Search results for "ABLATION"
showing 10 items of 322 documents
Release kinetics of early ischaemic biomarkers in a clinical model of acute myocardial infarction
2014
ObjectiveTo determine the release kinetics of different biomarkers with potential as novel early ischaemic biomarkers in patients with acute coronary syndrome (ACS); it is difficult to establish the detailed release kinetics in patients with acute myocardial infarction (AMI).MethodsWe analysed the release kinetics of soluble fms-like tyrosine kinase (sFlt-1), ischaemia modified albumin (IMA), and heart-type fatty acid binding protein (hFABP) in patients with hypertrophic obstructive cardiomyopathy who were undergoing transcoronary ablation of septal hypertrophy (TASH), a procedure mimicking AMI. Consecutive patients (n=21) undergoing TASH were included. Blood samples were collected before T…
Factors affecting basket catheter detection of real and phantom rotors in the atria: A computational study
2018
[EN] Anatomically based procedures to ablate atrial fibrillation (AF) are often successful in terminating paroxysmal AF. However, the ability to terminate persistent AF remains disappointing. New mechanistic approaches use multiple-electrode basket catheter mapping to localize and target AF drivers in the form of rotors but significant concerns remain about their accuracy. We aimed to evaluate how electrode-endocardium distance, far-field sources and inter-electrode distance affect the accuracy of localizing rotors. Sustained rotor activation of the atria was simulated numerically and mapped using a virtual basket catheter with varying electrode densities placed at different positions withi…
Sr-isotope analysis of speleothems by LA-MC-ICP-MS: High temporal resolution and fast data acquisition
2017
Speleothems are well established climate archives. A wide array of geochemical proxies, including stable isotopes and trace elements are present within speleothems to reconstruct past climate variability. However, each proxy is influenced by multiple factors, often hampering robust interpretation. Sr isotope ratios (87Sr/86Sr) can provide useful information about water residence time and water mixing in the host rock, as they are not fractionated during calcite precipitation. Laser ablation multi-collector-inductively coupled plasma mass spectrometry (LA-MC-ICP-MS) has rarely been used for determination of Sr isotope signatures in speleothems, as speleothems often do not possess appropriate…
Posterior cordotomy in bilateral vocal cord paralysis using monopolar microelectrodes and radiofrequency in 18 patient
2017
Endovenous ablation of refluxing saphenous and perforating veins.
2017
Abstract. Since the end of the nineties endovenous thermal ablation and more recently non-thermal, non-tumescent techniques have been developed and improved. Until now, because of their favourable side effect profile in conjunction to sustained efficacy, in many countries they already replaced high ligation and stripping in the treatment of refluxing saphenous veins as well as for treatment of perforators and selected tributaries. Now, studies and comparative trials are available with long-term follow-ups for most of the techniques, providing valid data on occlusion and reflux rates, side effect profiles, and health related quality of life.
Impact of monitoring on detection of arrhythmia recurrences in the ESC-EHRA EORP atrial fibrillation ablation long-term registry
2019
Abstract Aims Monitoring of patients after ablation had wide variations in the ESC-EHRA atrial fibrillation ablation long-term (AFA-LT) registry. We aimed to compare four different monitoring strategies after catheter AF ablation. Methods and results The ESC-EHRA AFA-LT registry included 3593 patients who underwent ablation. Arrhythmia monitoring during follow-up was performed by 12-lead electrocardiogram (ECG), Holter ECG, trans-telephonic ECG monitoring (TTMON), or an implanted cardiac monitoring (ICM) system. Patients were selected to a given monitoring group according to the most extensive ECG tool used in each of them. Comparison of the probability of freedom from recurrences was perfo…
Application of LA-ICP-MS as a rapid tool for analysis of elemental impurities in active pharmaceutical ingredients.
2014
The control of inorganic contaminants in active pharmaceutical ingredients has a significant role in the quality control of drug products. The concentration limits for metal residues in drug products have been defined by various regulatory guidelines. Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is a powerful and fast analytical technique for multi-elemental analysis. A disadvantage in using LA-ICP-MS method is the lack of matrix reference materials for validation and calibration purposes. This article focuses on the handling strategy of laboratory-made matrix calibration standards for the quantification of elemental impurities in an active pharmaceutical ingredie…
Visual performance of the Akreos Adapt AO intraocular lens in patients with different corneal profiles measured with an adaptive optics visual simula…
2012
AIMS: To evaluate the visual performance of an aberration-free intraocular lens (IOL) in patients with different corneal profiles using adaptive optics visual simulation. METHODS: A crx1 adaptive optics visual simulator was used to simulate the aberration pattern of an aberration-free IOL combined with five corneal profiles: virgin corneas and corneas with low and high myopic ablations and low and high hyperopic ablations. Ten eyes of 10 subjects were evaluated, and monocular distance visual acuity (VA) at 100%, 50% and 10% of contrast was measured. RESULTS: At 100% of contrast, no differences were found in VA values among virgin corneas, low and high myopic ablations and low hyperopic abla…
Depth of focus through different intraocular lenses in patients with different corneal profiles using adaptive optics visual simulation
2011
PURPOSE: To evaluate the depth of focus with monofocal intraocular lenses (IOLs) in patients with different corneal profiles using adaptive optics (AO) visual simulation. METHODS: An AO visual simulator (crx1, Imagine Eyes) was used to simulate the aberration pattern of three monofocal IOLs (Acrysof IQ SN60WF [Alcon Laboratories Inc]; Akreos Adapt AO [Bausch & Lomb]; and Triplato [AJL Ophthalmic]) of different optic designs. Five groups were considered: patients without any corneal refractive surgery (normal cornea group) and with prior low and high myopic and hyperopic ablations (low myopic ablation, high myopic ablation, low hyperopic ablation, and high hyperopic ablation groups). De…
Imaging findings of liver resection using a bipolar radiofrequency electrosurgical device—Initial observations
2010
Abstract Objective To assess contrast-enhanced US (CEUS), computed tomography (CT) and magnetic resonance (MR) imaging findings and serial changes of the treated area at follow-up in patients who underwent liver resection using a bipolar radiofrequency electrosurgical device. Methods Imaging findings of 27 patients with resected hepatocellular carcinomas (HCCs) ( n = 24) and metastases ( n = 3) (mean size: 2.6 cm), were retrospectively evaluated. Two readers assessed: the (a) presence, (b) thickness, (c) shape and (d) echogenicity (CEUS)/attenuation (CT)/signal intensity (MR imaging) at coagulated site and the (e) presence of residual tumor of the bipolar radiofrequency electrosurgical de…