par stéréovision des déformationsEcg signal[SPI.MECA.GEME] Engineering Sciences [physics]/Mechanics [physics.med-ph]/Mechanical engineering [physics.class-ph]métrologieSimulationBiomedical engineering
researchProduct

Reliability of Local Activation Waves Features to Characterize Paroxysmal Atrial Fibrillation Substrate During Sinus Rhythm

2020

[EN] Analysis of coronary sinus (CS) electrograms (EGMs) is vastly used for the assessment of the atrial fibrillation (AF) substrate. As a catheter consists of five dipoles (distal, mid-distal, medial, mid-proximal, proximal), results may vary upon the employed channel: myocardial contraction and bad contact are unavoidable factors affecting the recording. This work aims to specify the most reliable channels in catching AF dynamics, using 44 multichannel bipolar CS recordings in sinus rhythm (SR) of paroxysmal AF with 1-5 minutes duration. Local activation waves (LAWs) were detected and main features obtained: duration, amplitude, area and correlation between dominant morphologies of each c…

Physicsmedicine.medical_specialtyParoxysmal atrial fibrillation0206 medical engineeringAtrial fibrillation02 engineering and technology030204 cardiovascular system & hematologymedicine.disease020601 biomedical engineeringSubstrate (marine biology)TECNOLOGIA ELECTRONICA03 medical and health sciences0302 clinical medicineAmplitudeDuration (music)Internal medicineAtrial FibrillationCardiologymedicineSinus rhythmCoronary sinus
researchProduct

Photoplethysmography in dogs and cats: a selection of alternative measurement sites for a pet monitor.

2018

Objective Photoplethysmography (PPG) is an increasingly popular health and well-being tool for monitoring heart rate and oxygen saturation. Due to the pigmentation and hairiness of dogs and cats, a pulse oximeter is routinely placed solely on the tongue. As this approach is feasible only for pet monitor use during surgical procedures, we investigate PPG signal quality on several other measurement sites that would be better tolerated by conscious animals. Approach Acquired PPG signals are analyzed by four signal quality indices: mean baseline, signal power, kurtosis, and tolerance score. Main results In dogs, the metacarpus and tail can be substituted for oral pulse oximeter placement since …

Physiology0206 medical engineeringBiomedical EngineeringBiophysics02 engineering and technologySignal03 medical and health sciences0302 clinical medicineDogsSignal qualityPhysiology (medical)PhotoplethysmogramHeart rateMedicineAnimalsPhotoplethysmographyOxygen saturation (medicine)CATSPulse (signal processing)business.industrySignal Processing Computer-AssistedPetsSurgical procedures020601 biomedical engineeringCatssense organsbusiness030217 neurology & neurosurgeryBiomedical engineeringPhysiological measurement
researchProduct

Interictal cardiorespiratory variability in temporal lobe and absence epilepsy in childhood

2015

It is well known that epilepsy has a profound effect on the autonomic nervous system, especially on the autonomic control of heart rate and respiration. This effect has been widely studied during seizure activity, but less attention has been given to interictal (i.e. seizure-free) activity. The studies that have been done on this topic, showed that heart rate and respiration can be affected individually, even without the occurrence of seizures. In this work, the interactions between these two individual physiological variables are analysed during interictal activity in temporal lobe and absence epilepsy in childhood. These interactions are assessed by decomposing the predictive information …

PhysiologyInformation Theory02 engineering and technologyElectroencephalographyMultimodal Imaging01 natural sciencesAutonomic controlElectrocardiographyEpilepsy0302 clinical medicineHeart RateHeart rate variabilityChildmedicine.diagnostic_testSISTARespirationheart rate variabilityElectroencephalographySignal Processing Computer-Assistedtemporal lobe epilepsy3. Good healthabsence epilepsyCardiologyPsychologymedicine.medical_specialty0206 medical engineeringBiophysicsBiomedical EngineeringTemporal lobe03 medical and health sciencesInternal medicinePhysiology (medical)0103 physical sciencesRespirationHeart ratemedicineHumansIctal010306 general physicsinformation dynamicbusiness.industryCardiorespiratory fitnessmedicine.disease020601 biomedical engineeringAutonomic nervous systemEpilepsy AbsenceEpilepsy Temporal LobeBiophysicSettore ING-INF/06 - Bioingegneria Elettronica E InformaticaepilepsyTransfer entropybusinessNeuroscience030217 neurology & neurosurgery
researchProduct

