Automatic segmentation and 3D reconstruction of intravascular ultrasound images for a fast preliminar evaluation of vessel pathologies.
2007
Abstract Intravascular ultrasound (IVUS) imaging is used along with X-ray coronary angiography to detect vessel pathologies. Manual analysis of IVUS images is slow and time-consuming and it is not feasible for clinical purposes. A semi-automated method is proposed to generate 3D reconstructions from IVUS video sequences, so that a fast diagnose can be easily done, quantifying plaque length and severity as well as plaque volume of the vessels under study. The methodology described in this work has four steps: a pre-processing of IVUS images, a segmentation of media–adventitia contour, a detection of intima and plaque and a 3D reconstruction of the vessel. Preprocessing is intended to remove …
Towards a real-time 3D shape reconstruction using a structured light system
2005
This paper deals with 3D shape reconstruction using a structured light system (SLS) which projects a matrix of laser rays onto the scene to be analyzed. The intrinsic problem of such a system is the correspondence problem solving, which in this particular case amounts to matching up the imaged spots and the originating laser rays. In this paper, we propose a method for automatically obtaining configurations of the system (COS) (i.e. the relative positions of the camera, laser projector, and measuring scene) that permit to achieve a direct and unambiguous correspondence. After, we propose a splitting cell algorithm, which efficiently performs a real-time correspondence procedure. Experimenta…
Genetic algorithms for 3d reconstruction with supershapes
2009
Supershape model is a recent primitive that represents numerous 3D shapes with several symmetry axes. The main interest of this model is its capability to reconstruct more complex shape than superquadric model with only one implicit equation. In this paper we propose a genetic algorithms to re-construct a point cloud using those primitives. We used the pseudo-Euclidean distance to introduce a threshold to handle real data imperfection and speed up the process. Simulations using our proposed fitness functions and a fitness function based on inside-outside function show that our fitness function based on the pseudo-Euclidean distance performs better.
Accurate registration of random radiographic projections based on three spherical references for the purpose of few-view 3D reconstruction
2008
Precise registration of radiographic projection images acquired in almost arbitrary geometries for the purpose of three-dimensional (3D) reconstruction is beset with difficulties. We modify and enhance a registration method [R. Schulze, D. D. Bruellmann, F. Roeder, and B. d'Hoedt, Med. Phys. 31, 2849-2854 (2004)] based on coupling a minimum amount of three reference spheres in arbitrary positions to a rigid object under study for precise a posteriori pose estimation. Two consecutive optimization procedures (a, initial guess; b, iterative coordinate refinement) are applied to completely exploit the reference's shadow information for precise registration of the projections. The modification h…
Active Lighting Applied to Shape from Polarization
2006
We present a new way of solving the ambiguity that appears in the shape from polarization method. This ambiguity, concerning the normals orientation of the surface, was previously solved thanks to a propagation algorithm. In this paper, the ambiguity is solved thanks to a special active lighting. This method is less time computing and is more robust to noise acquisition. We first demonstrate how to compute the right normals on the whole surface. Then, we show an application on the 3D reconstruction of a specular metallic object made by stamping and polishing.
Calculation of bone graft volume using 3D reconstruction system.
2010
Objectives: To obtain bone ?bioreplicas? for determining precisely the amount of biomaterial required for bone regeneration procedure. Study design: A case-control comparison with a total sample size of 20 cases, 10 control and 10 test samples. ?Bioreplicas? were generated from helical CAT scans with 0.5 mm slices, without 3D reconstruction or image filters. Bone defects in premolar and molar areas were treated with titanium mesh and xenograft (MP3) combined with resorbable carriers. Time taken to carry out procedures with and without the use of ?bioreplicas? (in minutes), discrepancies between the grafts performed with and without ?bioreplicas? and bone defects (mm), and postoperative comp…
Design and modelling a of bimodal camera system
2021
In computer vision, researchers face a challenging concern due to the limited field of view (FoV) when using standard cameras in capturing scenes. This problem of narrow FoV often encountered within applications that involve tasks which are related to the robot vision. Many authors have attempted, in different approaches, to solve this issue by fusing two cameras. However, they failed to improve the registration and fusing errors, where the obtained results still limited and not accurate enough. To deal with this limitation and decrease these errors, we propose a new method of camera calibration based on Interior-Point Optimisation (IPO) algorithm using transformation matrix estimation. Thi…
Optimization of a polarization imaging system for 3D measurements of transparent objects
2009
This paper presents a multispectral imaging system for 3D reconstruction of transparent objects based on "shape from polarization" technique. The originality of this work relies on a multispectral active lighting system which enables to cope with the two ambiguities on the zenith angle and azimuth angle. A calibration step allows optimising the polarimetric measurements. Example of a reconstructed transparent object is presented.
3D Reconstruction from Few Radiographic Projections Acquired in Arbitrary Geometry
2008
Combining Mendonça-Cipolla self-calibration and scene constraints
2011
International audience; In this paper, we propose a method that combines plane parallelism and the Mendonça/Cipolla self-calibration constraints. In our method each pair of images is treated independently and can therefore use a different pair of parallel planes not necessarily visible in the other views. While, for each pair of images, constraints on the singular values of the essential matrix provide two algebraic constraints on the intrinsic parameters, those we derive from plane parallelism have the advantage of providing two additional ones making the calibration of a no-skew camera possible from two images only.