Search results for "ACCURACY"
showing 10 items of 277 documents
Ein kalorimeter für hochenergetische elektronenstrahlen
1968
Abstract Construction details and experimental data are given for a total absorption calorimeter used for electron beams of several hundred MeV and for beam power up to 15 kW. In order to obtain high precision, precautions were taken to obtain very high heat insulation, specially by using a temperature controlled radiation shield. The heat loss of the 700 kg copper block corresponds to less than 10 −3 °C/h. Due to design calculations and confirmed by preliminary comparison tests with other beam monitors we consider the absolute accuracy to be 1% or probably better.
Study of the implementation of SPIF as a Reshaping strategy in terms of formability and accuracy performance
2022
The adaption of circular economy strategies has become increasingly necessary in current times. Researches need to be addressed on finding alternative processes or the modification of the existing processes in order to reprocess End-of-Life (EoL) components and consequently recover both materials and their functions. This research paper focuses on the use of single point incremental forming (SPIF) process for the Reshaping of sheet metal EoL components. Uniaxial and biaxial pre-straining was performed on AA5754 sheets to imitate an end-of-life component, and SPIF operations were carried out so as to obtain reshaped components. In previous works, the authors have proven the technical feasibi…
Accuracy and Transparency in Medical English Terminology. A Focus on Suffixes, with Particular Reference to the Use of -itis
2022
The prominent position of English in medical research makes term accuracy a very important feature in the successful transmission of meanings. Accuracy refers to the correctness of a term; it represents a very important feature of medical communication together with other principles, such as transparency. The latter is the possibility of immediately decoding the meaning of a term through an analysis of its surface form. Transparency does not always overlap with accuracy. In this respect, medical English terminology shows terms that, despite being transparent, are not used with the meaning an analysis of their form would suggest but are referred to different concepts. Starting from Tanchev’s…
Independent Validation of Sepsis Index for Sepsis Screening in the Emergency Department
2021
(1) Background: The early detection of sepsis is still challenging, and there is an urgent need for biomarkers that could identify patients at a high risk of developing it. We recently developed an index, namely the Sepsis Index (SI), based on the combination of two CBC parameters: monocyte distribution width (MDW) and mean monocyte volume (MMV). In this study, we sought to independently validate the performance of SI as a tool for the early detection of patients at a high risk of sepsis in the Emergency Department (ED). (2) Methods: We enrolled all consecutive patients attending the ED with a request of the CBC. MDW and MMV were measured on samples collected in K3-EDTA tubes on the UniCel …
The second round of Critical Assessment of Automated Structure Determination of Proteins by NMR: CASD-NMR-2013
2015
The second round of the community-wide initiative Critical Assessment of automated Structure Determination of Proteins by NMR (CASD-NMR-2013) comprised ten blind target datasets, consisting of unprocessed spectral data, assigned chemical shift lists and unassigned NOESY peak and RDC lists, that were made available in both curated (i.e. manually refined) or un-curated (i.e. automatically generated) form. Ten structure calculation programs, using fully automated protocols only, generated a total of 164 three-dimensional structures (entries) for the ten targets, sometimes using both curated and un-curated lists to generate multiple entries for a single target. The accuracy of the entries could…
Detection of RAS mutations in circulating tumor DNA: a new weapon in an old war against colorectal cancer. A systematic review of literature and meta…
2019
Background: Tissue evaluation for RAS (KRAS or NRAS) gene status in metastatic colorectal cancer (mCRC) patients represent the standard of care to establish the optimal therapeutic strategy. Unfortunately, tissue biopsy is hampered by several critical limitations due to its invasiveness, difficulty to access to disease site, patient’s compliance and, more recently, neoplastic tissue spatial and temporal heterogeneity. Methods: The authors performed a systematic literature review to identify available trials with paired matched tissue and ctDNA RAS gene status evaluation. The authors searched EMBASE, MEDLINE, Cochrane, www.ClinicalTrials.gov , and abstracts from international meetings. In to…
Polarimetry at MAMI
2013
Moller and Mott polarimeters have been compared concerning their measurement accuracy in a dedicated "spin dance" experiment. The results obtained with the different polarimeters at vastly different energy ranges were in agreement with each other within the given systematic uncertainties of a few percent. We discuss investigations of background conditions which may allow to reduce this important contribution to the uncertainties in the Mott polarimeter to a value below 1.0%.
Generalized differential transform method for nonlinear boundary value problem of fractional order
2015
Abstract In this paper the generalized differential transform method is applied to obtain an approximate solution of linear and nonlinear differential equation of fractional order with boundary conditions. Several numerical examples are considered and comparisons with the existing solution techniques are reported. Results show that the method is effective, easier to implement and very accurate when applied for the solution of fractional boundary values problems.
A normalized iterative Smoothed Particle Hydrodynamics method
2020
Abstract In this paper we investigate on a normalized iterative approach to improve the Smoothed Particle Hydrodynamics (SPH) estimate of a function. The method iterates on the residuals of an initial SPH approximation to obtain a more accurate solution. The iterative strategy preserves the matrix-free nature of the method, does not require changes on the kernel function and it is not affected by disordered data distribution. The iterative refinement is further improved by ensuring linear approximation order to the starting iterative values. We analyze the accuracy and the convergence of the method with the standard and normalized formulation giving evidence of the enhancements obtained wit…
Monotone cubic spline interpolation for functions with a strong gradient
2021
Abstract Spline interpolation has been used in several applications due to its favorable properties regarding smoothness and accuracy of the interpolant. However, when there exists a discontinuity or a steep gradient in the data, some artifacts can appear due to the Gibbs phenomenon. Also, preservation of data monotonicity is a requirement in some applications, and that property is not automatically verified by the interpolator. Hence, some additional techniques have to be incorporated so as to ensure monotonicity. The final interpolator is not actually a spline as C 2 regularity and monotonicity are not ensured at the same time. In this paper, we study sufficient conditions to obtain monot…