An emotional contribution to the Festschrift of the Journal of Biomaterials Science for Teiji Tsuruta

2017

AbstractIt is a honor for me to contribute to the ‘Festschrift for Teiji Tsuruta’! Being old, it is much easier for me to look back than to think ahead. Thus, please allow me to make a few ‘historical remarks’ about Biomaterials and Biotechnology, long before Science stepped in. Remarks about Georg Christoph Lichtenberg, the Gottinger physicist and philosopher, and his relation to Teiji Tsuruta. And talking about him as teacher, one cannot do it without looking at Hermann Staudinger and his dreams.

Polymer sciencePhilosophy0206 medical engineeringBiomedical EngineeringBiophysicsArt historyBioengineering02 engineering and technologyLichtenberg figure021001 nanoscience & nanotechnology020601 biomedical engineeringBiomaterialsHonor0210 nano-technologyRelation (history of concept)Journal of Biomaterials Science, Polymer Edition
researchProduct

Crosslinked α,β-Polyasparthydrazide Micromatrices for Controlled Release of Anticancer Drugs

1995

The preparation of new hydrogels by the reaction of α,β- polyasparthydrazide and glutaraldehyde is reported. A different crosslinking degree was obtained by varying the ratio crosslinking agent/polymer which influenced the swelling behavior of the gel. 5-Fluorouracil, was incorporated into the matrices during the crosslinking reaction and in vitro release studies were performed in simulated gastric juice (pH 1.1) and pH 7.4 buffer solution. The hydrogels prepared were chemically stable in the dissolution media. The observed data show the potential application of these new matrices for peroral administration of anticancer agents.

Polymers and Plastics0206 medical engineeringBioengineeringmacromolecular substances02 engineering and technologyBiomaterialschemistry.chemical_compoundPolymer chemistryMaterials ChemistrymedicineDissolutionchemistry.chemical_classificationtechnology industry and agriculturePolymerBuffer solution021001 nanoscience & nanotechnology020601 biomedical engineeringControlled releaseIn vitrochemistrySelf-healing hydrogelsGlutaraldehydeSwellingmedicine.symptom0210 nano-technologyNuclear chemistryJournal of Bioactive and Compatible Polymers
researchProduct

Polyphosphoester surfactants as general stealth coatings for polymeric nanocarriers

2020

Opsonization of nanocarriers is one of the most important biological barriers for controlled drug delivery. The typical way to prevent such unspecific protein adsorption and thus fast clearance by the immune system is the covalent modification of drug delivery vehicles with poly(ethylene glycol) (PEG), so-called PEGylation. Recently, polyphosphoesters (PPEs) were identified as adequate PEG substitutes, however with the benefits of controllable hydrophilicity, additional chemical functionality, or biodegradability. Here, we present a general strategy by non-covalent adsorption of different nonionic PPE-surfactants to nanocarriers with stealth properties. Polyphosphoester surfactants with dif…

Polymers0206 medical engineeringBiomedical EngineeringUT-Hybrid-DProtein Corona02 engineering and technologyStealth effectBiochemistryPolyethylene GlycolsBiomaterialschemistry.chemical_compoundSurface-Active AgentsPolyphosphoesterPEG ratioMolecular Biologychemistry.chemical_classificationDrug CarriersChemistryGeneral MedicinePolymer021001 nanoscience & nanotechnology020601 biomedical engineeringCombinatorial chemistryPEGProtein coronaDrug deliveryDrug deliveryPEGylationNanoparticlesNanocarriers0210 nano-technologyEthylene glycolBiotechnologyProtein adsorption
researchProduct

