Search results for "A(1)"

showing 10 items of 6089 documents

Ionization efficiency studies with charge breeder and conventional electron cyclotron resonance ion source

2013

Radioactive Ion Beams play an increasingly important role in several European research facility programs such as SPES, SPIRAL1 Upgrade, and SPIRAL2, but even more for those such as EURISOL. Although remarkable advances of ECRIS charge breeders (CBs) have been achieved, further studies are needed to gain insight on the physics of the charge breeding process. The fundamental plasma processes of charge breeders are studied in the frame of the European collaboration project, EMILIE, for optimizing the charge breeding. Important information on the charge breeding can be obtained by conducting similar experiments using the gas mixing and 2-frequency heating techniques with a conventional JYFL 14 …

010302 applied physicsIonizationMaterials scienceta114[PHYS.PHYS.PHYS-ACC-PH]Physics [physics]/Physics [physics]/Accelerator Physics [physics.acc-ph]Particle acceleratorCharge (physics)Plasma7. Clean energy01 natural sciencesIon sourceElectron cyclotron resonanceIonlaw.inventionNuclear physicsBreeder (animal)lawIonization0103 physical sciences010306 general physicsInstrumentationComputingMilieux_MISCELLANEOUS
researchProduct

The effect of plasma instabilities on the background impurities in charge breeder ECRIS

2017

International audience; Experimental observations of plasma instabilities in the 14.5 GHz PHOENIX charge breeder ECRIS are summarized. It has been found that the injection of 133Cs+ or 85Rb+ into oxygen discharge of the CB-ECRIS can trigger electron cyclotron instabilities, which results to sputtering of the surfaces exposed to the plasma, followed by up to an order of magnitude increase of impurity currents in the extracted n+ charge state distribution. The transition from stable to unstable plasma regime is caused by gradual accumulation and ionization of Cs/Rb altering the discharge parameters in 10 - 100 ms time scale, not by a prompt interaction between the incident ion beam and the EC…

010302 applied physicsMaterials scienceIon beamta114syklotronit[PHYS.PHYS.PHYS-ACC-PH]Physics [physics]/Physics [physics]/Accelerator Physics [physics.acc-ph]Buffer gasCyclotronPlasmaElectroncharge breederplasmafysiikka7. Clean energy01 natural sciences010305 fluids & plasmaslaw.inventionIonECRISSputteringlawIonization0103 physical sciencesAtomic physicsplasma (kaasut)plasma
researchProduct

Impact of rolling conditions on the hydriding of grade 2 titanium welded tubes

2020

In this article, we study the impact of rolling conditions on the texture of the commercially pure titanium grade 2. In a previous work, NEOTISS in collaboration with ICB laboratory, shown that the texture highly influences the precipitation of hydrides in Titanium. In order to create different textures, Titanium sheets grade 2 are cold rolled asymmetrically and symmetrically with or without lubricant. The inverse pole figures and direct pole figures obtained allow us to deduce that symmetrical cold rolling does not change the grains orientation but generates a rotation of grains along c-axis (normal to basal plan). However, asymmetrical cold rolling leads to the formation of a new crystall…

010302 applied physicsMaterials scienceMetallurgychemistry.chemical_element02 engineering and technologyWeldingEngineering (General). Civil engineering (General)021001 nanoscience & nanotechnology01 natural scienceslaw.inventionchemistrylaw0103 physical sciencesTA1-20400210 nano-technologyTitaniumMATEC Web of Conferences
researchProduct

Correlations between density distributions, optical spectra, and ion species in a hydrogen plasma (invited)

2016

An experimental study of plasma distributions in a 2.45 GHz hydrogen discharge operated at 100 Hz repetition rate is presented. Ultrafast photography, time integrated visible light emission spectra, time resolved Balmer-alpha emission, time resolved Fulcher Band emission, ion species mass spectra, and time resolved ion species fraction measurements have been implemented as diagnostic tools in a broad range of plasma conditions. Results of plasma distributions and optical emissions correlated with H + , H + 2 , and H + 3 ion currents by using a Wien filter system with optical observation capability are reported. The magnetic field distribution and strength is found as the most critical facto…

010302 applied physicsMaterials scienceWien filterta114Hydrogenchemistry.chemical_elemention speciesPlasma01 natural sciences010305 fluids & plasmasIonchemistryPhysics::Plasma Physics0103 physical scienceshydrogen plasmaMass spectrumPlasma diagnosticsEmission spectrumAtomic physicsdensity distributionsoptical spectraInstrumentationVisible spectrumReview of Scientific Instruments
researchProduct

Evaluation and Comparison of Novel Precursors for Atomic Layer Deposition of Nb2O5 Thin Films

2012

Atomic layer deposition (ALD) of Nb2O5 thin films was studied using three novel precursors, namely, tBuN═Nb(NEt2)3, tBuN═Nb(NMeEt)3, and tamylN═Nb(OtBu)3. These precursors are liquid at room temperature, present good volatility, and are reactive toward both water and ozone as the oxygen sources. The deposition temperature was varied from 150 to 375 °C. ALD-type saturative growth modes were confirmed at 275 °C for tBuN═Nb(NEt2)3 and tBuN═Nb(NMeEt)3 together with both oxygen sources. Constant growth rate was observed between a temperature regions of 150 and 325 °C. By contrast, amylN═Nb(OtBu)3 exhibited limited thermal stability and thus a saturative growth mode was not achieved. All films we…

010302 applied physicsMaterials scienceta114General Chemical EngineeringAnalytical chemistrychemistry.chemical_element02 engineering and technologyGeneral Chemistry021001 nanoscience & nanotechnology01 natural sciencesOxygenAmorphous solidElastic recoil detectionAtomic layer depositionchemistry0103 physical sciencesMaterials ChemistryThermal stabilityThin film0210 nano-technologyta116Volatility (chemistry)High-κ dielectricChemistry of Materials
researchProduct

Atomic Layer Deposition of Osmium

2011

Growth of osmium thin films and nanoparticles by atomic layer deposition is described. The Os thin films were successfully grown between 325 and 375 °C using osmocene and molecular oxygen as precursors. The films consisted of only Os metal as osmium oxides were not detected in X-ray diffraction measurements. Also the impurity contents of oxygen, carbon, and hydrogen were less than 1 at % each at all deposition temperatures. The long nucleation delay of the Os process facilitates either Os nanoparticle or thin film deposition. However, after the nucleation delay of about 350 cycles the film growth proceeded linearly with increasing number of deposition cycles. Also conformal growth of Os thi…

010302 applied physicsMaterials scienceta114General Chemical EngineeringInorganic chemistryAnalytical chemistryNucleationchemistry.chemical_element02 engineering and technologyGeneral ChemistryChemical vapor deposition021001 nanoscience & nanotechnologyOsmocene01 natural scienceschemistry.chemical_compoundAtomic layer depositionCarbon filmchemistry0103 physical sciencesMaterials ChemistryDeposition (phase transition)OsmiumThin film0210 nano-technologyta116Chemistry of Materials
researchProduct

The effect of cavity tuning on oxygen beam currents of an A-ECR type 14 GHz electron cyclotron resonance ion source.

2016

The efficiency of the microwave-plasma coupling plays a significant role in the production of highly charged ion beams with electron cyclotron resonance ion sources (ECRISs). The coupling properties are affected by the mechanical design of the ion source plasma chamber and microwave launching system, as well as damping of the microwave electric field by the plasma. Several experiments attempting to optimize the microwave-plasma coupling characteristics by fine-tuning the frequency of the injected microwaves have been conducted with varying degrees of success. The inherent difficulty in interpretation of the frequency tuning results is that the effects of microwave coupling system and the ca…