Effects of different etching strategies on the microtensile repair bond strength of beautifil II giomer material

2018

Background Considering the differences in the filler particles between giomer and conventional composite resins and the importance of these fillers in the repair bond strength, the aim was to evaluate the effects of different etching strategies with phosphoric acid (PA) and hydrofluoric acid (HF) on the microtensile repair bond strength (µTRBS) of giomer. Material and Methods Ten giomer blocks were randomly assigned into 10: 1) control; 2) 37%PA-20s; 3) 3%HF-20s; 4) 3%HF-120s; 5) 9.6%HF-20s; 6) 9.6%HF-120s; 7) 37%PA-20s + 3%HF-120s; 8) 37%PA-20s + 9.6%HF-120s; 9) 3%HF-120s + 37%PA-20s; 10) 9.6%HF-120s + 37%PA-20s. In all groups, the One-Step Plus bonding system was applied and the new giome…

Post hocBond strengthResearch0206 medical engineering030206 dentistry02 engineering and technology:CIENCIAS MÉDICAS [UNESCO]020601 biomedical engineeringApplication timeOperative Dentistry and Endodontics03 medical and health scienceschemistry.chemical_compound0302 clinical medicineHydrofluoric acidchemistryEtching (microfabrication)UNESCO::CIENCIAS MÉDICASGeneral DentistryPhosphoric acidNuclear chemistry
researchProduct

Detecting Ankle Instability With an Instrumented Ankle Arthrometer: An Experimental Study.

2019

A new instrumented device was developed to quantify ankle joint stability during an anterior talar drawer test. The aim of the present study was to validate this device comparing bone kinematics with arthrometer measurement outcomes. An anterior talar drawer test was performed with 14 cadaver legs using a custom instrumented ankle arthrometer. Using clusters of bone-pin markers, the relative three-dimensional movement of calcaneus, talus, and fibula was simultaneously measured. Anterior drawer test was applied on the intact foot and after sequentially sectioning the anterior talofibular ligament, the calcaneofibular ligament, and the posterior talofibular ligament. Cutting the anterior talo…

Posterior talofibular ligamentJoint InstabilityMaleMovement0206 medical engineeringJoint stability02 engineering and technologyDrawer testTalus03 medical and health sciences0302 clinical medicineCadavermedicineHumansOrthopedics and Sports MedicineCalcaneofibular ligamentAged030203 arthritis & rheumatologyOrthodonticsAged 80 and overArthrometry Articularbusiness.industryAnterior talofibular ligamentmusculoskeletal system020601 biomedical engineeringBiomechanical Phenomenamedicine.anatomical_structureLigaments ArticularFemaleCalcaneusAnklebusinessAnkle JointJournal of orthopaedic research : official publication of the Orthopaedic Research Society
researchProduct

Color stability of CAD/CAM Zirconia ceramics following exposure to acidic and staining drinks.

2017

Background The aim of this in vitro study was to evaluate the color stability of CAD/CAM Zirconia ceramics following exposure to acidic drink (Coca Cola) and after exposure to staining solution (coffee). Material and Methods All the samples were immersed in different staining solutions over a 28-day test period. A colorimetric evaluation according to the CIE L*a*b* system was performed by a blind trained operator at 7, 14, 21, 28 days of the staining process. Shapiro Wilk test and Kruskal-Wallis ANOVA were applied to assess significant differences among restorative materials. Paired t-test was applied to test which CIE L*a*b* parameters significantly changed after immersion in staining solu…

Prosthetic DentistryChemistryResearch0206 medical engineering030206 dentistry02 engineering and technology:CIENCIAS MÉDICAS [UNESCO]020601 biomedical engineeringCoca colaStaining03 medical and health sciences0302 clinical medicinevisual_artUNESCO::CIENCIAS MÉDICASvisual_art.visual_art_mediumIn vitro studyCubic zirconiaFood scienceCeramicGeneral DentistryJournal of clinical and experimental dentistry