010302 applied physicsMaterials scienceta114Highly charged ionPlasma01 natural sciencesElectron cyclotron resonanceIon sourcemicrowaves010305 fluids & plasmasIonmikroaallotPhysics::Plasma Physics0103 physical scienceselectron cyclotron resonance ion sourcesplasma chamberAtomic physicsInstrumentationBeam (structure)MicrowaveMicrowave cavityThe Review of scientific instruments
researchProduct

Kinetic instabilities in pulsed operation mode of a 14 GHz electron cyclotron resonance ion source

2016

The occurrence of kinetic plasma instabilities is studied in pulsed operation mode of a 14 GHz Aelectron cyclotron resonance type electron cyclotron resonance ion source. It is shown that the temporal delay between the plasma breakdown and the appearance of the instabilities is on the order of 10- 100 ms. The most important parameters affecting the delay are magnetic field strength and neutral gas pressure. It is demonstrated that kinetic instabilities limit the high charge state ion beam production in the unstable operating regime. peerReviewed

010302 applied physicsMaterials scienceta114Ion beamCyclotron resonancePlasma01 natural sciencesplasma electronsIon sourceElectron cyclotron resonanceFourier transform ion cyclotron resonance010305 fluids & plasmasMagnetic fieldpulsed operation modePhysics::Plasma Physics0103 physical scienceselectron cyclotron resonance ion sourceskinetic instabilitiesAtomic physicsInstrumentationIon cyclotron resonanceReview of Scientific Instruments
researchProduct

Recent improvements of the LPSC charge breeder

2017

International audience; PSC has developed the PHOENIX electron cyclotron resonance Charge Breeder since 2000. The performances have been improved over time acting on the 1+ and N+ beam optics, the base vacuum and the 1+ beam injection. A new objective is to update the booster design to enhance high charge state production and 1+ N+ efficiencies, reduce the co-extracted background beam and improve the ion source tunability. The first step, consisting in increasing the peak magnetic field at injection from 1.2 T to 1.6 T was implemented and significant improvement in 1+N+ efficiencies are reported: 12.9% of 23Na8+, 24.2% of 40Ar8+, 13.3% of 132Xe26+ and 13% of 133Cs26+. The next steps of the …

010302 applied physicsMaterials scienceta114Nuclear engineering[PHYS.PHYS.PHYS-ACC-PH]Physics [physics]/Physics [physics]/Accelerator Physics [physics.acc-ph]syklotronitCharge (physics)plasmatekniikka01 natural sciences7. Clean energy010305 fluids & plasmaselectron cyclotron resonanceBreeder (animal)0103 physical sciencesplasma
researchProduct

Photoelectron Emission from Metal Surfaces Induced by Radiation Emitted by a 14 GHz Electron Cyclotron Resonance Ion Source

2015

Photoelectron emission measurements have been performed using a room-temperature 14 GHz ECR ion source. It is shown that the photoelectron emission from Al, Cu, and stainless steel (SAE 304) surfaces, which are common plasma chamber materials, is predominantly caused by radiation emitted from plasma with energies between 8 eV and 1 keV. Characteristic X-ray emission and bremsstrahlung from plasma have a negligible contribution to the photoelectron emission. It is estimated from the measured data that the maximum conceivable photoelectron flux from plasma chamber walls is on the order of 10% of the estimated total electron losses from the plasma. peerReviewed

010302 applied physicsMaterials scienceta114Physics::Instrumentation and DetectorsAstrophysics::High Energy Astrophysical PhenomenaCyclotron resonanceBremsstrahlungFOS: Physical sciencesPlasmaElectronphotoelectron emissionRadiation01 natural sciences7. Clean energyElectron cyclotron resonanceIon sourcePhysics - Plasma Physics010305 fluids & plasmasPlasma Physics (physics.plasm-ph)Physics::Plasma Physics0103 physical scienceselectron cyclotron resonance ion sourcesPlasma diagnosticsAtomic physicsInstrumentation
researchProduct